Modelling and comparison analysis of grid-connected DFIG-based wind farm in weak grid

被引:9
|
作者
Yan, Cai [1 ]
Yao, Wei [1 ]
Wen, Jianfeng [1 ]
Fang, Jiakun [1 ]
Ai, Xiaomeng [1 ]
Wen, Jinyu [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
关键词
stators; power generation control; wind power plants; rotors; asynchronous generators; shafts; eigenvalues and eigenfunctions; phase locked loops; grid-connected DFIG-based wind farm; weak grid; modelling comparison analysis; grid-connected double-fed induction generator; linear system analysis; PLL dynamics; eigenvalue analysis; FED INDUCTION GENERATOR; STABILITY ANALYSIS; IMPEDANCE-MODEL; DAMPING CONTROL; CONVERTERS; TURBINES;
D O I
10.1049/iet-rpg.2019.1382
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study proposes a generic method for modelling and comparison analysis of grid-connected double-fed induction generator (DFIG)-based wind farms in a weak grid. A detailed model of DFIG in a weak grid is established and used as a benchmark. Specifically, the detailed model consists of the mechanical part, generator part, rotor side converter, and phase-locked loop (PLL). Two simplified models of grid-connected DFIG-based wind farms in a weak grid are compared with the detailed model to investigate the mechanism of sub-synchronous oscillation (SSO) as well as the influential factors through linear system analysis. The first simplified model ignores shafting dynamics, stator flux dynamics, and PLL dynamics. The same assumptions are used in the latter, except that PLL dynamics are considered. Time-domain simulation and eigenvalue analysis are used to verify the accuracy of the simplified models. The block diagrams of the linearised system are derived based on the proposed model, and the oscillation mechanism is explained by linear system analysis. Through eigenvalue analysis and the root locus method, the influences of the parameters of the DFIG and its controllers on the system stability are identified and analysed.
引用
收藏
页码:2406 / 2415
页数:10
相关论文
共 50 条
  • [41] Impedance-Based Analysis of the Dynamic Stability for the Weak Grid-Connected DFIG during LVRT
    Liu, Ruikuo
    Yao, Jun
    Wang, Xuewei
    Sun, Peng
    Pei, Jinxin
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 969 - 974
  • [42] Modelling analysis of transient stability simulation with high penetration of grid-connected wind farms of DFIG type
    Shi, Libao
    Xu, Zheng
    Hao, Jin
    Ni, Yixin
    WIND ENERGY, 2007, 10 (04) : 303 - 320
  • [43] Analyzing the Dynamic Behavior of a DFIG-based Wind Farm under Sudden Grid Disturbances
    Chakraborty, A.
    Kumar, S.
    Tudu, B.
    Mandal, K. K.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2017), 2017, : 336 - 341
  • [44] Detailed Investigation and Performance Improvement of the Dynamic Behavior of Grid-Connected DFIG-Based Wind Turbines Under LVRT Conditions
    Alsmadi, Yazan M.
    Xu, Longya
    Blaabjerg, Frede
    Ortega, Alejandro J. Pina
    Abdelaziz, Almoataz Y.
    Wang, Aimeng
    Albataineh, Zaid
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) : 4795 - 4812
  • [45] DFIG with Grid-Connected Rotor for Wind Energy Conversion System
    David, Nicholas
    Aliprantis, Dionysios C.
    2013 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE (IEMDC), 2013, : 125 - 130
  • [46] An integral backstepping algorithm for a DFIG-based wind turbine connected to the undisturbed utility grid
    Boulaoutaq, El Mahfoud
    Kourchi, Mustapha
    Rachdy, Azeddine
    Test Engineering and Management, 2019, 81 (11-12): : 4446 - 4460
  • [47] Battery Connected DFIG Wind System Analysis for Strong/Weak Grid Scenarios
    Subburaj, Anitha Sarah
    Shamim, Nimat
    Bayne, Stephen B.
    PROCEEDINGS 2016 EIGHTH ANNUAL IEEE GREEN TECHNOLOGIES CONFERENCE (GREENTECH 2016), 2016, : 112 - 117
  • [48] Dynamic Stability Analysis of DFIG-based Wind Power System During Asymmetric Faults of Weak Grid
    Yao J.
    Sun P.
    Liu R.
    Fang X.
    Chi Y.
    Tian X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (21): : 7225 - 7236
  • [49] Investigation of Subsynchronous Oscillation in a DFIG-Based Wind Power Plant Connected to MTDC Grid
    Li, Haozhi
    Shair, Jan
    Zhang, Jiaqi
    Xie, Xiaorong
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2023, 38 (04) : 3222 - 3231
  • [50] DFIG-based Wind Turbines with Virtual Synchronous Control: Inertia Support in Weak Grid
    Wang, Shuo
    Hu, Jiabing
    Yuan, Xiaoming
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,