Modelling and comparison analysis of grid-connected DFIG-based wind farm in weak grid

被引:9
|
作者
Yan, Cai [1 ]
Yao, Wei [1 ]
Wen, Jianfeng [1 ]
Fang, Jiakun [1 ]
Ai, Xiaomeng [1 ]
Wen, Jinyu [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
关键词
stators; power generation control; wind power plants; rotors; asynchronous generators; shafts; eigenvalues and eigenfunctions; phase locked loops; grid-connected DFIG-based wind farm; weak grid; modelling comparison analysis; grid-connected double-fed induction generator; linear system analysis; PLL dynamics; eigenvalue analysis; FED INDUCTION GENERATOR; STABILITY ANALYSIS; IMPEDANCE-MODEL; DAMPING CONTROL; CONVERTERS; TURBINES;
D O I
10.1049/iet-rpg.2019.1382
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study proposes a generic method for modelling and comparison analysis of grid-connected double-fed induction generator (DFIG)-based wind farms in a weak grid. A detailed model of DFIG in a weak grid is established and used as a benchmark. Specifically, the detailed model consists of the mechanical part, generator part, rotor side converter, and phase-locked loop (PLL). Two simplified models of grid-connected DFIG-based wind farms in a weak grid are compared with the detailed model to investigate the mechanism of sub-synchronous oscillation (SSO) as well as the influential factors through linear system analysis. The first simplified model ignores shafting dynamics, stator flux dynamics, and PLL dynamics. The same assumptions are used in the latter, except that PLL dynamics are considered. Time-domain simulation and eigenvalue analysis are used to verify the accuracy of the simplified models. The block diagrams of the linearised system are derived based on the proposed model, and the oscillation mechanism is explained by linear system analysis. Through eigenvalue analysis and the root locus method, the influences of the parameters of the DFIG and its controllers on the system stability are identified and analysed.
引用
收藏
页码:2406 / 2415
页数:10
相关论文
共 50 条
  • [21] Dynamic Stability Analysis of a DFIG-Based Offshore Wind Farm Connected to a Power Grid Through an HVDC Link
    Wang, Li
    Wang, Kuo-Hua
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (03) : 1501 - 1510
  • [22] Multiple machine representation of DFIG-based grid-connected wind farms for SSR studies.
    Atayde, S.
    Chandra, A.
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011, : 1468 - 1473
  • [23] Stability Analysis of DFIG-based Wind Turbines Based on Hybrid Control in Weak Grid
    Xie Z.
    Xu K.
    Gao X.
    Yang S.
    Zhang X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (20): : 7426 - 7438
  • [24] Cooperative Rotor-Side SMES and Transient Control for Improving the LVRT Capability of Grid-Connected DFIG-Based Wind Farm
    Xiao, Xian-Yong
    Yang, Ruo-Huan
    Zheng, Zi-Xuan
    Wang, Ying
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
  • [25] Research on Mechanism and Damping Control Strategy of DFIG-Based Wind Farm Grid-Connected System SSR Based on the Complex Torque Method
    Peng, Xiaotao
    Chen, Renjie
    Zhou, Jicheng
    Qin, Shiyao
    Bi, Ran
    Sun, Haishun
    ELECTRONICS, 2021, 10 (14)
  • [26] Transient Stability Mechanism of DFIG Wind farm and Grid-connected Power System
    Lin, Li
    Zhao, Huilong
    Lan, Tao
    Wang, Qian
    Zeng, Jie
    2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [27] Improved Control of Grid-connected DFIG-based Wind Turbine using Proportional-Resonant Regulators during Unbalanced Grid
    El Karkri, Yassir
    Rey-Boue, Alexis B.
    El Moussaoui, Hassan
    Stoeckl, Johannes
    Strasser, Thomas, I
    ENERGIES, 2019, 12 (21)
  • [28] Operation and control of a grid-connected DFIG-based wind turbine with series grid-side converter during network unbalance
    Yong Liao
    Hui Li
    Jun Yao
    Kai Zhuang
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (01) : 228 - 236
  • [29] Control strategy for suppressing the shafting oscillation of the grid-connected DFIG-based wind power generation system
    Yao, Jun
    Zhang, Tian
    Wang, Xuewei
    Zeng, Deyin
    Sun, Peng
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2019, 29 (09):
  • [30] Indirect Fuzzy Adaptive Synchronization and Control of a Grid-Connected DFIG-Based WECS
    Labdai, S.
    Alibi, A.
    Chrifi-Alaoui, L.
    Drid, S.
    Hemici, B.
    Nezli, L.
    2020 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND DIAGNOSIS (ICCAD), 2020, : 283 - 288