Modelling and comparison analysis of grid-connected DFIG-based wind farm in weak grid

被引:9
|
作者
Yan, Cai [1 ]
Yao, Wei [1 ]
Wen, Jianfeng [1 ]
Fang, Jiakun [1 ]
Ai, Xiaomeng [1 ]
Wen, Jinyu [1 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Elect & Elect Engn, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
关键词
stators; power generation control; wind power plants; rotors; asynchronous generators; shafts; eigenvalues and eigenfunctions; phase locked loops; grid-connected DFIG-based wind farm; weak grid; modelling comparison analysis; grid-connected double-fed induction generator; linear system analysis; PLL dynamics; eigenvalue analysis; FED INDUCTION GENERATOR; STABILITY ANALYSIS; IMPEDANCE-MODEL; DAMPING CONTROL; CONVERTERS; TURBINES;
D O I
10.1049/iet-rpg.2019.1382
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study proposes a generic method for modelling and comparison analysis of grid-connected double-fed induction generator (DFIG)-based wind farms in a weak grid. A detailed model of DFIG in a weak grid is established and used as a benchmark. Specifically, the detailed model consists of the mechanical part, generator part, rotor side converter, and phase-locked loop (PLL). Two simplified models of grid-connected DFIG-based wind farms in a weak grid are compared with the detailed model to investigate the mechanism of sub-synchronous oscillation (SSO) as well as the influential factors through linear system analysis. The first simplified model ignores shafting dynamics, stator flux dynamics, and PLL dynamics. The same assumptions are used in the latter, except that PLL dynamics are considered. Time-domain simulation and eigenvalue analysis are used to verify the accuracy of the simplified models. The block diagrams of the linearised system are derived based on the proposed model, and the oscillation mechanism is explained by linear system analysis. Through eigenvalue analysis and the root locus method, the influences of the parameters of the DFIG and its controllers on the system stability are identified and analysed.
引用
收藏
页码:2406 / 2415
页数:10
相关论文
共 50 条
  • [31] Fault Analysis of PI and Fuzzy-Logic-Controlled DFIG-based Grid-Connected Wind Energy Conversion System
    Ganthia B.P.
    Barik S.K.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (02) : 415 - 437
  • [32] Application of SFCL to Improve the Transient Voltage Stability of Grid-Connected Wind Farm with DFIG during Grid Faults
    Ou, Ran
    Xiao, Xian Yong
    Zou, Zhi Ce
    Li, Chang Song
    Wu, Dan Yue
    2015 IEEE International Conference on Applied Superconductivity and Electromagnetic Devices (ASEMD), 2015, : 240 - 241
  • [33] An emotional control approach to grid-connected DFIG based wind turbine
    Velpula, Manikanta Raju
    Kona, Hanumath Phani Shree
    INTERNATIONAL JOURNAL OF DYNAMICS AND CONTROL, 2023, 12 (08) : 3048 - 3063
  • [34] Active Power Limit for DFIG-Based Wind Turbine under Weak Grid
    Guo, Xiang
    Zou, Xudong
    Jiang, Congcong
    Zhu, Donghai
    Yang, Yihang
    Peng, Li
    Lin, Xinchun
    2019 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2019, : 968 - 973
  • [35] Harmonic Analysis of the Grid-connected Wind Farm by Simulation and Calculation
    Liu, Tingting
    Wen, Jun
    Fu, Xixi
    Ji, Cheng
    Han, Minxiao
    PROCEEDINGS OF 2014 IEEE WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS (WARTIA), 2014, : 1342 - 1345
  • [36] Synchronizing Stability of DFIG-based Wind Turbines Attached to Weak AC Grid
    Hu, Qi
    Hu, Jiabing
    Yuan, Hao
    Tang, Haiyan
    Li, Yan
    2014 17TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2014, : 2618 - 2624
  • [37] Control for grid-connected DFIG-based wind energy system using adaptive neuro-fuzzy technique
    Shihabudheen, K. V.
    Raju, S. Krishnama
    Pillai, G. N.
    INTERNATIONAL TRANSACTIONS ON ELECTRICAL ENERGY SYSTEMS, 2018, 28 (05):
  • [38] A robust power control strategy to enhance LVRT capability of grid-connected DFIG-based wind energy systems
    Ardjoun, Sid Ahmed El Mehdi
    Denai, Mouloud
    Abid, Mohamed
    WIND ENERGY, 2019, 22 (06) : 834 - 847
  • [39] Analysis of influencing factors of subsynchronous oscillation caused by a DFIG-based wind farm via the VSC-HVDC grid-connected system based on a data driven method
    Xu X.
    Bian X.
    Zhang Q.
    Chang X.
    Huang R.
    Sun K.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (21): : 80 - 87
  • [40] Grid-connected Wide-band Oscillation Analysis of DFIG-based Wind Turbine Based on Polynomial Approximation of All Eigenvalue Trajectories
    Shen D.
    Wang G.
    Wu H.
    Gan D.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2023, 47 (11): : 39 - 49