A rapid, simple, specific liquid chromatographic-electrospray mass spectrometry method for the determination of finasteride in human plasma and its application to pharmacokinetic study

被引:16
|
作者
Guo, Fanc-Qiu
Huang, Lan-Fang [1 ]
Wong, Kin Ping
Dai, Yun-Hui
Li, Ya-Wen
Liang, Yi-Zeng
Huang, Ke-Long
Zhong, Ke-Jun
Wu, Ming-Han
机构
[1] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Peoples R China
[2] Calif State Univ Fresno, Dept Biol, Coll Sci & Math, Fresno, CA 93740 USA
[3] Changde Cigarette Factory, Ctr Tech, Changde 415000, Peoples R China
关键词
finasteride; liquid chromatography-mass spectrometry (LC-MS); electrospray ionization (ESI); pharmacokinetic;
D O I
10.1016/j.jpba.2006.10.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, accurate, sensitive, selective and reliable method using reversed-phase high-performance liquid chromatography-mass spectrometry coupling with an electrospray ionization interface was developed and validated for the determination of finasteride in human plasma. After deprotienation with acetonitrile, centrifugation, evaporation to dryness and dissolving in mobile phase, satisfactory separation was achieved on a Hypersil-Keystone C(18) reversed-phase column using a mobile phase consisting of acetonitrile-water (46:54, v/v), 0.1% acetic acid and 0.1% trifluoracetic acid. Carbamazepine (IS) was used as internal standard. This method involved the use of the [M+H](+) ions of finasteride and IS at m/z 373 and 237 with the selective ion monitoring (SIM) mode. The calibration curve was linear in the range of 0.2-120 ng ml(-1). The limit of quantification for finasteride in plasma was 0.2 ng ml(-1) with good accuracy and precision. The intra-assay precision and accuracy were in the range of 2.1-11.2% and -1.3% to 8.5%, respectively. The inter-assay precision and accuracy were in the order of 3.4-12.1% and -1.5% to 11.5%, respectively. The mean sample extract recoveries of the method were higher than 85% and 74% for finasteride and internal standard (IS), respectively. The assay has been successfully used to estimate the pharmacokinetics of finasteride after oral administration of a 5 mg tablet of finasteride to 24 healthy volunteers. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1507 / 1513
页数:7
相关论文
共 50 条
  • [21] Rapid Determination of Ranitidine in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Clinical Pharmacokinetic Study
    Zhang Chao
    Wang Lu
    Guan Xin
    Fawcett, J. Paul
    Zhao Li-mei
    Sun Yan-tong
    Gu Jing-kai
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2010, 26 (06) : 910 - 914
  • [22] A Simple Liquid Chromatographic Method for the Determination of Tenofovir in Rat Plasma and Its Application to Pharmacokinetic Studies
    Ravi, P. R.
    Joseph, S.
    Avula, U. S. R.
    Anthireddy, S.
    ACTA CHROMATOGRAPHICA, 2015, 27 (04) : 597 - 612
  • [23] Simple liquid chromatographic method for the determination of physostigmine and its metabolite eseroline in rat plasma: application to a pharmacokinetic study
    Zhao, B
    Moochhala, SM
    Chaw, CS
    Yang, YY
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (02): : 323 - 329
  • [24] Rapid and highly sensitive liquid chromatography/electrospray ionization tandem mass spectrometry method for the quantitation of buspirone in human plasma: application to a pharmacokinetic study
    Cho, SH
    Lee, HW
    Im, HT
    Park, WS
    Choi, YW
    Rew, JH
    Lee, KT
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (08) : 1293 - 1298
  • [25] Determination of tamsulosin in human plasma by liquid chromatography/tandem mass spectrometry and its application to a pharmacokinetic study
    Choi, Chang-Ik
    Lee, Hye-In
    Bae, Jung-Woo
    Lee, Yun-Jeong
    Byeon, Ji-Yeong
    Jang, Choon-Gon
    Lee, Seok-Yong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 909 : 65 - 69
  • [26] Determination of lomerizine in human plasma by liquid chromatography/tandem mass spectrometry and its application to a pharmacokinetic study
    Ren, Yulong
    Liu, Tianshun
    Song, Guoxin
    Hu, Yaoming
    Liang, Jianying
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 947 : 96 - 102
  • [27] A simple and sensitive liquid chromatographic technique for the determination of cefotetan disodium in human plasma and its application in a pharmacokinetic study
    Yani Liu
    Jiangeng Huang
    Jinmei Liu
    Lin Ma
    Yongning Lv
    Shaojun Shi
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2012, 32 : 779 - 784
  • [28] A simple and sensitive liquid chromatographic technique for the determination of cefotetan disodium in human plasma and its application in a pharmacokinetic study
    Liu, Yani
    Huang, Jiangeng
    Liu, Jinmei
    Ma, Lin
    Lv, Yongning
    Shi, Shaojun
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2012, 32 (05) : 779 - 784
  • [29] Liquid chromatography-electrospray ionisation mass spectrometry method for the determination of escitalopram in human plasma and its application in bioequivalence study
    Singh, SS
    Shah, H
    Gupta, S
    Jain, M
    Sharma, K
    Thakkar, P
    Shah, R
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 811 (02): : 209 - 215
  • [30] Liquid chromatography-mass spectrometry method for the determination of venlafaxine in human plasma and application to a pharmacokinetic study
    Zhang Wei
    Xiang Bing-ren
    Wang Cai-yun
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (03) : 266 - 272