A rapid, simple, specific liquid chromatographic-electrospray mass spectrometry method for the determination of finasteride in human plasma and its application to pharmacokinetic study

被引:16
|
作者
Guo, Fanc-Qiu
Huang, Lan-Fang [1 ]
Wong, Kin Ping
Dai, Yun-Hui
Li, Ya-Wen
Liang, Yi-Zeng
Huang, Ke-Long
Zhong, Ke-Jun
Wu, Ming-Han
机构
[1] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Peoples R China
[2] Calif State Univ Fresno, Dept Biol, Coll Sci & Math, Fresno, CA 93740 USA
[3] Changde Cigarette Factory, Ctr Tech, Changde 415000, Peoples R China
关键词
finasteride; liquid chromatography-mass spectrometry (LC-MS); electrospray ionization (ESI); pharmacokinetic;
D O I
10.1016/j.jpba.2006.10.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, accurate, sensitive, selective and reliable method using reversed-phase high-performance liquid chromatography-mass spectrometry coupling with an electrospray ionization interface was developed and validated for the determination of finasteride in human plasma. After deprotienation with acetonitrile, centrifugation, evaporation to dryness and dissolving in mobile phase, satisfactory separation was achieved on a Hypersil-Keystone C(18) reversed-phase column using a mobile phase consisting of acetonitrile-water (46:54, v/v), 0.1% acetic acid and 0.1% trifluoracetic acid. Carbamazepine (IS) was used as internal standard. This method involved the use of the [M+H](+) ions of finasteride and IS at m/z 373 and 237 with the selective ion monitoring (SIM) mode. The calibration curve was linear in the range of 0.2-120 ng ml(-1). The limit of quantification for finasteride in plasma was 0.2 ng ml(-1) with good accuracy and precision. The intra-assay precision and accuracy were in the range of 2.1-11.2% and -1.3% to 8.5%, respectively. The inter-assay precision and accuracy were in the order of 3.4-12.1% and -1.5% to 11.5%, respectively. The mean sample extract recoveries of the method were higher than 85% and 74% for finasteride and internal standard (IS), respectively. The assay has been successfully used to estimate the pharmacokinetics of finasteride after oral administration of a 5 mg tablet of finasteride to 24 healthy volunteers. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:1507 / 1513
页数:7
相关论文
共 50 条
  • [31] Liquid chromatographic/mass spectrometry assay of triptolide in dog plasma and its application to pharmacokinetic study
    Shao, F
    Wang, GJ
    Sun, FG
    Xie, HT
    Li, H
    Liang, Y
    Zhang, R
    Zhu, XY
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (02) : 341 - 346
  • [32] A simple high-performance liquid chromatographic method for the determination of acyclovir in human plasma and application to a pharmacokinetic study
    Yu, Liyan
    Xiang, Bingren
    Zhan, Ying
    ARZNEIMITTEL-FORSCHUNG-DRUG RESEARCH, 2008, 58 (04): : 199 - 202
  • [33] Liquid chromatographic/mass spectrometry assay of bromotetrandrine in rat plasma and its application to pharmacokinetic study
    Song, Naining
    Zhang, Shaoyu
    Li, Quansheng
    Liu, Changxiao
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (06) : 623 - 629
  • [34] Rapid and sensitive determination of donepezil in human plasma by liquid chromatography/tandem mass spectrometry: application to a pharmacokinetic study
    Xie, Zhiyong
    Liao, Qiongfeng
    Xu, Xinjun
    Yao, Meicun
    Wan, Jinzhi
    Liu, Dan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (21) : 3193 - 3198
  • [35] Rapid determination of apixaban concentration in human plasma by liquid chromatography/tandem mass spectrometry: Application to pharmacokinetic study
    Delavenne, Xavier
    Mismetti, Patrick
    Basset, Thierry
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 : 150 - 153
  • [36] Rapid Determination of Imatinib in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry: Application to a Pharmacokinetic Study
    Yang, Jeong Soo
    Cho, Eun Gi
    Huh, Wooseong
    Ko, Jae-Wook
    Jung, Jin Ah
    Lee, Soo-Youn
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (08) : 2425 - 2430
  • [37] Quantitative determination of azithromycin in human plasma by ultra performance liquid chromatography-electrospray ionization mass spectrometry and its application in a pharmacokinetic study
    Chen, Lingyun
    Qin, Feng
    Ma, Yuanyuan
    Li, Famei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 255 - 261
  • [38] Determination of lovastatin in human plasma by ultra-performance liquid chromatography - electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study
    Yuan, Haiyan
    Wang, Feng
    Tu, Jiying
    Peng, Wenxing
    Li, Huande
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) : 808 - 813
  • [39] Simple and rapid method determination for metformin in human plasma using high performance liquid chromatography tandem mass spectrometry: Application to pharmacokinetic studies
    Sipoli Marques, Marlice A.
    Soares, Alcenir de Souza
    Pinto, Olivia Woyames
    Werneck Barroso, Pedro Tupinamba
    Pinto, Douglas Pereira
    Ferreira-Filho, Milton
    Werneck-Barroso, Eduardo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 308 - 316
  • [40] A sensitive, rapid and specific determination of midazolam in human plasma and saliva by liquid chromatography/electrospray mass spectrometry
    Quintela, O
    Cruz, A
    Concheiro, M
    de Castro, A
    López-Rivadulla, M
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2004, 18 (24) : 2976 - 2982