Highly sensitive chemiluminescence flow-injection detection of the red tide phytoplankton Heterosigma carterae

被引:17
|
作者
Asai, R [1 ]
Matsukawa, R [1 ]
Ikebukuro, K [1 ]
Karube, I [1 ]
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
关键词
chemiluminescence; flow injection analysis; red tide phytoplankton; superoxide; hydrogen peroxide; Heterosigma carterae;
D O I
10.1016/S0003-2670(99)00145-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two chemiluminescent how-injection analysis systems for the detection of the red tide Phytoplankton Heterosigma carterae (formerly known as Heterosigma akashiwo) have been developed. In one system, the superoxide (O-2(-)) released by H. carterae reacts with 2-methyl-6-(p-methoxyphenyl)-3,7-dihydroimidazo[1,2-a]-pyrazin-3-one (MCLA), a superoxide specific probe. In the other system, the hydrogen peroxide released by H. carterae reacts with luminol catalyzed by Arthromyces ramosus peroxidase (ARP). The chemiluminescence is detected by a photomultiplier tube. This system is capable of the rapid determination of H. carterae; the time required for one measurement cycle is ca. 2 min using MCLA-dependant luminescence or 1 min in luminol/ARP luminescence. A linear response was observed from 10(2) to 10(5) cells ml(-1) H. carterae. Several other species of phytoplankton gave no response using this system. The detection limit of this method is suitable for detecting H. carterae in the early stage of red tide formation. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [41] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [42] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    TALANTA, 2007, 71 (02) : 900 - 905
  • [43] Chemiluminescence and bioluminescence monitoring - A flow-injection approach
    Nabi, A
    Yaqoob, M
    Anwar, M
    LABORATORY ROBOTICS AND AUTOMATION, 1999, 11 (02) : 91 - 96
  • [44] Flow-injection chemiluminescence determination of haemoglobin in the blood
    Traore, Zoumana Sekou
    Shah, Syed Mazhar
    Su, Xingguang
    LUMINESCENCE, 2013, 28 (01) : 56 - 62
  • [45] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao, Zhi-Ming
    Zou, Ping
    Chen, Mei
    Xiu, Fu-Rong
    Chen, Yu-Lin
    Hong, Ke-Jun
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2008, 28 (02): : 269 - 272
  • [46] A Flow-Injection Chemiluminescence Determination of Formaldehyde in Textiles
    Kanwal, Shamsa
    Ma, Qiang
    Fu, Xiaohong
    Yuan, Pingfan
    Su, Xingguang
    SPECTROSCOPY LETTERS, 2010, 43 (02) : 84 - 90
  • [47] Determination of diethylstilboestrol by flow-injection chemiluminescence immunoassay
    Wang, S.
    Li, L.
    Liang, Y.
    Zhao, Y.
    LUMINESCENCE, 2008, 23 (02) : 100 - 100
  • [48] Flow-injection chemiluminescence analysis of cloperastione hydrochloride
    Sun, Shuwen
    Lu, Jiuru
    ANALYTICAL LETTERS, 2006, 39 (12) : 2475 - 2481
  • [49] N-bromosuccinimide-fluorescein based sensitive flow-injection chemiluminescence determination of phenformin
    Wang, ZP
    Zhang, ZJ
    Fu, ZF
    Fang, LQ
    Zhang, X
    ANALYTICAL SCIENCES, 2004, 20 (02) : 319 - 323
  • [50] A rapid and sensitive method for the determination of dibutyl phthalate in wine by flow-injection chemiluminescence analysis
    Guo, Jie
    Luo, Kai
    Chen, Donghua
    Tan, Xijuan
    Song, Zhenghua
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2013, 31 (02) : 226 - 231