Highly sensitive chemiluminescence flow-injection detection of the red tide phytoplankton Heterosigma carterae

被引:17
|
作者
Asai, R [1 ]
Matsukawa, R [1 ]
Ikebukuro, K [1 ]
Karube, I [1 ]
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
关键词
chemiluminescence; flow injection analysis; red tide phytoplankton; superoxide; hydrogen peroxide; Heterosigma carterae;
D O I
10.1016/S0003-2670(99)00145-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two chemiluminescent how-injection analysis systems for the detection of the red tide Phytoplankton Heterosigma carterae (formerly known as Heterosigma akashiwo) have been developed. In one system, the superoxide (O-2(-)) released by H. carterae reacts with 2-methyl-6-(p-methoxyphenyl)-3,7-dihydroimidazo[1,2-a]-pyrazin-3-one (MCLA), a superoxide specific probe. In the other system, the hydrogen peroxide released by H. carterae reacts with luminol catalyzed by Arthromyces ramosus peroxidase (ARP). The chemiluminescence is detected by a photomultiplier tube. This system is capable of the rapid determination of H. carterae; the time required for one measurement cycle is ca. 2 min using MCLA-dependant luminescence or 1 min in luminol/ARP luminescence. A linear response was observed from 10(2) to 10(5) cells ml(-1) H. carterae. Several other species of phytoplankton gave no response using this system. The detection limit of this method is suitable for detecting H. carterae in the early stage of red tide formation. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [31] Flow injection chemiluminescence analysis for highly sensitive determination of noscapine
    Zhuang, YF
    Cai, XL
    Yu, JS
    Ju, HX
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2004, 162 (2-3) : 457 - 462
  • [32] Photodegradation and flow-injection determination of simetryn herbicide by luminol chemiluminescence detection
    Waseem, Amir
    Yaqoob, Mohammad
    Nabi, Abdul
    ANALYTICAL SCIENCES, 2008, 24 (08) : 979 - 983
  • [33] DETERMINATION OF TRACE AMOUNTS OF UREA BY USING FLOW-INJECTION WITH CHEMILUMINESCENCE DETECTION
    HU, XC
    TAKENAKA, N
    KITANO, M
    BANDOW, H
    MAEDA, Y
    HATTORI, M
    ANALYST, 1994, 119 (08) : 1829 - 1833
  • [34] FLOW-INJECTION ENZYME-IMMUNOASSAY OF HAPTENS WITH ENHANCED CHEMILUMINESCENCE DETECTION
    AREFYEV, AA
    VLASENKO, SB
    EREMIN, SA
    OSIPOV, AP
    EGOROV, AM
    ANALYTICA CHIMICA ACTA, 1990, 237 (02) : 285 - 289
  • [35] Photodegradation and Flow-Injection Determination of Simetryn Herbicide by Luminol Chemiluminescence Detection
    Amir Waseem
    Mohammad Yaqoob
    Abdul Nabi
    Analytical Sciences, 2008, 24 : 979 - 983
  • [36] CHEMILUMINESCENCE DETECTION OF SODIUM-NITROPRUSSIDE USING FLOW-INJECTION ANALYSIS
    ALWARTHAN, AA
    TALANTA, 1994, 41 (10) : 1683 - 1688
  • [37] On-line treatments for highly sensitive flow-injection analysis
    Oshima, M
    BUNSEKI KAGAKU, 1999, 48 (03) : 315 - 327
  • [38] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao Zhi-ming
    Zou Ping
    Chen Mei
    Xiu Fu-rong
    Chen Yu-lin
    Hong Ke-jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (02) : 269 - 272
  • [39] Sensitive determination of ketoprofen using flow injection with chemiluminescence detection
    Zhuang, Yafeng
    Song, Hengli
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (03) : 824 - 828
  • [40] Determination of isoniazid by flow-injection chemiluminescence analysis
    Qu, P
    Li, BX
    Zhang, ZJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (05) : 665 - 667