Highly sensitive chemiluminescence flow-injection detection of the red tide phytoplankton Heterosigma carterae

被引:17
|
作者
Asai, R [1 ]
Matsukawa, R [1 ]
Ikebukuro, K [1 ]
Karube, I [1 ]
机构
[1] Univ Tokyo, Adv Sci & Technol Res Ctr, Meguro Ku, Tokyo 1538904, Japan
关键词
chemiluminescence; flow injection analysis; red tide phytoplankton; superoxide; hydrogen peroxide; Heterosigma carterae;
D O I
10.1016/S0003-2670(99)00145-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two chemiluminescent how-injection analysis systems for the detection of the red tide Phytoplankton Heterosigma carterae (formerly known as Heterosigma akashiwo) have been developed. In one system, the superoxide (O-2(-)) released by H. carterae reacts with 2-methyl-6-(p-methoxyphenyl)-3,7-dihydroimidazo[1,2-a]-pyrazin-3-one (MCLA), a superoxide specific probe. In the other system, the hydrogen peroxide released by H. carterae reacts with luminol catalyzed by Arthromyces ramosus peroxidase (ARP). The chemiluminescence is detected by a photomultiplier tube. This system is capable of the rapid determination of H. carterae; the time required for one measurement cycle is ca. 2 min using MCLA-dependant luminescence or 1 min in luminol/ARP luminescence. A linear response was observed from 10(2) to 10(5) cells ml(-1) H. carterae. Several other species of phytoplankton gave no response using this system. The detection limit of this method is suitable for detecting H. carterae in the early stage of red tide formation. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [1] Chemiluminescence flow-injection system for rapid detection of red tide phytoplankton, Chattonella antiqua
    Asai, R
    Matsukawa, R
    Ikebukuro, K
    Karube, I
    ANALYTICAL LETTERS, 1998, 31 (13) : 2279 - 2288
  • [2] Highly Sensitive Flow-Injection Chemiluminescence Detection of Carbonyl Compounds in Wine Samples
    Kanwal, Shamsa
    Fu, Xiaohong
    Su, Xingguang
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 4 - 11
  • [3] Highly sensitive flow-injection chemiluminescence determination of pyrogallol compounds
    Kanwal, Shamsa
    Fu, Xiaohong
    Su, Xingguang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2009, 74 (05) : 1046 - 1049
  • [4] A highly sensitive flow-injection chemiluminescence method for the determination of hydrazine in water
    Zhang, J.
    Yang, M.
    LUMINESCENCE, 2008, 23 (02) : 111 - 111
  • [5] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [6] CHEMILUMINESCENCE DETECTION OF RED TIDE PHYTOPLANKTON CHATTONELLA-MARINA
    LEE, TY
    GOTOH, N
    NIKI, E
    YOKOYAMA, K
    TSUZUKI, M
    TAKEUCHI, T
    KARUBE, I
    ANALYTICAL CHEMISTRY, 1995, 67 (01) : 225 - 228
  • [7] Flow-injection with chemiluminescence detection for the determination of iproniazid
    Alonso, MCS
    Zamora, LL
    Calatayud, JM
    ANALYTICA CHIMICA ACTA, 2001, 437 (02) : 225 - 231
  • [8] Highly sensitive flow-injection immunoassay system for rapid detection of bacteria
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    ANALYTICA CHIMICA ACTA, 1999, 399 (1-2) : 99 - 108
  • [9] Development of a highly sensitive chemiluminescence flow-injection analysis sensor for phosphate-ion detection using maltose phosphorylase
    Nakamura, H
    Hasegawa, M
    Nomura, Y
    Arikawa, Y
    Matsukawa, R
    Ikebukuro, K
    Karube, I
    JOURNAL OF BIOTECHNOLOGY, 1999, 75 (2-3) : 127 - 133
  • [10] DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION
    ABBOTT, RW
    TOWNSHEND, A
    GILL, R
    ANALYST, 1986, 111 (06) : 635 - 640