Development of a colorimetric microfluidic pH sensor for autonomous seawater measurements

被引:62
|
作者
Rerolle, Victorie M. C. [1 ]
Floquet, Cedric F. A. [2 ]
Harris, Andy J. K. [2 ]
Mowlem, Matt C. [2 ]
Bellerby, Richard R. G. J. [3 ,4 ,5 ]
Achterberg, Eric P. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
[2] Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
[3] Norwegian Inst Water Res, N-5006 Bergen, Norway
[4] Uni Bjerknes Ctr, Uni Res AS, N-5007 Bergen, Norway
[5] Univ Bergen, Inst Phys, N-5007 Bergen, Norway
基金
英国自然环境研究理事会;
关键词
pH; Colorimetry; Sensor development; Microfluidic pH sensor; LED; Autonomous; M-CRESOL PURPLE; IN-SITU; SPECTROPHOTOMETRIC DETERMINATION; OCEAN-ACIDIFICATION; INORGANIC CARBON; THYMOL BLUE; SEA-WATER; TEMPERATURE; DEPENDENCE; CO2;
D O I
10.1016/j.aca.2013.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High quality carbonate chemistry measurements are required in order to fully understand the dynamics of the oceanic carbonate system. Seawater pH data with good spatial and temporal coverage are particularly critical to apprehend ocean acidification phenomena and their consequences. There is a growing need for autonomous in situ instruments that measure pH on remote platforms. Our aim is to develop an accurate and precise autonomous in situ pH sensor for long term deployment on remote platforms. The widely used spectrophotometric pH technique is capable of the required high-quality measurements. We report a key step towards the miniaturization of a colorimetric pH sensor with the successful implementation of a simple microfluidic design with low reagent consumption. The system is particularly adapted to shipboard deployment: high quality data was obtained over a period of more than a month during a shipboard deployment in northwest European shelf waters, and less than 30 mL of indicator was consumed. The system featured a short term precision of 0.001 pH (n = 20) and an accuracy within the range of a certified Tris buffer (0.004 pH). The quality of the pH system measurements have been checked using various approaches: measurements of certified Tris buffer, measurement of certified seawater for DIC and TA, comparison of measured pH against calculated pH from pCO(2), DIC and TA during the cruise in northwest European shelf waters. All showed that our measurements were of high quality. The measurements were made close to in situ temperature (+0.2 degrees C) in a sampling chamber which had a continuous flow of the ship's underway seawater supply. The optical set up was robust and relatively small due to the use of an USB mini-spectrometer, a custom made polymeric flow cell and an LED light source. The use of a three wavelength LED with detection that integrated power across the whole of each LED output spectrum indicated that low wavelength resolution detectors can be used instead of the current USB mini spectrophotometer. Artefacts due to the polychromatic light source and inhomogeneity in the absorption cell are shown to have a negligible impact on the data quality. The next step in the miniaturization of the sensor will be the incorporation of a photodiode as detector to replace the spectrophotometer. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [41] Development of microfluidic LED sensor platform
    Tae Hyeon Kim
    Jong Min Lee
    Bong Hyun Chung
    Bong Geun Chung
    Nano Convergence, 2
  • [42] Development of an electrochemical sensor for downhole tracer and pH measurements in real-time
    Hess, Ryan
    Klamm, Bonnie
    Goldfarb, Lauren
    Corbin, William
    Boyle, Timothy
    Yelton, William
    Cashion, Avery
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [43] A Robust Sensor for Inline pH Measurements
    Nair, Nikila
    Akshaya, A. V.
    Bosco, Michael John
    Ananthasuresh, G. K.
    Joseph, Jose
    IEEE SENSORS JOURNAL, 2025, 25 (01) : 167 - 174
  • [44] Electronic sensor for pH measurements in nanoliters
    Bouhadda, I.
    De Sagazan, O.
    Le Bihan, F.
    28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 : 915 - 918
  • [45] Optical sensor for interstitial pH measurements
    Baldini, Francesco
    Giannetti, Ambra
    Mencaglia, Andrea A.
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)
  • [46] A Portable 'Plug-and-Play' Fibre Optic Sensor for In-Situ Measurements of pH Values for Microfluidic Applications
    Kumar, Rahul
    Hien Nguyen
    Rente, Bruno
    Tan, Christabel
    Sun, Tong
    Grattan, Kenneth T., V
    MICROMACHINES, 2022, 13 (08)
  • [47] Wireless Sensor Node for Surface Seawater Density Measurements
    Baronti, Federico
    Fantechi, Gabriele
    Roncella, Roberto
    Saletti, Roberto
    SENSORS, 2012, 12 (03) : 2954 - 2968
  • [48] Design and development of a hybrid autonomous system for seawater desalination
    Tzen, E
    Theofilloyianakos, D
    Sigalas, M
    Karamanis, K
    DESALINATION, 2004, 166 (1-3) : 267 - 274
  • [49] Gold Nanoparticle-based Colorimetric Sensor for pH Sensing
    ZHU Lin1
    2. State Key Laboratory of Electroanalytical Chemistry
    Chemical Research in Chinese Universities, 2008, (05) : 537 - 540
  • [50] A fluorescent colorimetric pH sensor and the influences of matrices on sensing performances
    Tian, Yanqing
    Fuller, Emily
    Klug, Summer
    Lee, Fred
    Su, Fengyu
    Zhang, Liqiang
    Chao, Shih-hui
    Meldrum, Deirdre R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 1 - 10