Development of a colorimetric microfluidic pH sensor for autonomous seawater measurements

被引:62
|
作者
Rerolle, Victorie M. C. [1 ]
Floquet, Cedric F. A. [2 ]
Harris, Andy J. K. [2 ]
Mowlem, Matt C. [2 ]
Bellerby, Richard R. G. J. [3 ,4 ,5 ]
Achterberg, Eric P. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
[2] Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
[3] Norwegian Inst Water Res, N-5006 Bergen, Norway
[4] Uni Bjerknes Ctr, Uni Res AS, N-5007 Bergen, Norway
[5] Univ Bergen, Inst Phys, N-5007 Bergen, Norway
基金
英国自然环境研究理事会;
关键词
pH; Colorimetry; Sensor development; Microfluidic pH sensor; LED; Autonomous; M-CRESOL PURPLE; IN-SITU; SPECTROPHOTOMETRIC DETERMINATION; OCEAN-ACIDIFICATION; INORGANIC CARBON; THYMOL BLUE; SEA-WATER; TEMPERATURE; DEPENDENCE; CO2;
D O I
10.1016/j.aca.2013.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High quality carbonate chemistry measurements are required in order to fully understand the dynamics of the oceanic carbonate system. Seawater pH data with good spatial and temporal coverage are particularly critical to apprehend ocean acidification phenomena and their consequences. There is a growing need for autonomous in situ instruments that measure pH on remote platforms. Our aim is to develop an accurate and precise autonomous in situ pH sensor for long term deployment on remote platforms. The widely used spectrophotometric pH technique is capable of the required high-quality measurements. We report a key step towards the miniaturization of a colorimetric pH sensor with the successful implementation of a simple microfluidic design with low reagent consumption. The system is particularly adapted to shipboard deployment: high quality data was obtained over a period of more than a month during a shipboard deployment in northwest European shelf waters, and less than 30 mL of indicator was consumed. The system featured a short term precision of 0.001 pH (n = 20) and an accuracy within the range of a certified Tris buffer (0.004 pH). The quality of the pH system measurements have been checked using various approaches: measurements of certified Tris buffer, measurement of certified seawater for DIC and TA, comparison of measured pH against calculated pH from pCO(2), DIC and TA during the cruise in northwest European shelf waters. All showed that our measurements were of high quality. The measurements were made close to in situ temperature (+0.2 degrees C) in a sampling chamber which had a continuous flow of the ship's underway seawater supply. The optical set up was robust and relatively small due to the use of an USB mini-spectrometer, a custom made polymeric flow cell and an LED light source. The use of a three wavelength LED with detection that integrated power across the whole of each LED output spectrum indicated that low wavelength resolution detectors can be used instead of the current USB mini spectrophotometer. Artefacts due to the polychromatic light source and inhomogeneity in the absorption cell are shown to have a negligible impact on the data quality. The next step in the miniaturization of the sensor will be the incorporation of a photodiode as detector to replace the spectrophotometer. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [21] A high precision spectrophotometric method for on-line shipboard seawater pH measurements: the automated marine pH sensor (AMpS)
    Bellerby, RGJ
    Olsen, A
    Johannessen, T
    Croot, P
    TALANTA, 2002, 56 (01) : 61 - 69
  • [22] Assessment of pH dependent errors in spectrophotometric pH measurements of seawater
    Takeshita, Yuichiro
    Johnson, Kenneth S.
    Coletti, Luke J.
    Jannasch, Hans W.
    Walz, Peter M.
    Warren, Joseph K.
    MARINE CHEMISTRY, 2020, 223 (223)
  • [23] An automated system for spectrophotometric seawater pH measurements
    Carter, B. R.
    Radich, J. A.
    Doyle, H. L.
    Dickson, A. G.
    LIMNOLOGY AND OCEANOGRAPHY-METHODS, 2013, 11 : 16 - 27
  • [24] Development of an 'OFF-ON-OFF' colorimetric and fluorometric pH sensor for the study of physiological pH and its bioimaging application
    Gond, Sarita
    Yadav, Pranjalee
    Chauhan, Brijesh Singh
    Srikrishna, S.
    Singh, Vinod P.
    JOURNAL OF MOLECULAR STRUCTURE, 2022, 1252
  • [25] A design of spectrophotometric microfluidic chip sensor for analyzing silicate in seawater
    Cao, X.
    Zhang, S. W.
    Chu, D. Z.
    Wu, N.
    Ma, H. K.
    Liu, Y.
    3RD INTERNATIONAL CONFERENCE ON WATER RESOURCE AND ENVIRONMENT (WRE 2017), 2017, 82
  • [26] DETERMINATION OF SEAWATER PH FROM 1.5 TO 8.5 USING COLORIMETRIC INDICATORS
    KING, DW
    KESTER, DR
    MARINE CHEMISTRY, 1989, 26 (01) : 5 - 20
  • [27] Colorimetric microfluidic paper-based sensor for determination of nitrite in drinking water with enhanced color development
    Arvand, Mansoor
    Arjmandi, Nima
    Shakibaie, Mehdi
    Jafarinejad, Somayeh
    Shahghadami, Reza
    Sasanpour, Pezhman
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2020, 53 (35)
  • [28] Development of a reference solution for the pH of seawater
    Enrico Prenesti
    Enzo Ferrara
    Silvia Berto
    Paola Fisicaro
    Pier Giuseppe Daniele
    Analytical and Bioanalytical Chemistry, 2007, 388 : 1877 - 1883
  • [29] Development of a reference solution for the pH of seawater
    Prenesti, Enrico
    Ferrara, Enzo
    Berto, Silvia
    Fisicaro, Paola
    Daniele, Pier Giuseppe
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (08) : 1877 - 1883
  • [30] Development of a fibre-optic pH sensor for on-line measurements
    Noui, L
    Javaid, MA
    Keay, PJ
    APPLIED OPTICS AND OPTOELECTRONICS 1998, 1998, : 175 - 180