Development of a colorimetric microfluidic pH sensor for autonomous seawater measurements

被引:62
|
作者
Rerolle, Victorie M. C. [1 ]
Floquet, Cedric F. A. [2 ]
Harris, Andy J. K. [2 ]
Mowlem, Matt C. [2 ]
Bellerby, Richard R. G. J. [3 ,4 ,5 ]
Achterberg, Eric P. [1 ]
机构
[1] Univ Southampton, Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
[2] Natl Oceanog Ctr, Southampton SO14 3ZH, Hants, England
[3] Norwegian Inst Water Res, N-5006 Bergen, Norway
[4] Uni Bjerknes Ctr, Uni Res AS, N-5007 Bergen, Norway
[5] Univ Bergen, Inst Phys, N-5007 Bergen, Norway
基金
英国自然环境研究理事会;
关键词
pH; Colorimetry; Sensor development; Microfluidic pH sensor; LED; Autonomous; M-CRESOL PURPLE; IN-SITU; SPECTROPHOTOMETRIC DETERMINATION; OCEAN-ACIDIFICATION; INORGANIC CARBON; THYMOL BLUE; SEA-WATER; TEMPERATURE; DEPENDENCE; CO2;
D O I
10.1016/j.aca.2013.05.008
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
High quality carbonate chemistry measurements are required in order to fully understand the dynamics of the oceanic carbonate system. Seawater pH data with good spatial and temporal coverage are particularly critical to apprehend ocean acidification phenomena and their consequences. There is a growing need for autonomous in situ instruments that measure pH on remote platforms. Our aim is to develop an accurate and precise autonomous in situ pH sensor for long term deployment on remote platforms. The widely used spectrophotometric pH technique is capable of the required high-quality measurements. We report a key step towards the miniaturization of a colorimetric pH sensor with the successful implementation of a simple microfluidic design with low reagent consumption. The system is particularly adapted to shipboard deployment: high quality data was obtained over a period of more than a month during a shipboard deployment in northwest European shelf waters, and less than 30 mL of indicator was consumed. The system featured a short term precision of 0.001 pH (n = 20) and an accuracy within the range of a certified Tris buffer (0.004 pH). The quality of the pH system measurements have been checked using various approaches: measurements of certified Tris buffer, measurement of certified seawater for DIC and TA, comparison of measured pH against calculated pH from pCO(2), DIC and TA during the cruise in northwest European shelf waters. All showed that our measurements were of high quality. The measurements were made close to in situ temperature (+0.2 degrees C) in a sampling chamber which had a continuous flow of the ship's underway seawater supply. The optical set up was robust and relatively small due to the use of an USB mini-spectrometer, a custom made polymeric flow cell and an LED light source. The use of a three wavelength LED with detection that integrated power across the whole of each LED output spectrum indicated that low wavelength resolution detectors can be used instead of the current USB mini spectrophotometer. Artefacts due to the polychromatic light source and inhomogeneity in the absorption cell are shown to have a negligible impact on the data quality. The next step in the miniaturization of the sensor will be the incorporation of a photodiode as detector to replace the spectrophotometer. Crown Copyright (C) 2013 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:124 / 131
页数:8
相关论文
共 50 条
  • [31] Development of an autonomous centrifugal microfluidic dispenser for POCT
    Okamoto S.
    Ukita Y.
    IEEJ Transactions on Sensors and Micromachines, 2018, 138 (08): : 370 - 375
  • [32] CONTINUOUS SHIPBOARD AND INSITU MEASUREMENTS OF PH AND FLUORESCENCE IN SEAWATER
    MACKEY, DJ
    BUTLER, ECV
    NICHOLS, PD
    HIGGINS, HW
    MARINE CHEMISTRY, 1989, 28 (1-3) : 41 - 60
  • [33] A Microfluidic-Colorimetric Sensor for Continuous Monitoring of Reactive Environmental Chemicals
    Wang, Rui
    Prabhakar, Amlendu
    Iglesias, Rodrigo A.
    Xian, Xiaojun
    Shan, Xiaonan
    Tsow, Francis
    Forzani, Erica S.
    Tao, Nongjian
    IEEE SENSORS JOURNAL, 2012, 12 (05) : 1529 - 1535
  • [34] Rapid Antibiotic Susceptibility Testing in a Microfluidic pH Sensor
    Tang, Yanyan
    Zhen, Li
    Liu, Jingqing
    Wu, Jianmin
    ANALYTICAL CHEMISTRY, 2013, 85 (05) : 2787 - 2794
  • [35] Towards an autonomous microfluidic sensor for dissolved carbon dioxide determination
    de Vargas Sansalvador, Isabel M. Perez
    Lopez Ruiz, Nuria
    Erenas, M. M.
    Capitan Vallvey, Luis Fermin
    Coleman, Simon
    Diamond, Dermot
    Fernandez Ramos, Maria Dolores
    MICROCHEMICAL JOURNAL, 2018, 139 : 216 - 221
  • [36] Seawater pH measurements in the field: A DIY photometer with 0.01 unit pH accuracy
    Yang, Bo
    Patsavas, Mark C.
    Byrne, Robert H.
    Ma, Jian
    MARINE CHEMISTRY, 2014, 160 : 75 - 81
  • [37] Development of microfluidic LED sensor platform
    Kim, Tae Hyeon
    Lee, Jong Min
    Chung, Bong Hyun
    Chung, Bong Geun
    NANO CONVERGENCE, 2015, 2
  • [38] Nano-Sensor Development for Internal pH Measurements Within Marine Organisms
    Aldaleeli, N.
    Dunstan, P.
    OPTICS, PHOTONICS AND LASERS, 2018, : 162 - 163
  • [39] Deployable Lab-on-a-Chip Sensor for Colorimetric Measurements
    Gassmann, Stefan
    Schleifer, Till
    Schuette, Helmut
    MICROMACHINES, 2023, 14 (11)
  • [40] Development of A Microfluidic Based Stretchable Sensor
    Low, Jen-Hahn
    Chee, Pei-Song
    Lim, Eng Hock
    2019 IEEE INTERNATIONAL CONFERENCE ON SENSORS AND NANOTECHNOLOGY (SN), 2019, : 173 - 176