Detection of Breast Cancer with Full-Field Digital Mammography and Computer-Aided Detection

被引:31
|
作者
The, Juliette S. [1 ,2 ]
Schilling, Kathy J. [1 ]
Hoffmeister, Jeffrey W. [3 ]
Friedmann, Euvondia [1 ]
McGinnis, Ryan [1 ]
Holcomb, Richard G. [1 ]
机构
[1] Boca Raton Community Hosp, Ctr Breast Care, Boca Raton, FL 33486 USA
[2] Boca Radiol Grp, Boca Raton, FL USA
[3] iCAD Inc, Beavercreek, OH USA
关键词
breast cancer; computer-aided detection; computer-aided diagnosis; digital images; full-field digital mammography; screening mammography; SCREENING MAMMOGRAPHY; DETECTION SYSTEM; SENSITIVITY; FILM;
D O I
10.2214/AJR.07.3884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate computer-aided detection (CAD) performance with full-field digital mammography (FFDM). MATERIALS AND METHODS. CAD (Second Look, version 7.2) was used to evaluate 123 cases of breast cancer detected with FFDM (Senographe DS). Retrospectively, CAD sensitivity was assessed using breast density, mammographic presentation, histopathology results, and lesion size. To determine the case-based false-positive rate, patients with four standard views per case were included in the study group. Eighteen unilateral mammography examinations with nonstandard views were excluded, resulting in a sample of 105 bilateral cases. RESULTS. CAD detected 115 (94%) of 123 cancer cases: six of six (100%) in fatty breasts, 63 of 66 (95%) in breasts containing scattered fibroglandular densities, 43 of 46 (93%) in heterogeneously dense breasts, and three of five (60%) in extremely dense breasts. CAD detected 93% (41/44) of cancers manifesting as calcifications, 92% (57/62) as masses, and 100% (17/17) as mixed masses and calcifications. CAD detected 94% of the invasive ductal carcinomas (n = 63), 100% of the invasive lobular carcinomas (n = 7), 91% of the other invasive carcinomas (n = 11), and 93% of the ductal carcinomas in situ (n = 42). CAD sensitivity for cancers 1-10 mm (n = 55) was 89%; 11-20 mm (n = 37), 97%; 21-30 mm (n = 16), 100%; and larger than 30 mm (n = 15), 93%. The CAD false-positive rate was 2.3 marks per four-image case. CONCLUSION. CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications and masses. Sensitivity was maintained in cancers with lower mammographic sensitivity, including invasive lobular carcinomas and small neoplasms (1-20 mm). CAD with FFDM should be effective in assisting radiologists with earlier detection of breast cancer. Future studies are needed to assess CAD accuracy in larger populations.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 50 条
  • [1] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Murakami, Ryusuke
    Kumita, Shinichiro
    Tani, Hitomi
    Yoshida, Tamiko
    Sugizaki, Kenichi
    Kuwako, Tomoyuki
    Kiriyama, Tomonari
    Hakozaki, Kenta
    Okazaki, Emi
    Yanagihara, Keiko
    Iida, Shinya
    Haga, Shunsuke
    Tsuchiya, Shinichi
    [J]. JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 768 - 773
  • [2] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Ryusuke Murakami
    Shinichiro Kumita
    Hitomi Tani
    Tamiko Yoshida
    Kenichi Sugizaki
    Tomoyuki Kuwako
    Tomonari Kiriyama
    Kenta Hakozaki
    Emi Okazaki
    Keiko Yanagihara
    Shinya Iida
    Shunsuke Haga
    Shinichi Tsuchiya
    [J]. Journal of Digital Imaging, 2013, 26 : 768 - 773
  • [3] Impact of Breast Density on Computer-Aided Detection in Full-Field Digital Mammography
    Silvia Obenauer
    Christian Sohns
    Carola Werner
    Eckhardt Grabbe
    [J]. Journal of Digital Imaging, 2006, 19
  • [4] Impact of breast density on computer-aided detection in full-field digital mammography
    Obenauer, Silvia
    Sohns, Christian
    Werner, Carola
    Grabbe, Eckhardt
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) : 258 - 263
  • [5] Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers
    Sadaf, Arifa
    Crystal, Pavel
    Scaranelo, Anabel
    Helbich, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (03) : 457 - 461
  • [6] Detection of Breast Cancer in Asymptomatic and Symptomatic Groups Using Computer-Aided Detection with Full-Field Digital Mammography
    Park, Chang Suk
    Jung, Na Young
    Kim, Kijun
    Jung, Hyun Seouk
    Sohn, Kyung-Myung
    Oh, Se Jeong
    [J]. JOURNAL OF BREAST CANCER, 2013, 16 (03) : 322 - 328
  • [7] Computer-Aided Detection with Full-Field Digital Mammography and Screen-Film Mammography
    Melton, A. R.
    Worrell, S. W.
    Knapp, J.
    Hoffmeister, J. W.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [8] Evaluation of breast amorphous calcifications by a computer-aided detection system in full-field digital mammography
    Scaranelo, A. M.
    Eiada, R.
    Bukhanov, K.
    Crystal, P.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 517 - 522
  • [9] Computer-aided detection in direct digital full-field mammography: initial results
    F. Baum
    U. Fischer
    S. Obenauer
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 3015 - 3017
  • [10] Computer-aided detection in direct digital full-field mammography: initial results
    Baum, F
    Fischer, U
    Obenauer, S
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (12) : 3015 - 3017