Detection of Breast Cancer in Asymptomatic and Symptomatic Groups Using Computer-Aided Detection with Full-Field Digital Mammography

被引:5
|
作者
Park, Chang Suk [1 ]
Jung, Na Young [2 ]
Kim, Kijun [1 ]
Jung, Hyun Seouk [1 ]
Sohn, Kyung-Myung [1 ]
Oh, Se Jeong [3 ]
机构
[1] Catholic Univ Korea, Coll Med, Incheon St Marys Hosp, Dept Radiol, Inchon, South Korea
[2] Catholic Univ Korea, Coll Med, Bucheon St Marys Hosp, Dept Radiol, Puchon 420717, South Korea
[3] Catholic Univ Korea, Coll Med, Incheon St Marys Hosp, Dept Surg, Inchon, South Korea
关键词
Breast neoplasms; Computer-assisted diagnosis; Mammography; INVASIVE LOBULAR CARCINOMA; SWEDISH RANDOMIZED TRIALS; SCREENING MAMMOGRAPHY; DETECTION SYSTEM; AMERICAN-COLLEGE; SENSITIVITY; PERFORMANCE; DENSITY;
D O I
10.4048/jbc.2013.16.3.322
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We aimed to determine the sensitivity of computer-aided detection (CAD) applied to digital mammography in asymptomatic and symptomatic breast cancer patients. Methods: We retrospectively analyzed digital mammography and CAD images from 210 patients diagnosed with breast cancer. The patients were divided into symptomatic and asymptomatic groups. The sensitivity of CAD in both groups was assessed in relation to breast tissue density, histopathological type of breast cancer, and tumor size. Results: The detection rate of the CAD system was 87.8% in the asymptomatic group. The sensitivity in different tissue densities was 100% in fatty breasts (P1), 88.9% with scattered fibroglandular densities (P2), 94.4% in heterogeneously dense breasts (P3), and 66.7% in extremely dense breasts (P4). The detection rate of the CAD system in the symptomatic group was 87.2%, and the sensitivity was 90.5%, 90%, 86.6%, and 75% in P1-P4 breasts, respectively. In the asymptomatic group, the CAD system detected 90.3% of invasive ductal carcinomas, not otherwise specified (IDC-NOS) and 88.9% of ductal carcinomas in situ (DCIS), but did not detect other types of malignancy. In the symptomatic group, the CAD system detected 88.2% of IDC-NOS, 88.9% of DCIS and 75% of other types of malignancy. When analyzed according to tumor size, the sensitivity of CAD in the asymptomatic and symptomatic groups was 82.6% and 83.3% for tumors <1 cm, 76.5% and 82.4% for tumors between 1 and 2 cm, and 91.7% and 89% in tumors >2 cm. Conclusion: The sensitivity of CAD was low in P4 breasts and high for tumors larger than 2 cm, with no statistically significant differences between the asymptomatic and symptomatic groups for IDC-NOS and DCIS. CAD showed greater sensitivity for other neoplasms in symptomatic patients.
引用
收藏
页码:322 / 328
页数:7
相关论文
共 50 条
  • [1] Detection of Breast Cancer with Full-Field Digital Mammography and Computer-Aided Detection
    The, Juliette S.
    Schilling, Kathy J.
    Hoffmeister, Jeffrey W.
    Friedmann, Euvondia
    McGinnis, Ryan
    Holcomb, Richard G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) : 337 - 340
  • [2] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Murakami, Ryusuke
    Kumita, Shinichiro
    Tani, Hitomi
    Yoshida, Tamiko
    Sugizaki, Kenichi
    Kuwako, Tomoyuki
    Kiriyama, Tomonari
    Hakozaki, Kenta
    Okazaki, Emi
    Yanagihara, Keiko
    Iida, Shinya
    Haga, Shunsuke
    Tsuchiya, Shinichi
    [J]. JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 768 - 773
  • [3] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Ryusuke Murakami
    Shinichiro Kumita
    Hitomi Tani
    Tamiko Yoshida
    Kenichi Sugizaki
    Tomoyuki Kuwako
    Tomonari Kiriyama
    Kenta Hakozaki
    Emi Okazaki
    Keiko Yanagihara
    Shinya Iida
    Shunsuke Haga
    Shinichi Tsuchiya
    [J]. Journal of Digital Imaging, 2013, 26 : 768 - 773
  • [4] Impact of Breast Density on Computer-Aided Detection in Full-Field Digital Mammography
    Silvia Obenauer
    Christian Sohns
    Carola Werner
    Eckhardt Grabbe
    [J]. Journal of Digital Imaging, 2006, 19
  • [5] Impact of breast density on computer-aided detection in full-field digital mammography
    Obenauer, Silvia
    Sohns, Christian
    Werner, Carola
    Grabbe, Eckhardt
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) : 258 - 263
  • [6] Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers
    Sadaf, Arifa
    Crystal, Pavel
    Scaranelo, Anabel
    Helbich, Thomas
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (03) : 457 - 461
  • [7] Computer-Aided Detection with Full-Field Digital Mammography and Screen-Film Mammography
    Melton, A. R.
    Worrell, S. W.
    Knapp, J.
    Hoffmeister, J. W.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [8] Evaluation of breast amorphous calcifications by a computer-aided detection system in full-field digital mammography
    Scaranelo, A. M.
    Eiada, R.
    Bukhanov, K.
    Crystal, P.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 517 - 522
  • [9] Computer-aided detection in direct digital full-field mammography: initial results
    F. Baum
    U. Fischer
    S. Obenauer
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 3015 - 3017
  • [10] Computer-aided detection in direct digital full-field mammography: initial results
    Baum, F
    Fischer, U
    Obenauer, S
    Grabbe, E
    [J]. EUROPEAN RADIOLOGY, 2002, 12 (12) : 3015 - 3017