Performance of computer-aided detection applied to full-field digital mammography in detection of breast cancers

被引:33
|
作者
Sadaf, Arifa [1 ]
Crystal, Pavel [1 ]
Scaranelo, Anabel [2 ]
Helbich, Thomas [3 ]
机构
[1] Mt Sinai Hosp, Dept Med Imaging, Toronto, ON M5G 1X5, Canada
[2] Princess Margaret Hosp, Dept Med Imaging, Toronto, ON M5G 2M9, Canada
[3] Med Univ Vienna, Gen Hosp Vienna, A-1090 Vienna, Austria
关键词
Mammography; Computer-assisted detection; Breast cancer; SCREENING MAMMOGRAPHY; DETECTION SYSTEM; FILM MAMMOGRAPHY; DETECTION CAD; SENSITIVITY; APPEARANCE; PROGRAM; IMPACT;
D O I
10.1016/j.ejrad.2009.08.024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The aim of this retrospective study was to evaluate performance of computer-aided detection (CAD) with full-field digital mammography (FFDM) in detection of breast cancers. Materials and Methods: CAD was retrospectively applied to standard mammographic views of 127 cases with biopsy proven breast cancers detected with FFDM (Senographe 2000, GE Medical Systems). CAD sensitivity was assessed in total group of 127 cases and for subgroups based on breast density, mammographic lesion type, mammographic lesion size, histopathology and mode of presentation. Results: Overall CAD sensitivity was 91% (115 of 127 cases). There were no statistical differences (p > 0.1) in CAD detection of cancers in dense breasts 90% (53/59) versus non-dense breasts 91% (62/68). There was statistical difference (p < 0.05) in CAD detection of cancers that appeared mammographically as micro-calcifications only versus other mammographic manifestations. CAD detected 100% (44/44) of cancers manifesting as microcalcifications, 89% (47/53) as no-calcified masses or asymmetries, 88% (14/16) as masses with associated calcifications, and 71% (10/14) as architectural distortions. CAD sensitivity for cancers 1-10 mm was 84% (38/45); 11-20 mm 93% (55/59); and > 20 mm 97% (22/23). Conclusion: CAD applied to FFDM showed 100% sensitivity in identifying cancers manifesting as microcalcifications only and high sensitivity 86% (71/83) for other mammographic appearances of cancer. Sensitivity is influenced by lesion size. CAD in FFDM is an adjunct helping radiologist in early detection of breast cancers. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:457 / 461
页数:5
相关论文
共 50 条
  • [1] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Murakami, Ryusuke
    Kumita, Shinichiro
    Tani, Hitomi
    Yoshida, Tamiko
    Sugizaki, Kenichi
    Kuwako, Tomoyuki
    Kiriyama, Tomonari
    Hakozaki, Kenta
    Okazaki, Emi
    Yanagihara, Keiko
    Iida, Shinya
    Haga, Shunsuke
    Tsuchiya, Shinichi
    [J]. JOURNAL OF DIGITAL IMAGING, 2013, 26 (04) : 768 - 773
  • [2] Detection of Breast Cancer with a Computer-Aided Detection Applied to Full-Field Digital Mammography
    Ryusuke Murakami
    Shinichiro Kumita
    Hitomi Tani
    Tamiko Yoshida
    Kenichi Sugizaki
    Tomoyuki Kuwako
    Tomonari Kiriyama
    Kenta Hakozaki
    Emi Okazaki
    Keiko Yanagihara
    Shinya Iida
    Shunsuke Haga
    Shinichi Tsuchiya
    [J]. Journal of Digital Imaging, 2013, 26 : 768 - 773
  • [3] Detection of Breast Cancer with Full-Field Digital Mammography and Computer-Aided Detection
    The, Juliette S.
    Schilling, Kathy J.
    Hoffmeister, Jeffrey W.
    Friedmann, Euvondia
    McGinnis, Ryan
    Holcomb, Richard G.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) : 337 - 340
  • [4] Impact of Breast Density on Computer-Aided Detection in Full-Field Digital Mammography
    Silvia Obenauer
    Christian Sohns
    Carola Werner
    Eckhardt Grabbe
    [J]. Journal of Digital Imaging, 2006, 19
  • [5] Impact of breast density on computer-aided detection in full-field digital mammography
    Obenauer, Silvia
    Sohns, Christian
    Werner, Carola
    Grabbe, Eckhardt
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) : 258 - 263
  • [6] Screening mammography detected cancers: Sensitivity of a computer-aided detection system applied to full-field digital mammograms
    Yang, Sang Kyu
    Moon, Woo Kyung
    Cho, Nariya
    Park, Jeong Seon
    Cha, Joo Hee
    Kim, Sun Mi
    Kim, Seung Ja
    Im, Jung-Gi
    [J]. RADIOLOGY, 2007, 244 (01) : 104 - 111
  • [7] Computer-Aided Detection with Full-Field Digital Mammography and Screen-Film Mammography
    Melton, A. R.
    Worrell, S. W.
    Knapp, J.
    Hoffmeister, J. W.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [8] Evaluation of breast amorphous calcifications by a computer-aided detection system in full-field digital mammography
    Scaranelo, A. M.
    Eiada, R.
    Bukhanov, K.
    Crystal, P.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013): : 517 - 522
  • [9] Computer-aided detection system applied to full-field digital mammograms
    Vega Bolivar, Alfonso
    Sanchez Gomez, Sonia
    Merino, Paula
    Alonso-Bartolome, Pilar
    Ortega Garcia, Estrella
    Munoz Cacho, Pedro
    Hoffmeister, Jeffrey W.
    [J]. ACTA RADIOLOGICA, 2010, 51 (10) : 1086 - 1092
  • [10] Computer-aided detection in direct digital full-field mammography: initial results
    F. Baum
    U. Fischer
    S. Obenauer
    E. Grabbe
    [J]. European Radiology, 2002, 12 : 3015 - 3017