Detection of Breast Cancer with Full-Field Digital Mammography and Computer-Aided Detection

被引:31
|
作者
The, Juliette S. [1 ,2 ]
Schilling, Kathy J. [1 ]
Hoffmeister, Jeffrey W. [3 ]
Friedmann, Euvondia [1 ]
McGinnis, Ryan [1 ]
Holcomb, Richard G. [1 ]
机构
[1] Boca Raton Community Hosp, Ctr Breast Care, Boca Raton, FL 33486 USA
[2] Boca Radiol Grp, Boca Raton, FL USA
[3] iCAD Inc, Beavercreek, OH USA
关键词
breast cancer; computer-aided detection; computer-aided diagnosis; digital images; full-field digital mammography; screening mammography; SCREENING MAMMOGRAPHY; DETECTION SYSTEM; SENSITIVITY; FILM;
D O I
10.2214/AJR.07.3884
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to evaluate computer-aided detection (CAD) performance with full-field digital mammography (FFDM). MATERIALS AND METHODS. CAD (Second Look, version 7.2) was used to evaluate 123 cases of breast cancer detected with FFDM (Senographe DS). Retrospectively, CAD sensitivity was assessed using breast density, mammographic presentation, histopathology results, and lesion size. To determine the case-based false-positive rate, patients with four standard views per case were included in the study group. Eighteen unilateral mammography examinations with nonstandard views were excluded, resulting in a sample of 105 bilateral cases. RESULTS. CAD detected 115 (94%) of 123 cancer cases: six of six (100%) in fatty breasts, 63 of 66 (95%) in breasts containing scattered fibroglandular densities, 43 of 46 (93%) in heterogeneously dense breasts, and three of five (60%) in extremely dense breasts. CAD detected 93% (41/44) of cancers manifesting as calcifications, 92% (57/62) as masses, and 100% (17/17) as mixed masses and calcifications. CAD detected 94% of the invasive ductal carcinomas (n = 63), 100% of the invasive lobular carcinomas (n = 7), 91% of the other invasive carcinomas (n = 11), and 93% of the ductal carcinomas in situ (n = 42). CAD sensitivity for cancers 1-10 mm (n = 55) was 89%; 11-20 mm (n = 37), 97%; 21-30 mm (n = 16), 100%; and larger than 30 mm (n = 15), 93%. The CAD false-positive rate was 2.3 marks per four-image case. CONCLUSION. CAD with FFDM showed a high sensitivity in identifying cancers manifesting as calcifications and masses. Sensitivity was maintained in cancers with lower mammographic sensitivity, including invasive lobular carcinomas and small neoplasms (1-20 mm). CAD with FFDM should be effective in assisting radiologists with earlier detection of breast cancer. Future studies are needed to assess CAD accuracy in larger populations.
引用
收藏
页码:337 / 340
页数:4
相关论文
共 50 条
  • [31] Who could benefit the most from using a computer-aided detection system in full-field digital mammography?
    Na Young Jung
    Bong Joo Kang
    Hyeon Sook Kim
    Eun Suk Cha
    Jae Hee Lee
    Chang Suk Park
    In Young Whang
    Sung Hun Kim
    Yeong Yi An
    Jae Jeong Choi
    [J]. World Journal of Surgical Oncology, 12
  • [32] Who could benefit the most from using a computer-aided detection system in full-field digital mammography?
    Jung, Na Young
    Kang, Bong Joo
    Kim, Hyeon Sook
    Cha, Eun Suk
    Lee, Jae Hee
    Park, Chang Suk
    Whang, In Young
    Kim, Sung Hun
    An, Yeong Yi
    Choi, Jae Jeong
    [J]. WORLD JOURNAL OF SURGICAL ONCOLOGY, 2014, 12
  • [33] Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training
    Kallenberg, Michiel
    Karssemeijer, Nico
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23): : 6879 - 6891
  • [34] Computer-aided detection of breast masses on full field digital mammogranris
    Wei, J
    Sahiner, B
    Hadjiiski, LM
    Chan, HP
    Petrick, N
    Helvie, MA
    Roubidoux, MA
    Ge, J
    Zhou, C
    [J]. MEDICAL PHYSICS, 2005, 32 (09) : 2827 - 2838
  • [35] Breast Cancer Detection in a Screening Population: Comparison of Digital Mammography, Computer-Aided Detection Applied to Digital Mammography and Breast Ultrasound
    Cho, Kyu Ran
    Seo, Bo Kyoung
    Woo, Ok Hee
    Song, Sung Eun
    Choi, Jungsoon
    Whang, Shin Young
    Park, Eun Kyung
    Park, Ah Young
    Shin, Hyeseon
    Chung, Hwan Hoon
    [J]. JOURNAL OF BREAST CANCER, 2016, 19 (03) : 316 - 323
  • [36] Computer-aided diagnosis (CAD) of images obtained on full-field digital mammography
    Nishikawa, RM
    Giger, ML
    Yarusso, LM
    Kupinski, MA
    Baehr, AE
    Venta, LA
    [J]. RADIOLOGY, 1999, 213P : 229 - 229
  • [37] Computer-aided breast cancer detection in screening mammography
    Bick, U
    Giger, ML
    Schmidt, RA
    Nishikawa, RM
    Wolverton, DE
    Doi, K
    [J]. DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 97 - 103
  • [38] Computer-Aided Detection and Diagnosis of Breast Abnormalities in Digital Mammography
    Bozek, Jelena
    Delac, Kresimir
    Grgic, Mislav
    [J]. PROCEEDINGS ELMAR-2008, VOLS 1 AND 2, 2008, : 45 - 52
  • [39] Microcalcification detection in full-field digital mammograms: A fully automated computer-aided system
    Basile, T. M. A.
    Fanizzi, A.
    Losurdo, L.
    Bellotti, R.
    Bottigli, U.
    Dentamaro, R.
    Didonna, V
    Fausto, A.
    Massafra, R.
    Moschetta, M.
    Tamborra, P.
    Tangaro, S.
    La Forgia, D.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 1 - 9
  • [40] Accuracy of breast cancer detection with full-field digital mammography (FFDM) and integral computer-aided detection (CAD) correlated with breast density as assessed by a new automated volumetric breast density measurement system
    Pinker, K.
    Milner, S.
    Stephen, D.
    Mokbel, K.
    Perry, N. M.
    [J]. EJC SUPPLEMENTS, 2010, 8 (03): : 232 - 232