A simple flow cytometric assay for routine paroxysmal nocturnal hemoglobinuria testing based on immature reticulocytes and granulocytes

被引:7
|
作者
Tsagarakis, Nikolaos J. [1 ]
Paterakis, George [1 ]
机构
[1] Athens Reg Gen Hosp G Gennimatas, Dept Immunol, Flow Cytometry Lab, Athens 11527, Greece
关键词
PNH; flow cytometry; CD71; reticulocytes; PNH granulocytes; PNH diagnosis; CD59; EXPRESSION; DIAGNOSIS;
D O I
10.1002/cyto.b.21030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The aim of this study was to test an easy-to-perform flow cytometric (FCM) assay for the routine investigation for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH), through the simultaneous detection of PNH clones on immature reticulocytes (i-RET) and granulocytes. Methods: During the last 5 years, eight patients were diagnosed with PNH in our laboratory, among 90 patients prospectively studied for PNH. The determination of glycosylphosphatidylinositol (GPI) deficient cells on the erythroid lineage was made with a two-color FCM assay of CD71 and CD59, evaluating the PNH clone on i-RET. Three color combinations based on CD66b/CD16/CD45 and CD59/CD24/CD45 were used for the determination of GPI-deficient granulocytes. Results: In all the patients with PNH, the PNH clones determined with CD71(+)CD59(-) red blood cells (RBC) were nearly identical to the respective clones determined with CD16(dim/-)/CD66b(-) and CD59(-)/CD24(-) granulocytes, in contrast to the clones determined with CD59-deficient erythrocytes only, which were significantly lower. Conclusions: Our results indicate that the simultaneous assessment of the PNH clone on CD71(+)/CD59(-)i-RET and CD16(dim/-)/CD66b(-) granulocytes, could offer a reliable method of two series PNH screening, at low cost and with ease of application. (c) 2012 International Clinical Cytometry Society
引用
收藏
页码:259 / 263
页数:5
相关论文
共 50 条
  • [41] High-Sensitivity Flow Cytometry Testing for Paroxysmal Nocturnal Hemoglobinuria in Children with Cytopenia: A Single Center Study
    Curry, Choladda V.
    Elghetany, M. Tarek
    Sheehan, Andrea M.
    Bertuch, Alison A.
    Sasa, Ghadir S.
    BLOOD, 2011, 118 (21) : 1031 - 1032
  • [42] High-Sensitivity Flow Cytometry Testing for Paroxysmal Nocturnal Hemoglobinuria in Children with Cytopenia: A Single Center Study
    Donohue, R. E.
    Redkar, A. A.
    Sasa, G. S.
    Elghetany, T. M.
    Sheehan, A. M.
    Bertuch, A. A.
    Curry, C. V.
    MODERN PATHOLOGY, 2014, 27 : 345A - 346A
  • [43] High-Sensitivity Flow Cytometry Testing for Paroxysmal Nocturnal Hemoglobinuria in Children with Cytopenia: A Single Center Study
    Donohue, R. E.
    Redkar, A. A.
    Sasa, G. S.
    Elghtany, T. M.
    Sheehan, A. M.
    Bertuch, A. A.
    Curry, C. V.
    LABORATORY INVESTIGATION, 2014, 94 : 345A - 346A
  • [44] Acclerated telomere shortening in GPI(-) granulocytes from patients with paroxysmal nocturnal hemoglobinuria (PNH) detected by newly developed Proaerolysin flow-fish
    Beier, F
    Balabanov, S
    Buckley, T
    Dietz, K
    Hartmann, U
    Rojewski, M
    Kanz, L
    Schrezenmeier, H
    Brümmendorf, TH
    EXPERIMENTAL HEMATOLOGY, 2005, 33 (07) : 103 - 103
  • [45] Sensitive Detection of Survival of Paroxysmal Nocturnal Hemoglobinuria (PNH) Clones in Red Blood Cells, Granulocytes and Monocytes by High Resoluion Multiparameter Flow Cytometry
    Movalia, Mayur K.
    Illingworth, Andrea
    BLOOD, 2008, 112 (11) : 1178 - 1179
  • [46] FLOW CYTOMETRIC DIAGNOSIS OF PAROXYSMAL-NOCTURNAL HEMOGLOBINURIA BY MONOCLONAL-ANTIBODIES WITH SPECIFICITY FOR GLYCOSYL-PHOSPHATIDYLINOSITOL-ANCHORED MEMBRANE-PROTEINS
    LOHMEYER, J
    HADAM, M
    PRALLE, H
    MEDIZINISCHE WELT, 1993, 44 (03): : 191 - 195
  • [47] Establishment of a flow cytometry assay for detecting paroxysmal nocturnal hemoglobinuria-type cells specific to patients with bone marrow failure
    Kohei Hosokawa
    Chiharu Sugimori
    Ken Ishiyama
    Hiroyuki Takamatsu
    Hideyoshi Noji
    Tsutomu Shichishima
    Naoshi Obara
    Shigeru Chiba
    Haruhiko Ninomiya
    Yukari Shirasugi
    Yoshihiko Nakamura
    Kiyoshi Ando
    Yasutaka Ueda
    Yuji Yonemura
    Tatsuya Kawaguchi
    Jun-ichi Nishimura
    Yuzuru Kanakura
    Shinji Nakao
    Annals of Hematology, 2018, 97 : 2289 - 2297
  • [48] Comparison of a dual color flow cytometry (FC) assay and the RedQuant/CellQuant kit for detection of paroxysmal nocturnal hemoglobinuria (PNH) cells
    Stahl, S
    Maciejewski, JP
    Hsi, ED
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2005, 68B (01) : 66 - 67
  • [49] Establishment of a flow cytometry assay for detecting paroxysmal nocturnal hemoglobinuria-type cells specific to patients with bone marrow failure
    Hosokawa, Kohei
    Sugimori, Chiharu
    Ishiyama, Ken
    Takamatsu, Hiroyuki
    Noji, Hideyoshi
    Shichishima, Tsutomu
    Obara, Naoshi
    Chiba, Shigeru
    Ninomiya, Haruhiko
    Shirasugi, Yukari
    Nakamura, Yoshihiko
    Ando, Kiyoshi
    Ueda, Yasutaka
    Yonemura, Yuji
    Kawaguchi, Tatsuya
    Nishimura, Jun-ichi
    Kanakura, Yuzuru
    Nakao, Shinji
    ANNALS OF HEMATOLOGY, 2018, 97 (12) : 2289 - 2297
  • [50] Flow cytometric analysis of erythrocytes in paroxysmal nocturnal hemoglobinuria reveals superiority of CD59 as a diagnostic marker compared to CD55
    Tembhare, Prashant
    Ramani, Manisha
    Syed, Keerti
    Das Gupta, Amar
    INDIAN JOURNAL OF PATHOLOGY AND MICROBIOLOGY, 2010, 53 (04) : 699 - 703