A simple flow cytometric assay for routine paroxysmal nocturnal hemoglobinuria testing based on immature reticulocytes and granulocytes

被引:7
|
作者
Tsagarakis, Nikolaos J. [1 ]
Paterakis, George [1 ]
机构
[1] Athens Reg Gen Hosp G Gennimatas, Dept Immunol, Flow Cytometry Lab, Athens 11527, Greece
关键词
PNH; flow cytometry; CD71; reticulocytes; PNH granulocytes; PNH diagnosis; CD59; EXPRESSION; DIAGNOSIS;
D O I
10.1002/cyto.b.21030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The aim of this study was to test an easy-to-perform flow cytometric (FCM) assay for the routine investigation for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH), through the simultaneous detection of PNH clones on immature reticulocytes (i-RET) and granulocytes. Methods: During the last 5 years, eight patients were diagnosed with PNH in our laboratory, among 90 patients prospectively studied for PNH. The determination of glycosylphosphatidylinositol (GPI) deficient cells on the erythroid lineage was made with a two-color FCM assay of CD71 and CD59, evaluating the PNH clone on i-RET. Three color combinations based on CD66b/CD16/CD45 and CD59/CD24/CD45 were used for the determination of GPI-deficient granulocytes. Results: In all the patients with PNH, the PNH clones determined with CD71(+)CD59(-) red blood cells (RBC) were nearly identical to the respective clones determined with CD16(dim/-)/CD66b(-) and CD59(-)/CD24(-) granulocytes, in contrast to the clones determined with CD59-deficient erythrocytes only, which were significantly lower. Conclusions: Our results indicate that the simultaneous assessment of the PNH clone on CD71(+)/CD59(-)i-RET and CD16(dim/-)/CD66b(-) granulocytes, could offer a reliable method of two series PNH screening, at low cost and with ease of application. (c) 2012 International Clinical Cytometry Society
引用
收藏
页码:259 / 263
页数:5
相关论文
共 50 条
  • [31] Flow cytometric analysis of glycosylphosphatidyl-inositol-anchored proteins to assess paroxysmal nocturnal hemoglobinuria clone size
    Piedras, J
    López-Karpovitch, X
    CYTOMETRY, 2000, 42 (04): : 234 - 238
  • [32] CD16-56/SSC plot in routine flow: A resource for screening of paroxysmal nocturnal Hemoglobinuria?
    Davanzo, V.
    Fogar, P.
    Zuin, J.
    Falda, A.
    Centa, P.
    Basso, D.
    CLINICA CHIMICA ACTA, 2024, 558
  • [33] A standardized flow cytometric approach for screening patients suspected for paroxysmal nocturnal hemoglobinuria (PNH) measuring CD55 and CD59 expression in erythrocytes and granulocytes.
    Oelschlaegel, U
    Besson, I
    Nowak, R
    Bux, Y
    Naumann, R
    Berndt, A
    Ehninger, G
    BLOOD, 2000, 96 (11) : 13B - 13B
  • [34] A highly sensitive flow cytometry assay for the detection of paroxysmal nocturnal hemoglobinuria cells in patients with myelodysplastic syndrome
    Pozdnyakova, Olga
    Woda, Bruce A.
    Stachurski, Dariusz
    Xiao, Zhefu F.
    Raza, Azra
    Wang, Sa A.
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2006, 70B (05) : 373 - 374
  • [35] Isolated CD59 deficiency mimicking paroxysmal nocturnal hemoglobinuria (PNH) - flow cytometric detection and genetic characterization
    Hoechsmann, B.
    Dohna-Schwake, C.
    Rojewski, M.
    Schwarz, K.
    Pannicke, U.
    Schara, U.
    Wieland, R.
    Schrezenmeier, H.
    ONKOLOGIE, 2010, 33 : 112 - 113
  • [36] Technical advances in flow cytometry-based diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria
    Correia, Rodolfo Patussi
    Bento, Laiz Cameirao
    Apelle Bortolucci, Ana Carolina
    Alexandre, Anderson Marega
    Vaz, Andressa da Costa
    Schimidell, Daniela
    Pedro, Eduardo de Carvalho
    Perin, Fabricio Simoes
    Nozawa, Sonia Tsukasa
    Albers Mendes, Claudio Ernesto
    Barroso, Rodrigo de Souza
    Bacal, Nydia Strachman
    EINSTEIN-SAO PAULO, 2016, 14 (03): : 366 - 373
  • [37] A novel flow cytometric based extended differential method for the measurement of circulating immature granulocytes
    Lopez, Lidice
    Careaga, Diana
    Rubio, Oilda
    Paul, Ronald
    Mylvaganam, Ravindra
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 : 56 - 56
  • [38] CD16-56/SSC PLOT IN ROUTINE FLOW CYTOMETRY: A RESOURCE FOR SCREENING OF PAROXYSMAL NOCTURNAL HEMOGLOBINURIA?
    Davanzo, Veronica
    Fogar, Paola
    Falda, Alessandra
    Zuin, Jenny
    Centa, Paola
    Basso, Daniela
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2024, 46 : 28 - 29
  • [39] High sensitivity 8-color flow cytometry assay for paroxysmal nocturnal hemoglobinuria granulocyte and monocyte detections
    Chan, Ray Chun-Fai
    Leung, Richard H.
    Posadas, Albert
    Lorey, Thomas S.
    Shaw, Allison J.
    BIOMEDICAL REPORTS, 2018, 8 (03) : 224 - 234
  • [40] VARIABILITY OF FLOW CYTOMETRY SCREENING FOR PAROXYSMAL NOCTURNAL HEMOGLOBINURIA IN FIVE COMMUNITY BASED ONCOLOGY PRACTICES
    Forsyth, Michael T.
    Shankleton, Jeff A.
    Cardona-Pelaez, Jorge N.
    Khursigara, Gus
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (06) : 399 - 399