A simple flow cytometric assay for routine paroxysmal nocturnal hemoglobinuria testing based on immature reticulocytes and granulocytes

被引:7
|
作者
Tsagarakis, Nikolaos J. [1 ]
Paterakis, George [1 ]
机构
[1] Athens Reg Gen Hosp G Gennimatas, Dept Immunol, Flow Cytometry Lab, Athens 11527, Greece
关键词
PNH; flow cytometry; CD71; reticulocytes; PNH granulocytes; PNH diagnosis; CD59; EXPRESSION; DIAGNOSIS;
D O I
10.1002/cyto.b.21030
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The aim of this study was to test an easy-to-perform flow cytometric (FCM) assay for the routine investigation for diagnosis of paroxysmal nocturnal hemoglobinuria (PNH), through the simultaneous detection of PNH clones on immature reticulocytes (i-RET) and granulocytes. Methods: During the last 5 years, eight patients were diagnosed with PNH in our laboratory, among 90 patients prospectively studied for PNH. The determination of glycosylphosphatidylinositol (GPI) deficient cells on the erythroid lineage was made with a two-color FCM assay of CD71 and CD59, evaluating the PNH clone on i-RET. Three color combinations based on CD66b/CD16/CD45 and CD59/CD24/CD45 were used for the determination of GPI-deficient granulocytes. Results: In all the patients with PNH, the PNH clones determined with CD71(+)CD59(-) red blood cells (RBC) were nearly identical to the respective clones determined with CD16(dim/-)/CD66b(-) and CD59(-)/CD24(-) granulocytes, in contrast to the clones determined with CD59-deficient erythrocytes only, which were significantly lower. Conclusions: Our results indicate that the simultaneous assessment of the PNH clone on CD71(+)/CD59(-)i-RET and CD16(dim/-)/CD66b(-) granulocytes, could offer a reliable method of two series PNH screening, at low cost and with ease of application. (c) 2012 International Clinical Cytometry Society
引用
收藏
页码:259 / 263
页数:5
相关论文
共 50 条
  • [11] A NOVEL DUAL-REAGENT SINGLE TUBE FLOW CYTOMETRIC ASSAY TO SCREEN PAROXYSMAL NOCTURNAL HEMOGLOBINURIA
    Bommannan, K.
    Sachdeva, M. U. S.
    Ahluwalia, J.
    Bose, P.
    Varma, N.
    HAEMATOLOGICA, 2017, 102 : 405 - 406
  • [12] Enhanced expression of CD71, transferrin receptor, on immature reticulocytes in patients with paroxysmal nocturnal hemoglobinuria
    Sato, S.
    Kozuma, Y.
    Hasegawa, Y.
    Kojima, H.
    Chiba, S.
    Ninomiya, H.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2010, 32 (01) : E137 - E143
  • [13] MEDICAL INDICATIONS FOR PAROXYSMAL NOCTURNAL HEMOGLOBINURIA TESTING BY FLOW CYTOMETRY
    Perez-Andres, Martin
    Subira, Dolores
    Sempere, Amparo
    Serrano, Cristina
    Colado, Enrique
    Morado, Marta
    Angel Diaz, Jose
    Alvarez, Beatriz
    Noya, Mercedes
    Isusi, Paloma
    Fernandez, Carlos
    Etxaniz, Pilar
    Minguela, Alfredo
    Lemes, Angelina
    Cristina Fernandez, M.
    Orfao, Alberto
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2011, 80B (06) : 414 - 414
  • [14] FLOW CYTOMETRIC ASSAY FOR DETECTION OF PNH CELL POPULATIONS IN PAROXYSMAL NOCTURNAL HEMOGLOBINURIA AND OTHER BONE MARROW FAILURE DISEASES
    Lugovskaya, Svetlana
    Naumova, Elena
    Pochtar, Margarita
    Kisilichina, Darya
    Plekhanova, Olga
    Tsvetaeva, Nina
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 : 54 - 54
  • [15] FLOW CYTOMETRIC ANALYSIS IN PAROXYSMAL NOCTURNAL HEMOGLOBINURIA (HPN): A SCREENING OF 161 ALGERIAN PATIENTS
    Harieche, F.
    Boukhemia, F.
    Abdennebi, N.
    Talbi, A.
    Mehdid, F.
    Rahmoune, N.
    Aouanouk, N.
    Zerhouni, F.
    Hamladji, R. M.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2010, 95 : 671 - 672
  • [16] Clinical course and flow cytometric analysis of paroxysmal nocturnal hemoglobinuria in the United States and Japan
    Nishimura, JI
    Kanakura, Y
    Ware, RE
    Shichishima, T
    Nakakuma, H
    Ninomiya, H
    Decastro, CM
    Hall, S
    Kanamaru, A
    Sullivan, KM
    Mizoguchi, H
    Omine, M
    Kinoshita, T
    Rosse, WF
    MEDICINE, 2004, 83 (03) : 193 - 207
  • [17] Integration of chromosomal damage assessment with routine toxicity testing using a flow cytometric assay for micronucleated reticulocytes.
    MacGregor, J
    Bishop, ME
    Dertinger, S
    McNamee, J
    Harper, S
    Hotchkiss, C
    Hayashi, M
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2004, 44 (03) : 213 - 213
  • [18] Immunophenotypic Abnormalities Highly Suggestive of Paroxysmal Nocturnal Hemoglobinuria (PNH) Can Be Detected with Routine Flow Cytometric Analysis of Bone Marrow (BM)
    Florea, Alina Dulau
    Young, Neal S.
    Maric, Irina
    Jordan, Elaine K.
    Jiang, Chunjie
    Ahmad, Farhan
    Braylan, Raul
    LABORATORY INVESTIGATION, 2017, 97 : 346A - 346A
  • [19] Immunophenotypic Abnormalities Highly Suggestive of Paroxysmal Nocturnal Hemoglobinuria (PNH) Can Be Detected with Routine Flow Cytometric Analysis of Bone Marrow (BM)
    Florea, Alina Dulau
    Young, Neal S.
    Maric, Irina
    Jordan, Elaine K.
    Jiang, Chunjie
    Ahmad, Farhan
    Braylan, Raul
    MODERN PATHOLOGY, 2017, 30 : 346A - 346A
  • [20] Diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH) with a new 6-color flow cytometric approach
    Oelschlaegel, U.
    Klotsche, C.
    Ehninger, G.
    Thiede, C.
    ONKOLOGIE, 2010, 33 : 50 - 50