Undersensing of ventricular fibrillation in a noncommitted nonthoracotomy cardioverter defibrillator system

被引:6
|
作者
Peralta, AO [1 ]
John, RM [1 ]
Venditti, FJ [1 ]
Martin, DT [1 ]
机构
[1] LAHEY CLIN MED CTR,CARDIAC ELECTROPHYSIOL LAB,BURLINGTON,MA 01805
来源
关键词
undersensing; defibrillation; implantable cardioverter defibrillators;
D O I
10.1111/j.1540-8159.1997.tb03878.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Evaluation of the impact of undersensing on VF detection time and the relationship of undersensing to the programmed shock energy. Background: Failure to reconfirm on ongoing arrhythmia due to undersensing by a noncommitted ICD might prolong the time to therapy. Methods: We measured initial detection times and redetection times at predischarge and at 2 and 6 months in 29 patients (22 men, mean age 60 years) with a noncommitted nonthoracotomy ICD. Telemetry data and output markers were used to analyze each induction. Results: Undersensing leading io failure to reconfirm was present in 44 (11.1%) of 398 episodes of sustained VF and prolonged significantly the median initial detection time from 2.3 seconds (25th and 75th percentiles: 2 and 2.6 s, respectively) to 5.45 seconds (4.3 and 7.35 s, P < 0.0001). One episode required external defibrillation after reconfirmation failure occurred during charging; the total detection time prior to shock was 46 seconds. In a subset of 87 episodes with failed first shocks, the initial detection time was 2.3 seconds (2.1 and 2.8 s) and the redetection time 3 seconds (2.5 and 4.7 s, P < 0.0001). The presence of undersensing prolonged the redetection from 2.6 seconds (2.35 and 3.1 s) to 5.4 seconds (4.53 and 7.35 s, P < 0.0001). Undersensing was more prevalent during the redetection period (P = 0.004) and in episodes of sustained VF in which the first shock energy was higher than 15 J (19.7% vs 5.8%, P < 0.0001). Conclusions: In this automatic defibrillator system, undersensing occurs in 11% of the sustained VF inductions and prolongs detection time significantly. Redetection is longer than initial detection mostly due to the presence of undersensing, the frequency of which is proportional to the programmed energy. The clinical significance of this finding is unknown.
引用
收藏
页码:610 / 618
页数:9
相关论文
共 50 条
  • [31] APPROPRIATE SENSING OF VENTRICULAR-FIBRILLATION AFTER FAILED SHOCKS IN A TRANSVENOUS CARDIOVERTER-DEFIBRILLATOR SYSTEM
    ELLIS, JR
    MARTIN, DT
    VENDITTI, FJ
    CIRCULATION, 1994, 90 (04) : 1820 - 1825
  • [32] Inappropriate detection and therapy from an implantable cardioverter defibrillator due to atrial undersensing
    Paraskevaidis, S
    Polymeropoulos, K
    Vassilikos, V
    Louridas, G
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09): : 1002 - 1004
  • [33] Failure to detect ventricular fibrillation in a patient with an implantable cardioverter-defibrillator [3]
    Antolinos-Pérez, María J.
    García-Alberola, Arcadio
    Redondo-Bermejo, Belén
    Valdés-Chávarri, Mariano
    Technische Uberwachung, 2006, 47 (06): : 517 - 518
  • [34] The implantable cardioverter defibrillator prolongs survival in ventricular fibrillation patients who are revascularized
    Link, MS
    Cesarz, CA
    Costeas, XF
    Estes, NAM
    Wang, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 37126 - 37126
  • [35] Efficacy and limitations of treatment of ventricular fibrillation/ventricular tachycardia storm by subcutaneous implantable cardioverter defibrillator
    Nagra, Bipinpreet
    Awan, Muhammad Umer
    Miriyala, Varun
    Kantharia, Bharat K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2016, 222 : 978 - 979
  • [36] Cardiac events in patients with idiopathic ventricular fibrillation after a cardioverter defibrillator implantation
    Champagne, JJC
    Portegies, MMP
    Roba, MMR
    Anguera, IIA
    Brugada, PPB
    CIRCULATION, 1999, 100 (18) : 571 - 571
  • [37] SHOCK DELIVERED BY AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN RESPONSE TO SPONTANEOUS VENTRICULAR FIBRILLATION
    ROELKE, M
    ONUNAIN, SS
    NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (13): : 860 - 860
  • [38] Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation
    Taneja, T
    Goldberger, J
    Parker, MA
    Johnson, D
    Robinson, N
    Horvath, G
    Kadish, AH
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (11) : 1209 - 1217
  • [39] Underdetection of Ventricular Fibrillation by Wearable Cardioverter-Defibrillator Leading to Sudden Death
    Kokubun, Hiroto
    Miyauchi, Yasushi
    Inada, Shin
    Shimizu, Wataru
    CIRCULATION JOURNAL, 2021, 85 (01) : 79 - 79
  • [40] Asymptomatic superior vena caval occlusion: A complication of nonthoracotomy implantation of cardioverter defibrillator
    Minen, G
    Proclemer, A
    Facchin, D
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (08): : 1676 - 1678