Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation

被引:17
|
作者
Taneja, T
Goldberger, J
Parker, MA
Johnson, D
Robinson, N
Horvath, G
Kadish, AH
机构
[1] NORTHWESTERN UNIV,DEPT MED,DIV CARDIOL,CHICAGO,IL 60611
[2] NORTHWESTERN UNIV,FEINBERG CARDIOVASC RES INST,CHICAGO,IL 60611
关键词
fast Fourier transform; ventricular fibrillation; implantable cardioverter defibrillator;
D O I
10.1111/j.1540-8167.1997.tb01010.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reproducibility of VF Characteristics. Introduction: The purpose of this study was to evaluate the immediate reproducibility off local electrogram characteristics recorded during repeated episodes of induced ventricular fibrillation (VF) in patients undergoing implantable cardioverter defibrillator (ICD) implantation. Methods and Results: Power spectral analysis (using a fast Fourier transform algorithm) of electrograms recorded during 3 seconds of VF were analyzed in 24 patients undergoing ICD implantation using a Medtronic Transvene lead, Patients had 2 to 7 episodes of VF that were induced during defibrillation threshold testing. VF was induced by burst pacing (n = 20) or T wave shock (n = 4). Simultaneous electrograms during VF were recorded from a Medtronic Transvene lead with the following configurations: (1) a narrow spaced (12 mm) dedicated bipole used clinically for sensing; (2) a unipolar electrogram from the right ventricular coil; and (3) a widely spaced (18.3 mm) integrated bipole using the distal tip and the coil. Intraclass correlation coefficients (ICCs) were determined to examine the reproducibility of these VF characteristics among VF episodes in each patient. Recordings from both bipolar configurations had ICCs from 0.40 to 0.55, whereas unipolar recordings ICCs were below 0.40. Reproducibility was similar for dedicated and integrated recordings. Conclusions: Frequency characteristics of repeated episodes of VF induced in the same subjects show fair-to-good but not excellent reproducibility. Bipolar recordings were far more reproducible than unipolar recordings, but both bipolar configurations had similar reproducibility. These findings have implications for both the pathophysiology of induced VF and the design of VF detection algorithms.
引用
收藏
页码:1209 / 1217
页数:9
相关论文
共 50 条
  • [1] Immediate reproducibility of upper limit of vulnerability measurements in patients undergoing transvenous implantable cardioverter defibrillator implantation
    Ellenbogen, KA
    Wood, MA
    Gilligan, DM
    Crofts, T
    London, W
    McClish, D
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1998, 9 (06) : 588 - 595
  • [2] Clinical characteristics and ventricular tachyarrhythmia events in patients with an implantable cardioverter defibrillator and atrial fibrillation
    Ammar, S.
    Streitner, F.
    Schoene, N.
    Veltmann, C.
    Schimpf, R.
    Wolpert, C.
    Borggrefe, M.
    Kuschyk, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 281 - 282
  • [3] INFLAMMATORY MARKERS IN PATIENTS UNDERGOING IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTATION FOR LIFE THREATENING VENTRICULAR ARRHYTHMIAS
    Papadopoulos, T.
    Katsiki, N.
    Dadous, G.
    Kanonidis, I.
    Sakadamis, G.
    ATHEROSCLEROSIS SUPPLEMENTS, 2010, 11 (02) : 104 - 105
  • [4] Implantable cardioverter defibrillator for alectinib induced ventricular fibrillation
    Mandal, Amit K. J.
    Stokes, Sarah A.
    Missouris, Constantinos G.
    CLINICAL TOXICOLOGY, 2020, 58 (07) : 781 - 784
  • [5] VENTRICULAR PACING THRESHOLD AND TIME TO CAPTURE POSTDEFIBRILLATION IN PATIENTS UNDERGOING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION
    KHASTGIR, T
    LATTUCA, J
    AARONS, D
    MURPHY, J
    OMARA, V
    JUANTEGUY, J
    VELTRI, EP
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (05): : 768 - 772
  • [6] Incidence and Predictors of Implantable Cardioverter-Defibrillator Therapy in Patients With Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy Undergoing Implantable Cardioverter-Defibrillator Implantation for Primary Prevention
    Bhonsale, Aditya
    James, Cynthia A.
    Tichnell, Crystal
    Murray, Brittney
    Gagarin, Dmitri
    Philips, Binu
    Dalal, Darshan
    Tedford, Ryan
    Russell, Stuart D.
    Abraham, Theodore
    Tandri, Harikrishna
    Judge, Daniel P.
    Calkins, Hugh
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (14) : 1485 - 1496
  • [7] Selective Left Ventricular Sensing Lead Implantation to Overcome Undersensing of Ventricular Fibrillation During Implantable Cardioverter Defibrillator Implantation
    Steinberg, Christian
    Philippon, Francois
    O'Hara, Gilles
    Molin, Franck
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (06) : 751.e3 - 751.e6
  • [8] The implantable cardioverter defibrillator prolongs survival in ventricular fibrillation patients who are revascularized
    Link, MS
    Cesarz, CA
    Costeas, XF
    Estes, NAM
    Wang, PJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 37126 - 37126
  • [9] Recurrent ventricular fibrillation caused by coronary artery spasm leading to implantable cardioverter defibrillator implantation
    Hendriks, Matthijs L.
    Allaart, Cornelis P.
    Bronzwaer, Jean G. F.
    Res, Jan J. C.
    de Cock, Carel C.
    EUROPACE, 2008, 10 (12): : 1456 - 1457
  • [10] Characteristics and Outcome of Patients with or without Previous Implantable Cardioverter Defibrillator Interventions Undergoing Ablation for Ventricular Tachycardia
    Bencardino, Gianluigi
    Narducci, Maria Lucia
    Scacciavillani, Roberto
    Gabrielli, Francesca Augusta
    Pelargonio, Gemma
    Massetti, Massimo
    Crea, Filippo
    Lanza, Gaetano Antonio
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (16)