Reproducibility of ventricular fibrillation characteristics in patients undergoing implantable cardioverter defibrillator implantation

被引:17
|
作者
Taneja, T
Goldberger, J
Parker, MA
Johnson, D
Robinson, N
Horvath, G
Kadish, AH
机构
[1] NORTHWESTERN UNIV,DEPT MED,DIV CARDIOL,CHICAGO,IL 60611
[2] NORTHWESTERN UNIV,FEINBERG CARDIOVASC RES INST,CHICAGO,IL 60611
关键词
fast Fourier transform; ventricular fibrillation; implantable cardioverter defibrillator;
D O I
10.1111/j.1540-8167.1997.tb01010.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reproducibility of VF Characteristics. Introduction: The purpose of this study was to evaluate the immediate reproducibility off local electrogram characteristics recorded during repeated episodes of induced ventricular fibrillation (VF) in patients undergoing implantable cardioverter defibrillator (ICD) implantation. Methods and Results: Power spectral analysis (using a fast Fourier transform algorithm) of electrograms recorded during 3 seconds of VF were analyzed in 24 patients undergoing ICD implantation using a Medtronic Transvene lead, Patients had 2 to 7 episodes of VF that were induced during defibrillation threshold testing. VF was induced by burst pacing (n = 20) or T wave shock (n = 4). Simultaneous electrograms during VF were recorded from a Medtronic Transvene lead with the following configurations: (1) a narrow spaced (12 mm) dedicated bipole used clinically for sensing; (2) a unipolar electrogram from the right ventricular coil; and (3) a widely spaced (18.3 mm) integrated bipole using the distal tip and the coil. Intraclass correlation coefficients (ICCs) were determined to examine the reproducibility of these VF characteristics among VF episodes in each patient. Recordings from both bipolar configurations had ICCs from 0.40 to 0.55, whereas unipolar recordings ICCs were below 0.40. Reproducibility was similar for dedicated and integrated recordings. Conclusions: Frequency characteristics of repeated episodes of VF induced in the same subjects show fair-to-good but not excellent reproducibility. Bipolar recordings were far more reproducible than unipolar recordings, but both bipolar configurations had similar reproducibility. These findings have implications for both the pathophysiology of induced VF and the design of VF detection algorithms.
引用
收藏
页码:1209 / 1217
页数:9
相关论文
共 50 条
  • [31] First ventricular fibrillation event in patients with Brugada syndrome treated with an implantable cardioverter-defibrillator
    Brugada, J
    Bartholomay, E
    Mont, L
    Brugada, R
    Brugada, P
    CIRCULATION, 2004, 110 (17) : 625 - 625
  • [32] Mode of onset of ventricular fibrillation in patients with Brugada syndrome detected by implantable cardioverter defibrillator therapy
    Kakishita, M
    Kurita, T
    Matsuo, K
    Taguchi, A
    Suyama, K
    Shimizu, W
    Aihara, N
    Kamakura, S
    Yamamoto, F
    Kobayashi, J
    Kosakai, Y
    Ohe, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (05) : 1646 - 1653
  • [33] Impact of atrial fibrillation in patients with implantable cardioverter-defibrillator
    Madrid, A
    Rebollo, JG
    Peña, G
    Rodriguez, A
    Cano, L
    Mejia, MA
    Moro, C
    Camino, A
    EUROPEAN HEART JOURNAL, 2001, 22 : 476 - 476
  • [34] Implantable cardioverter defibrillator events in patients with asymptomatic nonsustained ventricular tachycardia: Is device implantation justified?
    Russo, AM
    Nayak, H
    Verdino, R
    Springman, J
    Gerstenfeld, E
    Hsia, H
    Marchlinski, FE
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (12): : 2289 - 2295
  • [35] Clinical implications of left ventricular assist device implantation in patients with an implantable cardioverter-defibrillator
    Boudghene-Stambouli, Fanny
    Boule, Stephane
    Goeminne, Celine
    Botcherby, Edward
    Marquie, Christelle
    Kouakam, Claude
    Guedon-Moreau, Laurence
    Schurtz, Guillaume
    de Groote, Pascal
    Lamblin, Nicolas
    Fertin, Marie
    Robin, Emmanuel
    Brigadeau, Francois
    Klug, Didier
    Lacroix, Dominique
    Meurice, Jonathan
    Wissocque, Ludivine
    Vincentelli, Andre
    Kacet, Salem
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (02) : 177 - 184
  • [36] Propofol for implantable cardioverter defibrillator implantation in patients with Brugada syndrome
    Kwon, Hye-Mee
    Kim, Sung-Hoon
    Park, Se-Ung
    Rhim, Jin-Ho
    Park, Hee-Sun
    Kim, Wook-Jong
    Nam, Gi-Byoung
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (06): : 656 - 660
  • [37] Impact of atrial fibrillation on mortality in patients with an Implantable Cardioverter Defibrillator
    Rienstra, M
    Smit, MD
    Van Veldhuisen, DJ
    Wiesfeld, AC
    Van Dessel, PF
    Tan, ES
    Nieuwland, W
    Van den Berg, MP
    Van Gelder, IC
    CIRCULATION, 2004, 110 (17) : 704 - 704
  • [38] Clinical application of the fibrillation number in patients with an implantable cardioverter defibrillator
    Hwang, Minki
    Lee, Hancheol
    Lee, Young-Seon
    Chung, Soonwon
    Choi, Sung Hwan
    Shim, Eun Bo
    Pak, Hui-Nam
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2014, 116 (01): : 33 - 39
  • [39] Management of patients with pacemakers or implantable cardioverter defibrillator undergoing radiotherapy
    Huertas, A.
    Thuillot, M.
    Bibault, J. -E.
    Sharifzadehgan, A.
    Laurans, M.
    Giraud, P.
    Lavergne, T.
    Marijon, E.
    Durdux, C.
    CANCER RADIOTHERAPIE, 2018, 22 (6-7): : 515 - 521
  • [40] Implantable cardioverter-defibrillator therapy in patients with nonischemic ventricular tachycardia or -fibrillation and normal left ventricular function
    Wichter, T
    Block, M
    MartinezRubio, A
    Brunn, J
    Weber, M
    Bansch, D
    Borggrefe, M
    CIRCULATION, 1996, 94 (08) : 763 - 763