Bounded Kalman filter method for motion-robust, non-contact heart rate estimation

被引:37
|
作者
Prakash, Sakthi Kumar Arul [1 ]
Tucker, Conrad S. [2 ]
机构
[1] Penn State Univ, Dept Ind & Mfg Engn, State Coll, PA 16801 USA
[2] Penn State Univ, Dept Ind & Mfg Engn, SEDTAPP, State Coll, PA 16801 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2018年 / 9卷 / 02期
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
RATE MONITOR; SENSOR; NOISE;
D O I
10.1364/BOE.9.000873
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The authors of this work present a real-time measurement of heart rate across different lighting conditions and motion categories. This is an advancement over existing remote photo plethysmography (rPPG) methods that require a static, controlled environment for heart rate detection, making them impractical for real-world scenarios wherein a patient may be in motion, or remotely connected to a healthcare provider through telehealth technologies. The algorithm aims to minimize motion artifacts such as blurring and noise due to head movements (uniform, random) by employing i) a blur identification and denoising algorithm for each frame and ii) a bounded Kalman filter technique for motion estimation and feature tracking. A case study is presented that demonstrates the feasibility of the algorithm in non-contact estimation of the pulse rate of subjects performing everyday head and body movements. The method in this paper outperforms state of the art rPPG methods in heart rate detection, as revealed by the benchmarked results. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.
引用
收藏
页码:873 / 897
页数:25
相关论文
共 50 条
  • [41] Non-contact Heart Rate Measurement based on Camera Image
    Kitajima, Toshihiro
    Choi, SangOn
    Murakami, Edwardo Arata Y.
    JOURNAL OF INFORMATION ASSURANCE AND SECURITY, 2015, 10 (03): : 120 - 129
  • [42] Non-contact Heart Rate Monitoring with Mobile Phone Camera
    Lin, Shu-Yen
    Tsai, Meng-Ru
    2019 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS - TAIWAN (ICCE-TW), 2019,
  • [43] The Non-Contact Heart Rate Measurement System for Monitoring HRV
    Huang, Ji-Jer
    Yu, Sheng-, I
    Syu, Hao-Yi
    See, Aaron Raymond
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3238 - 3241
  • [44] Multi-Task Learning by Leveraging Non-Contact Heart Rate for Robust Facial Emotion Recognition
    Ji, Yerim
    Dong, Suh-Yeon
    IEEE ACCESS, 2024, 12 : 92175 - 92180
  • [45] Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
    Dosso, Yasmina Souley
    Greenwood, Kimberley J.
    Harrold, Joann
    Green, James R.
    IEEE ACCESS, 2023, 11 : 144168 - 144179
  • [46] Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability
    Parchani, Gaurav
    Kumar, Gulshan
    Rao, Raghavendra
    Udupa, Kaviraja
    Saran, Vibhor
    ANNALS OF NEUROSCIENCES, 2022, 29 (01) : 16 - 20
  • [47] Motion-Tolerant Non-Contact Heart-Rate Measurements from Radar Sensor Fusion
    Rong, Yu
    Dutta, Arindam
    Chiriyath, Alex
    Bliss, Daniel W.
    SENSORS, 2021, 21 (05) : 1 - 17
  • [48] Contact and Non-contact Heart Beat Rate Measurement Techniques: Challenges and Issues
    Khong, Wei Leong
    Mariappan, Muralindran
    Chong, Chee Siang
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2021, 29 (03): : 1707 - 1732
  • [49] Robust Estimation Based on the Least Absolute Deviations Method and the Kalman Filter
    Miller, B. M.
    Kolosov, K. S.
    AUTOMATION AND REMOTE CONTROL, 2020, 81 (11) : 1994 - 2010
  • [50] Robust Estimation Based on the Least Absolute Deviations Method and the Kalman Filter
    B. M. Miller
    K. S. Kolosov
    Automation and Remote Control, 2020, 81 : 1994 - 2010