Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability

被引:9
|
作者
Parchani, Gaurav [1 ]
Kumar, Gulshan [2 ]
Rao, Raghavendra [3 ]
Udupa, Kaviraja [2 ]
Saran, Vibhor [1 ]
机构
[1] Turtle Shell Technol Pvt Ltd, City Ctr 40,Ground & Mezzanine Floor, Bengaluru 560038, Karnataka, India
[2] Natl Inst Mental Hlth & Neuro Sci NIMHANS, Dept Neurophysiol, Bengaluru, Karnataka, India
[3] Cent Council Res Yoga & Naturopathy, Dept Res, Delhi, India
关键词
Autonomic nervous system balance; Ballistocardiography; Heart rate variability; Parasympathetic nervous system; Sympathetic nervous system;
D O I
10.1177/09727531211063426
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Functions of the autonomic nervous system have cardinal importance in day-to-day life. Heart rate variability (HRV) has been shown to estimate the functioning of the autonomic nervous system. Imbalance in the functioning of the autonomic nervous system is seen to be associated with chronic conditions such as chronic kidney disease, cardiovascular diseases, diabetes mellitus, and so on. Purpose: To evaluate the efficacy of a non-contact ballistocardiography (BCG) system to calculate HRV parameters by comparing them to the parameters derived from a standard commercial software that uses an electrocardiogram (ECG). Methods: Current study captured an ECG signal using a three-channel ECG Holter machine, whereas the BCG signal was captured using a BCG sensor sheet consisting of vibroacoustic sensors placed under the mattress of the participants of the study. Results: The study was conducted on 24 subjects for a total of 54 overnight recordings. The proposed method covered 97.92% epochs of the standard deviation of NN intervals (SDNN) and 99.27% epochs of root mean square of successive differences (RMSSD) within 20 ms and 30 ms tolerance, respectively, whereas 98.84% of two-min intervals for low-frequency (LF) to high-frequency (HF) ratio was covered within a tolerance of 1. Kendall's coefficient of concordance was also calculated, giving a P < .001 for all the three parameters and coefficients 0.66, 0.55, and 0.44 for SDNN, RMSSD, and LF/HF, respectively. Conclusion: The results show that HRV parameters captured using unobtrusive and non-invasive BCG sensors are comparable to HRV calculated using ECG.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [1] Non-contact measurement of the heart rate and the heart rate variability
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Drnovsek, Janko
    ELEKTROTEHNISKI VESTNIK, 2013, 80 (03): : 135 - 140
  • [2] Non-contact heart rate and heart rate variability measurements: A review
    Kranjec, J.
    Begus, S.
    Gersak, G.
    Drnovsek, J.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2014, 13 : 102 - 112
  • [3] Development of an Optical System for Non-Contact Type Measurement of Heart Rate and Heart Rate Variability
    Gondane, Jyoti
    Panse, Meena S.
    APPLIED SYSTEM INNOVATION, 2021, 4 (03)
  • [4] Non-contact measurement of mental stress via heart rate variability
    Chen, Fei
    Kong, Lingqin
    Zhao, Yuejin
    Dong, Liquan
    Liu, Ming
    Hui, Mei
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XLIII, 2020, 11510
  • [5] Design and Clinical Evaluation of a Non-Contact Heart Rate Variability Measuring Device
    Kranjec, Jure
    Begus, Samo
    Gersak, Gregor
    Sinkovec, Matjaz
    Drnovsek, Janko
    Hudoklin, Domen
    SENSORS, 2017, 17 (11)
  • [6] Non-contact and real-time measurement of heart rate and heart rate variability using microwave reflectometry
    Mase, A.
    Kogi, Y.
    Maruyama, T.
    Tokuzawa, T.
    Sakai, F.
    Kunugita, M.
    Koike, T.
    Hasegawa, H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2020, 91 (01):
  • [7] Study on non-contact heart rate monitor
    Nagasawa H.
    Sano M.
    1600, Japan Soc. of Med. Electronics and Biol. Engineering (58) : 590 - 591
  • [8] Using in-seat electrical potential sensors for non-contact monitoring of heart rate, heart rate variability, and heart rate recovery
    Stephenson, Alice C.
    Willis, Rachel
    Alford, Chris
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2021, 169 : 1 - 10
  • [9] Non-Contact Psychological Stress Detection Combining Heart Rate Variability and Facial Expressions
    Kong Lingqin
    Chen Fei
    Zhao Yuejin
    Dong Liquan
    Liu Ming
    Hui Mei
    ACTA OPTICA SINICA, 2021, 41 (03)
  • [10] UWB Radar for Non-contact Heart Rate Variability Monitoring and Mental State Classification
    Han, Yang
    Lauteslager, Timo
    Lande, Tor S.
    Constandinou, Timothy G.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 6578 - 6582