Comparison of two dose calculation methods applied to extracranial stereotactic radiotherapy treatment planning

被引:15
|
作者
Hansen, AT [1 ]
Petersen, JB
Hoyer, M
Christensen, JJ
机构
[1] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
关键词
extracraniel stereotactic radiotherapy; treatment planning; dose calculation algorithms; collapsed cone;
D O I
10.1016/j.radonc.2005.04.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Lung tissue is a special challenge for a dose calculation algorithm, especially in the case of extracranial stereotactic radiotherapy (ESRT) due to small field sizes in combination with large variations in tissue density. The present study investigates the choice of dose calculation algorithm for 18 patients with a single lung tumor and 8 patients with a single liver tumor. The dose calculation is performed with both the pencil beam convolution algorithm and the collapsed cone convolution algorithm with the same number of monitor units in both cases. In addition, the dose calculation with the collapsed cone convolution algorithm is also performed with modified field sizes in order to match the Planning Target Volume (PTV) peripheral dose of the pencil beam based treatment. Results: For liver tumors, the mean Clinical Target Volume (CTV) dose calculated by the collapsed cone convolution algorithm and the pencil beam convolution algorithm is almost identical. For lung tumors, the mean CTV dose determined by the collapsed cone convolution algorithm differs up to 20%. Plans obtained by the two algorithms have field sizes which differ up to 8 mm for the same number of monitor units and minimum dose to the lung PTV. Conclusions: The choice of dose calculation algorithm can have a large influence on a treatment plan for ESRT of the lungs. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:96 / 98
页数:3
相关论文
共 50 条
  • [41] Influence of respiration on dose calculation in stereotactic body radiotherapy of the lung
    Yamazaki R.
    Onimaru R.
    Katoh N.
    Inoue T.
    Nishioka T.
    Shirato H.
    Date H.
    Radiological Physics and Technology, 2014, 7 (2) : 284 - 289
  • [42] The calculation of an integral biologically effective dose in fractionated stereotactic radiotherapy
    Clark, BG
    Souhami, L
    Pla, C
    Bahary, JP
    Podgorsak, EB
    Fowler, J
    RADIOSURGERY 1995, 1996, 1 : 268 - 275
  • [43] Dosimetric comparison of treatment planning methods for breast boost radiotherapy
    James, H.
    Downes, S.
    Ramsey, N.
    Knights, W.
    Laker, R.
    Mackenzie, C.
    Venkitaraman, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S791 - S792
  • [44] Stereotactic radiotherapy of extracranial targets:: CT-simulation and accuracy of treatment in the stereotactic body frame
    Wulf, J
    Hädinger, U
    Oppitz, U
    Olshausen, B
    Flentje, M
    RADIOTHERAPY AND ONCOLOGY, 2000, 57 (02) : 225 - 236
  • [45] Phase I of the Planning Compared Study of the DEGRO AG ESRT (Extracranial Stereotactic Radiotherapy)
    Moustakis, C.
    Ernst, I.
    Eich, H. -T.
    Krieger, T.
    Nestle, U.
    Wiehle, R.
    Ganswindt, U.
    Duma, M. -N.
    Oechsner, M.
    Alheit, H.
    Blank, H.
    Kornhuber, C.
    Ostheimer, C.
    Guckenberger, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 : 39 - 39
  • [46] Influence of tumour movement on the definition of the planning volume in the extracranial stereotactic radiotherapy of lung tumours
    Zimmermann, F.
    Essler, M.
    Bundschuh, R. A.
    Schill, S.
    Schratzenstaller, U.
    Krause, B. J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 : 25 - 25
  • [47] Comparison of normal tissue dose calculation methods for epidemiological studies of radiotherapy patients
    Mille, Matthew M.
    Jung, Jae Won
    Lee, Choonik
    Kuzmin, Gleb A.
    Lee, Choonsik
    JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) : 775 - 792
  • [48] Dose Calculation Verification for Stereotactic Treatment Plan
    Schifter, D.
    Kanner, A.
    Corn, B.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [49] TREATMENT PLANNING IN EXTRACRANIAL STEREOTACTIC RADIOTHERAPY (ESRT) OF LUNG AND LIVER TUMORS 3DCRT OR RAPID ARC (RA)?
    Wulf, J.
    Van der Sluis, J. W.
    Neuenschwander, H.
    Andre, I.
    Oppitz, U.
    Thoeni, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 (12) : 725 - 725
  • [50] Radiation Planning Index for dose distribution evaluation in stereotactic radiotherapy
    Slosarek, Krzysztof
    Grzadziel, Aleksandra
    Szlag, Marta
    Bystrzycka, Joanna
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2008, 13 (04) : 182 - 186