Comparison of two dose calculation methods applied to extracranial stereotactic radiotherapy treatment planning

被引:15
|
作者
Hansen, AT [1 ]
Petersen, JB
Hoyer, M
Christensen, JJ
机构
[1] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
关键词
extracraniel stereotactic radiotherapy; treatment planning; dose calculation algorithms; collapsed cone;
D O I
10.1016/j.radonc.2005.04.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Lung tissue is a special challenge for a dose calculation algorithm, especially in the case of extracranial stereotactic radiotherapy (ESRT) due to small field sizes in combination with large variations in tissue density. The present study investigates the choice of dose calculation algorithm for 18 patients with a single lung tumor and 8 patients with a single liver tumor. The dose calculation is performed with both the pencil beam convolution algorithm and the collapsed cone convolution algorithm with the same number of monitor units in both cases. In addition, the dose calculation with the collapsed cone convolution algorithm is also performed with modified field sizes in order to match the Planning Target Volume (PTV) peripheral dose of the pencil beam based treatment. Results: For liver tumors, the mean Clinical Target Volume (CTV) dose calculated by the collapsed cone convolution algorithm and the pencil beam convolution algorithm is almost identical. For lung tumors, the mean CTV dose determined by the collapsed cone convolution algorithm differs up to 20%. Plans obtained by the two algorithms have field sizes which differ up to 8 mm for the same number of monitor units and minimum dose to the lung PTV. Conclusions: The choice of dose calculation algorithm can have a large influence on a treatment plan for ESRT of the lungs. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:96 / 98
页数:3
相关论文
共 50 条
  • [31] A vectorized Monte Carlo code for radiotherapy treatment planning dose calculation
    Weng, XJ
    Yan, YL
    Shu, HZ
    Wang, JW
    Jiang, SB
    Luo, LM
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (07): : N111 - N120
  • [32] Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning
    Li, JS
    Pawlicki, T
    Deng, J
    Jiang, SB
    Mok, E
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10): : 2969 - 2985
  • [33] Accuracy assessment of absorbed dose rate calculation: evaluation of two treatment planning systems for molecular radiotherapy
    Negrin, J. Fragoso
    Gil, A. Vergara
    Santoro, L.
    Vauclin, S.
    Pouget, J.
    Kotzki, P.
    Deshayes, E.
    Bardies, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S394 - S394
  • [34] Assessment the accuracy of dose calculation in build-up region for two radiotherapy treatment planning systems
    Farhood, Bagher
    Toossi, Mohammad Taghi Bahreyni
    Ghorbani, Mahdi
    Salari, Elahe
    Knaup, Courtney
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2017, 13 (06) : 968 - 973
  • [35] Determining the optimal block margin on the planning target volume for extracranial stereotactic radiotherapy
    Cardinale, RM
    Wu, QW
    Benedict, SH
    Kavanagh, BD
    Bunp, E
    Mohan, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (02): : 515 - 520
  • [36] STEREOTACTIC RADIOTHERAPY FOR LUNG TUMOURS: TREATMENT PRESCRIPTION USING MONTE CARLO DOSE CALCULATION
    Bolt, R.
    Van der Schaaf, A.
    Hollander, M.
    Widder, J.
    van't Veld, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S116 - S116
  • [37] TOWARD DOSE OPTIMIZATION FOR FRACTIONATED STEREOTACTIC RADIOTHERAPY FOR ACOUSTIC NEUROMAS: COMPARISON OF TWO DOSE COHORTS
    Andrews, David W.
    Werner-Wasik, Maria
    Den, Robert B.
    Paek, Sun Ha
    Downes-Phillips, Beverly
    Willcox, Thomas O.
    Bednarz, Greg
    Maltenfort, Mitchell
    Evans, James J.
    Curran, Walter J., Jr.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (02): : 419 - 426
  • [38] Evaluation of Automated Treatment Planning and Organ Dose Prediction for Lung Stereotactic Body Radiotherapy
    Ouyang, Zi
    Zhuang, Tingliang
    Marwaha, Gaurav
    Kolar, Matthew D.
    Qi, Peng
    Videtic, Gregory M.
    Stephans, Kevin L.
    Xia, Ping
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (10)
  • [39] Technical Assessment of an Automated Treatment Planning on Dose Escalation of Pancreas Stereotactic Body Radiotherapy
    Wang, Shuo
    Zheng, Dandan
    Lin, Chi
    Lei, Yu
    Verma, Vivek
    Smith, April
    Ma, Rongtao
    Enke, Charles A.
    Zhou, Sumin
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2019, 18 : 1 - 10
  • [40] Optimization of treatment plans for extracranial stereotactic lung radiotherapy - RTOG 0236
    Drzymala, R
    Yano, S
    Andl, G
    MEDICAL PHYSICS, 2005, 32 (06) : 2033 - 2033