Influence of respiration on dose calculation in stereotactic body radiotherapy of the lung

被引:2
|
作者
Yamazaki R. [1 ]
Onimaru R. [2 ]
Katoh N. [2 ]
Inoue T. [2 ]
Nishioka T. [3 ]
Shirato H. [2 ]
Date H. [3 ]
机构
[1] Graduate School of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku
[2] Department of Radiation Medicine, Hokkaido University School of Medicine, Kita-15, Nishi-7, Kita-ku
[3] Faculty of Health Sciences, Hokkaido University, Kita-12, Nishi-5, Kita-ku
关键词
Chest wall motion; Dose calculation; Lung tumor; Respiration; Stereotactic body radiotherapy;
D O I
10.1007/s12194-014-0263-4
中图分类号
学科分类号
摘要
Our purpose in this study was to evaluate the variation in calculated doses caused by respiration in stereotactic body radiotherapy (SBRT) of the lung. The study targeted ten patients who underwent SBRT for lung tumors. CT images were acquired during free breathing and in the inhalation and exhalation phases. We compared the CT image at inhalation with the image at exhalation so as to measure the change in lung volume, variation in the CT value, and displacement of the chest wall. The lung volume change was shown to be correlated with the maximum of the chest wall motion and with the variation in the CT value. A statistically significant difference was observed in the CT values between inhalation and exhalation (p < 0.05). The total dose variation at the isocenter was confined within ±2 %. However, the dose from individual beams can vary significantly when the chest wall moves more than 10 mm in natural breathing. © 2014 Japanese Society of Radiological Technology and Japan Society of Medical Physics.
引用
收藏
页码:284 / 289
页数:5
相关论文
共 50 条
  • [1] Impact of respiratory motion on the calculation of lung dose in stereotactic body radiotherapy
    Lawrence, K. S.
    Picone, J. R.
    Yang, T. J.
    Trumpore, S.
    Nath, R.
    Decker, R. H.
    Wilson, L. D.
    Chen, Z. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S675 - S676
  • [2] Optimizing dose prescription in stereotactic body radiotherapy for lung tumours using Monte Carlo dose calculation
    Widder, Joachim
    Hollander, Miranda
    Ubbels, Jan F.
    Bolt, Rene A.
    Langendijk, Johannes A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 94 (01) : 42 - 46
  • [3] Lung Locations Most Affected by Dose-Calculation Algorithms in CyberKnife Stereotactic Body Radiotherapy
    Huang, Yu-Jie
    Lin, Chih-Hsueh
    Chang, Hsiao-Han
    Ting, Hui-Min
    Chao, Pei-Ju
    Tsai, I-Hsing
    Liu, Chao-Hong
    Huang, Chun-Chieh
    Lee, Tsair-Fwu
    IEEE ACCESS, 2019, 7 : 170763 - 170773
  • [4] Influence of respiration on calculation and delivery of the prescribed dose in external radiotherapy
    Jacobs, I
    Vanregemorter, J
    Scalliet, P
    RADIOTHERAPY AND ONCOLOGY, 1996, 39 (02) : 123 - 128
  • [5] Volume Dose Prescription in Stereotactic Body Radiotherapy for Lung Cancer
    Terahara, A.
    Saotome, N.
    Miyamoto, K.
    Omori, M.
    EUROPEAN JOURNAL OF CANCER, 2011, 47 : S207 - S207
  • [6] INFLUENCE OF THE TUMOR DIAMETER, THE LUNG DENSITY AND THE DOSE CALCULATION ALGORITHM IN LUNG CANCER TREATED WITH STEREOTACTIC BODY IRRADIATION
    Gassa, F.
    Ayadi, M.
    Ginestet, C.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S409 - S410
  • [7] Influence of calculation model on dose distribution in stereotactic radiotherapy for pulmonary targets
    Haedinger, U
    Krieger, T
    Flentje, M
    Wulf, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01): : 239 - 249
  • [8] Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer
    Matsugi K.
    Nakamura M.
    Miyabe Y.
    Yamauchi C.
    Matsuo Y.
    Mizowaki T.
    Hiraoka M.
    Radiological Physics and Technology, 2013, 6 (1) : 233 - 240
  • [9] Dose Calculation Accuracy Using Cone-Beam CT (CBCT) for Lung Stereotactic Body Radiotherapy (SBRT)
    Xiong, W.
    Huang, Y.
    Gewanter, R.
    Dutta, P.
    Burman, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] On the dose to a moving target in stereotactic ablative body radiotherapy to lung tumors
    Feygelman, V.
    Dilling, T. J.
    Moros, E. G.
    Zhang, G. G.
    MICRO-MINI & NANO-DOSIMETRY & INNOVATIVE TECHNOLOGIES IN RADIATION THERAPY (MMND&ITRO2016), 2017, 777