Optimizing dose prescription in stereotactic body radiotherapy for lung tumours using Monte Carlo dose calculation

被引:15
|
作者
Widder, Joachim [1 ]
Hollander, Miranda [1 ]
Ubbels, Jan F. [1 ]
Bolt, Rene A. [1 ]
Langendijk, Johannes A. [1 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Radiat Oncol, NL-9700 RB Groningen, Netherlands
关键词
Dose prescription; Lung; Monte Carlo dose calculation; Stereotactic body radiotherapy; Stereotactic radiotherapy; STAGE-I; RADIATION-THERAPY; TARGET VOLUME; CANCER; RADIOABLATION; IRRADIATION; CARCINOMA; OUTCOMES; SCANS;
D O I
10.1016/j.radonc.2009.11.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To define a method of dose prescription employing Monte Carlo (MC) dose calculation in stereotactic body radiotherapy (SBRT) for lung tumours aiming at a dose as low as possible outside of the PTV. Methods and materials: Six typical T1 lung tumours - three small, three large - were constructed centrally, peripherally in the lung, and nearby the thoracic wall, respectively. For each of these, five treatment plans employing dynamic conformal arc technique were made in which the dose was prescribed to encompass the PTV with the prescription isodose level (PIL) set in a range between 50% and 80% of the isocenter dose. Three shells of respectively 10 mm thickness around the PTV were constructed to assess the dose in the tissues directly adjacent to the PTV. Results: The PTV was nicely covered (mean 98.8% +/- 0.9%) With favourable conformity indices (mean 1.09 +/- 0.1). Mean doses around the PTVs were 73% (+/-1.3%), 76% (+/-3.5%), and 85% (+/-5.1%) of the prescribed dose in shell I for PIL50%, PIL65%, and PIL80%, respectively: 40% (+/-2.6%), 44% (+/-5.1%), 54% (+/-9.3%) in shell 2; and 24% (+/-1.9%), 26% (+/-3.6%), 33% (+/-6.8%) in shell 3. All normal tissue doses including the integral dose were also consistently worst for PIL80%. Monitor units were 30% higher for PIL65%, and 70% higher for PIL50%, compared with PIL80%. Conclusions: To improve normal tissue sparing the dose should be prescribed at an isodose lower than 80% of the isocenter dose in SBRT when using conformal arc technique with MC dose calculation. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 94 (2010) 42-46
引用
收藏
页码:42 / 46
页数:5
相关论文
共 50 条
  • [1] STEREOTACTIC RADIOTHERAPY FOR LUNG TUMOURS: TREATMENT PRESCRIPTION USING MONTE CARLO DOSE CALCULATION
    Bolt, R.
    Van der Schaaf, A.
    Hollander, M.
    Widder, J.
    van't Veld, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S116 - S116
  • [2] OPTIMIZING DOSE PRESCRIPTION IN SBRT FOR LUNG LESIONS USING MONTE CARLO CALCULATION
    Widder, J.
    Hollander, M.
    Ubbels, F.
    Bolt, R.
    Langendijk, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S248 - S248
  • [3] Evaluation of 4D dose to a moving target with Monte Carlo dose calculation in stereotactic body radiotherapy for lung cancer
    Matsugi K.
    Nakamura M.
    Miyabe Y.
    Yamauchi C.
    Matsuo Y.
    Mizowaki T.
    Hiraoka M.
    [J]. Radiological Physics and Technology, 2013, 6 (1) : 233 - 240
  • [4] Volume Dose Prescription in Stereotactic Body Radiotherapy for Lung Cancer
    Terahara, A.
    Saotome, N.
    Miyamoto, K.
    Omori, M.
    [J]. EUROPEAN JOURNAL OF CANCER, 2011, 47 : S207 - S207
  • [5] Is Monte Carlo-Based Dose Calculation Algorithm Required for All Lung Tumors Treated with Stereotactic Body Radiotherapy?
    Saleh, H.
    TeNapel, M.
    Soultan, D.
    Smith, M.
    Edds, J.
    Wang, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E783 - E784
  • [6] Influence of respiration on dose calculation in stereotactic body radiotherapy of the lung
    Yamazaki R.
    Onimaru R.
    Katoh N.
    Inoue T.
    Nishioka T.
    Shirato H.
    Date H.
    [J]. Radiological Physics and Technology, 2014, 7 (2) : 284 - 289
  • [7] Harmonization of dose prescription for lung stereotactic radiotherapy
    Beldjoudi, Guillaume
    Bosson, Fanny
    Bernard, Vivien
    Puel, Lise-Marie
    Martel-Lafay, Isabelle
    Ayadi, Myriam
    Tanguy, Ronan
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 24 : 65 - 70
  • [8] Evaluation of ray tracing and Monte Carlo algorithms in dose calculation and clinical outcomes for robotic stereotactic body radiotherapy of lung cancers
    Braunstein, Steve E.
    Dionisio, Sebastian A.
    Lometti, Michael W.
    Pinnaduwage, Dilini S.
    Chuang, Cynthia F.
    Yom, Sue S.
    Gottschalk, Alexander R.
    Descovich, Martina
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2014, 3 (01): : 67 - 79
  • [9] Dose to lung tumours treated with stereotactic radiotherapy
    Christensen, JJ
    Hansen, AT
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S435 - S435
  • [10] Study of Dose Calculation Using Monte Carlo Method in Radiotherapy
    Gao, C.
    Chi, Z.
    Liu, D.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)