Harmonization of dose prescription for lung stereotactic radiotherapy

被引:1
|
作者
Beldjoudi, Guillaume [1 ]
Bosson, Fanny [1 ]
Bernard, Vivien [1 ]
Puel, Lise-Marie [1 ]
Martel-Lafay, Isabelle [1 ]
Ayadi, Myriam [1 ]
Tanguy, Ronan [1 ]
机构
[1] Ctr Leon Berard, 28 Rue Laennec, Lyon, France
关键词
Pulmonary SBRT; Dose prescription; Independent dose calculation; 4D-sum; Deformable; Cumulated dose to GTV; Robotic assisted radiotherapy; Dedicated linear accelerator; GTV-based prescription; PTV-based prescription; BODY RADIATION-THERAPY; MODULATED ARC THERAPY; RESPIRATORY MOTION; CANCER;
D O I
10.1016/j.phro.2022.09.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Pulmonary stereotactic treatments can be performed using dedicated linear accelerators as well as robotic-assisted units, and different strategies can be used for dose prescription. This study aimed to compare the doses received by the tumor with a gross tumor volume (GTV)-based prescription on D98%GTV using a robotic-assisted unit (method A) and planning target volume (PTV)-based prescription on D95%PTV using a dedicated linac (method B).Material & methods: Plans of 32 patients were collected for method A, and a dose of 3 x 18 Gy was prescribed using type A algorithm and recalculated using a Monte-Carlo (MC) algorithm. The plans were normalized to match D98%GTV with the mean D98%GTV of the cohort. The plans of 23 patients were collected for method B, and a dose of 3 x 18 Gy was prescribed to D95%PTV using a MC algorithm. A 4D-sum method was developed to estimate doses for PTV and GTV. For validation, all plans were recalculated using an independent MC double-check software. A dose harmonization on D98% GTV was determined for both methods.Results: For method A, mean doses were D2%GTV = 59.9 +/- 2.1 Gy, D50%GTV = 55.6 +/- 1.2 Gy, D98%GTV = 49.5 +/- 0.0 Gy. For method B, the reported doses were D2%GTV = 64.6 +/- 2.1 Gy, D50%GTV = 62.8 +/- 1.7 Gy, and D98%GTV= 60.0 +/- 1.7 Gy. The dose trade-off of D98%GTV = 55 Gy was obtained for both methods. For method A, it corresponded to a dose prescription of 3 x 20 Gy using type A algorithm, followed by rescaling to obtain D98%GTV = 55 Gy. For method B, it corresponded to a dose prescription of D95%PTV = 3 x 16.5 Gy using the MC algorithm.Conclusions: This study determined similar near-minimum doses D98% GTV of approximately 3 x 18.3 Gy (55 Gy) using a GTV-based prescription on a robotic-assisted unit (method A) and a PTV-based prescription on a dedicated linac (method B).
引用
收藏
页码:65 / 70
页数:6
相关论文
共 50 条
  • [1] Volume Dose Prescription in Stereotactic Body Radiotherapy for Lung Cancer
    Terahara, A.
    Saotome, N.
    Miyamoto, K.
    Omori, M.
    [J]. EUROPEAN JOURNAL OF CANCER, 2011, 47 : S207 - S207
  • [2] Stereotactic intracranial radiotherapy: Dose prescription
    Schlienger, M.
    Lartigau, E.
    Nataf, F.
    Mornex, F.
    Latorzeff, I.
    Lisbona, A.
    Mahe, M.
    [J]. CANCER RADIOTHERAPIE, 2012, 16 : S38 - S45
  • [3] STEREOTACTIC RADIOTHERAPY FOR LUNG TUMOURS: TREATMENT PRESCRIPTION USING MONTE CARLO DOSE CALCULATION
    Bolt, R.
    Van der Schaaf, A.
    Hollander, M.
    Widder, J.
    van't Veld, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S116 - S116
  • [4] Optimizing dose prescription in stereotactic body radiotherapy for lung tumours using Monte Carlo dose calculation
    Widder, Joachim
    Hollander, Miranda
    Ubbels, Jan F.
    Bolt, Rene A.
    Langendijk, Johannes A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 94 (01) : 42 - 46
  • [5] Dose to lung tumours treated with stereotactic radiotherapy
    Christensen, JJ
    Hansen, AT
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S435 - S435
  • [6] Comparison of prescription methods for stereotactic body radiotherapy in lung cancer
    Olivier, K.
    Vargas, C.
    Louis, D.
    Chang, D.
    Newlin, H.
    Liu, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S87 - S87
  • [7] Lung dose in stereotactic radiotherapy for lung tumors delivered with VMAT
    Janiszewska, M.
    Maciejczyk, A.
    Skrzypczynska, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S904 - S904
  • [8] Isotoxic dose prescription level strategies for stereotactic liver radiotherapy: the price of dose uniformity
    Hansen, Anders T.
    Poulsen, Per R.
    Hoyer, Morten
    Worm, Esben S.
    [J]. ACTA ONCOLOGICA, 2020, 59 (05) : 558 - 564
  • [9] Stereotactic single-dose radiotherapy of lung metastases
    Hof, Holger
    Hoess, Angelika
    Oetzel, Dieter
    Debus, Juergen
    Herfarth, Klaus
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2007, 183 (12) : 673 - 678
  • [10] Increasing the Therapeutic Ratio of Stereotactic Ablative Radiotherapy by Individualized Isotoxic Dose Prescription
    Zindler, Jaap D.
    Thomas, Charles R., Jr.
    Hahn, Stephen M.
    Hoffmann, Aswin L.
    Troost, Esther G. C.
    Lambin, Philippe
    [J]. JNCI-JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2016, 108 (02)