Spatial Resolution of the Multiple Coincidences Compton Camera

被引:0
|
作者
Andreyev, Andriy [1 ]
Sitek, Arkadiusz [2 ]
Celler, Anna [1 ]
机构
[1] Univ British Columbia, Med Imaging Res Grp, Vancouver, BC V5Z 1M9, Canada
[2] Brigham & Womens Hosp, Harvard Med Sch, Dept Radiol, Boston, MA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we investigate the limits of spatial image resolution of Multiple Coincidences Compton Camera (MCCC). This technique is based on a simultaneous acquisition of several gammas emitted in cascade from a single nucleus. Contrary to a standard Compton camera, MCCC can theoretically provide a location of a radioactive source without complicated tomographic reconstruction. The commonly mentioned disadvantage of this method is the low probability of coincident triple gamma detection, which is necessary for the source localization. In this paper we investigate an additional fundamental restriction of the multiple coincidence approach which seriously limits the image resolution that can be achieved by MCCC. Our results suggest that it is possible to get better result in terms of spatial image resolution by reconstructing the Compton camera data without multiple coincidence principle than when using the MCCC concept.
引用
收藏
页码:2099 / 2103
页数:5
相关论文
共 50 条
  • [41] Multiple nuclide imaging in live mouse using semiconductor Compton camera for multiple molecular Imaging
    Motomura, Shinji
    Kanayama, Yousuke
    Haba, Hiromitsu
    Watanabe, Yasuyoshi
    Enomoto, Shuichi
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3741 - +
  • [42] ANGULAR CORRELATION OF BETA-GAMMA COINCIDENCES IN COMPTON EFFECT
    VANNAME, FW
    KOCH, JW
    CANADIAN JOURNAL OF PHYSICS, 1961, 39 (08) : 1212 - &
  • [43] Monte Carlo study of spatial resolution of the scintillation camera
    ZHU Jie 1
    2 College of Material Science and Technology
    Science China(Technological Sciences), 2011, (09) : 2373 - 2376
  • [44] Monte Carlo study of spatial resolution of the scintillation camera
    Zhu Jie
    Ouyang XiaoPing
    Chen Da
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2011, 54 (09) : 2373 - 2376
  • [45] SPATIAL RESOLUTION IN A MULTI-FOCUS PLENOPTIC CAMERA
    Damghanian, M.
    Olsson, R.
    Sjostrom, M.
    Erdmann, A.
    Perwass, C.
    2014 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2014, : 1932 - 1936
  • [46] Monte Carlo study of spatial resolution of the scintillation camera
    ZHU Jie OUYANG XiaoPing CHEN Da Northwest Institute of Nuclear TechnologyXian China College of Material Science and TechnologyNanjing University of Aeronautics and AstronauticsNanjing China
    Science China(Technological Sciences), 2011, 54 (09) : 2373 - 2376
  • [47] The Effect of Energy on Scintillation Camera Intrinsic Spatial Resolution
    Holstensson, M.
    Partridge, M.
    Buckley, S. E.
    Flux, G. D.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4084 - +
  • [48] Monte Carlo study of spatial resolution of the scintillation camera
    Jie Zhu
    XiaoPing Ouyang
    Da Chen
    Science China Technological Sciences, 2011, 54 : 2373 - 2376
  • [49] TOWARD SPATIAL TRACKING IN MULTIPLE CAMERA ENVIRONMENT
    Dai, Xiaochen
    Payandeh, Shahram
    2010 23RD CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2010,
  • [50] AN EXPERIMENTAL DETERMINATION OF OVERALL SPATIAL RESOLUTION OF A SCINTILLATION CAMERA
    CRADDUCK, TD