In this paper we investigate the limits of spatial image resolution of Multiple Coincidences Compton Camera (MCCC). This technique is based on a simultaneous acquisition of several gammas emitted in cascade from a single nucleus. Contrary to a standard Compton camera, MCCC can theoretically provide a location of a radioactive source without complicated tomographic reconstruction. The commonly mentioned disadvantage of this method is the low probability of coincident triple gamma detection, which is necessary for the source localization. In this paper we investigate an additional fundamental restriction of the multiple coincidence approach which seriously limits the image resolution that can be achieved by MCCC. Our results suggest that it is possible to get better result in terms of spatial image resolution by reconstructing the Compton camera data without multiple coincidence principle than when using the MCCC concept.
引用
收藏
页码:2099 / 2103
页数:5
相关论文
共 50 条
  • [21] Resolution recovery for Compton camera using origin ensemble algorithm
    Andreyev, A.
    Celler, A.
    Ozsahin, I.
    Sitek, A.
    MEDICAL PHYSICS, 2016, 43 (08) : 4866 - 4876
  • [22] Analysis and simultion. for Compton camera's imaging resolution
    Song Zhang-Yong
    Yu De-Yang
    Cai Xiao-Hong
    ACTA PHYSICA SINICA, 2019, 68 (11)
  • [23] Resolution Recovery for Compton Camera Using Origin Ensemble Algorithm
    Andreyev, Andriy
    Celler, Anna
    Sitek, Arkadiusz
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2774 - 2778
  • [24] INCREASED GAMMA-CAMERA RESOLUTION BY WEIGHTED COMPTON SUBTRACTION
    BERBERICH, R
    BRILL, G
    SCHMIDT, EL
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1984, 15 (05): : 246 - &
  • [25] IBIS Compton mode: Analysis of the random coincidences
    Segreto, A
    PROCEEDINGS OF THE 5TH INTEGRAL WORKSHOP ON THE INTEGRAL UNIVERSE, 2004, 552 : 893 - 896
  • [26] IBIS compton mode: Subtraction of the random coincidences
    Segreto, A
    PROCEEDINGS OF THE 5TH INTEGRAL WORKSHOP ON THE INTEGRAL UNIVERSE, 2004, 552 : 887 - 892
  • [27] PROTOTYPE DESIGN OF MULTIPLE COMPTON GAMMA-RAY CAMERA
    KAMAE, T
    HANADA, N
    ENOMOTO, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) : 352 - 355
  • [28] Multiple scattering Compton camera with neutron activation for material inspection
    Lee, Taewoong
    Lee, Wonho
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 784 : 423 - 429
  • [29] First application of the super -resolution imaging technique using a Compton camera
    Sato, S.
    Kataoka, J.
    Kotoku, J.
    Taki, M.
    Oyama, A.
    Tagawa, L.
    Fujieda, K.
    Nishi, F.
    Toyoda, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 969
  • [30] IMPROVING THE SPATIAL-RESOLUTION OF THE MULTIPLE MULTIWIRE PROPORTIONAL CHAMBER GAMMA-CAMERA
    BATEMAN, JE
    CONNOLLY, JF
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03): : 639 - 642