Spatial Resolution of the Multiple Coincidences Compton Camera

被引:0
|
作者
Andreyev, Andriy [1 ]
Sitek, Arkadiusz [2 ]
Celler, Anna [1 ]
机构
[1] Univ British Columbia, Med Imaging Res Grp, Vancouver, BC V5Z 1M9, Canada
[2] Brigham & Womens Hosp, Harvard Med Sch, Dept Radiol, Boston, MA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we investigate the limits of spatial image resolution of Multiple Coincidences Compton Camera (MCCC). This technique is based on a simultaneous acquisition of several gammas emitted in cascade from a single nucleus. Contrary to a standard Compton camera, MCCC can theoretically provide a location of a radioactive source without complicated tomographic reconstruction. The commonly mentioned disadvantage of this method is the low probability of coincident triple gamma detection, which is necessary for the source localization. In this paper we investigate an additional fundamental restriction of the multiple coincidence approach which seriously limits the image resolution that can be achieved by MCCC. Our results suggest that it is possible to get better result in terms of spatial image resolution by reconstructing the Compton camera data without multiple coincidence principle than when using the MCCC concept.
引用
收藏
页码:2099 / 2103
页数:5
相关论文
共 50 条
  • [31] Camera-motion and effective spatial resolution
    Xiao, Feng
    Silverstein, Amnon
    Farrell, Joyce
    ICIS '06: INTERNATIONAL CONGRESS OF IMAGING SCIENCE, FINAL PROGRAM AND PROCEEDINGS: LINKING THE EXPLOSION OF IMAGING APPLICATIONS WITH THE SCIENCE AND TECHNOLOGY OF IMAGING, 2006, : 33 - +
  • [32] Compton Camera Imaging
    Ikeda, Shiro
    Odaka, Hirokazu
    Uemura, Makoto
    Takahashi, Tadayuki
    Watanabe, Shin
    Takeda, Shin'ichiro
    2013 SEVENTH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2013, : 674 - 677
  • [33] Angular uncertainties due to geometry and spatial resolution in Compton cameras
    Ordonez, Caesar E.
    Chang, Wei
    Bolozdynya, Alexander
    IEEE Transactions on Nuclear Science, 1999, 46 (4 II): : 1142 - 1147
  • [34] MULTIPLE COMPTON-SCATTERING GAMMA-RAY IMAGING CAMERA
    DOGAN, N
    WEHE, DK
    KNOLL, GF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 299 (1-3): : 501 - 506
  • [35] Angular uncertainties due to geometry and spatial resolution in compton cameras
    Ordonez, CE
    Chang, W
    Bolozdynya, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (04) : 1142 - 1147
  • [36] A novel method improving the imaging resolution of a table-top Compton camera
    Seo, Hee
    Lee, Se Hyung
    Jeong, Jong Hwi
    Lee, Ju Hahn
    Lee, Chun Sik
    Lee, Jae Sung
    Kim, Chan Hyeong
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2972 - +
  • [37] Effect of position resolution on LoR discrimination for a dual-head Compton camera
    Gillam, John E.
    Beveridge, Toby E.
    Boston, Andrew J.
    Boston, Helen C.
    Cooper, Reynold J.
    Hall, Chris J.
    Mather, Andrew R.
    Nolan, Paul J.
    Lewis, Rob A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 76 - 79
  • [38] SUBMILLIMETER NUCLEAR MEDICAL IMAGING WITH A COMPTON CAMERA USING TRIPLE COINCIDENCES OF COLLINEAR BETA plus -ANNIHILATION PHOTONS AND GAMMA RAYS
    Lang, C.
    Habs, D.
    Thirolf, P.
    Zoglauer, A.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S30 - S30
  • [39] SPECTROMETER OF MULTIPLE COINCIDENCES
    PETROV, BF
    KRAFT, OE
    NAUMOV, YV
    OSTAPENKO, SA
    IZVESTIYA AKADEMII NAUK SSSR SERIYA FIZICHESKAYA, 1980, 44 (09): : 1970 - 1982
  • [40] ESTIMATION OF MULTIPLE COINCIDENCES
    VINCENT, CH
    NUCLEAR INSTRUMENTS & METHODS, 1975, 127 (03): : 421 - 427