Spatial Resolution of the Multiple Coincidences Compton Camera

被引:0
|
作者
Andreyev, Andriy [1 ]
Sitek, Arkadiusz [2 ]
Celler, Anna [1 ]
机构
[1] Univ British Columbia, Med Imaging Res Grp, Vancouver, BC V5Z 1M9, Canada
[2] Brigham & Womens Hosp, Harvard Med Sch, Dept Radiol, Boston, MA USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper we investigate the limits of spatial image resolution of Multiple Coincidences Compton Camera (MCCC). This technique is based on a simultaneous acquisition of several gammas emitted in cascade from a single nucleus. Contrary to a standard Compton camera, MCCC can theoretically provide a location of a radioactive source without complicated tomographic reconstruction. The commonly mentioned disadvantage of this method is the low probability of coincident triple gamma detection, which is necessary for the source localization. In this paper we investigate an additional fundamental restriction of the multiple coincidence approach which seriously limits the image resolution that can be achieved by MCCC. Our results suggest that it is possible to get better result in terms of spatial image resolution by reconstructing the Compton camera data without multiple coincidence principle than when using the MCCC concept.
引用
收藏
页码:2099 / 2103
页数:5
相关论文
共 50 条
  • [1] Study on the Spatial Resolution of Single and Multiple Coincidences Compton Camera
    Andreyev, Andriy
    Sitek, Arkadiusz
    Celler, Anna
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 1920 - 1926
  • [2] Reconstructed Image Resolution in Multiple Coincidences Compton Camera
    Andreyev, Andriy
    Celler, Anna
    Sitek, Arkadiusz
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3025 - +
  • [3] Reconstructed Image Spatial Resolution of Multiple Coincidences Compton Imager
    Andreyev, Andriy
    Sitek, Arkadiusz
    Celler, Anna
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 151 - 159
  • [4] Compton camera coincidences in the silicon drift detector
    Çonka-Nurdan, T
    Nurdan, K
    Walenta, AH
    Chiosa, I
    Freisleben, B
    Pavel, NA
    Strüder, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3839 - 3843
  • [5] First results on Compton camera coincidences with the silicon drift detector
    Çonka-Nurdan, T
    Nurdan, K
    Walenta, AH
    Chiosa, I
    Freisleben, B
    Pavel, NA
    Strüder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1381 - 1385
  • [6] EFFICIENCY AND ANGULAR RESOLUTION CALCULATIONS FOR A PROTOTYPE MULTIPLE COMPTON SCATTER CAMERA
    DOGAN, N
    WEHE, DK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 345 (02): : 296 - 302
  • [7] Resolution Recovery for Compton Camera based on Monte Carlo Spatial Sampling Method
    Yao, Zhiyang
    Xiao, Yongshun
    Wang, Bo
    Hou, Qinhan
    Chen, Zhiqiang
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [8] Resolution recovery reconstruction for a Compton camera
    Kim, Soo Mee
    Seo, Hee
    Park, Jin Hyung
    Kim, Chan Hyeong
    Lee, Chun Sik
    Lee, Soo-Jin
    Lee, Dong Soo
    Lee, Jae Sung
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (09): : 2823 - 2840
  • [9] First coincidences in pre-clinical Compton camera prototype for medical imaging
    Studen, A
    Burdette, D
    Chesi, E
    Cindro, V
    Clinthorne, NH
    Dulinski, W
    Fuster, J
    Han, L
    Kagan, H
    Lacasta, C
    Llosá, G
    Marques, AC
    Malakhov, N
    Meier, D
    Mikuz, M
    Park, SJ
    Roe, S
    Rogers, WL
    Steinberg, J
    Weilhammer, P
    Wilderman, SJ
    Zhang, L
    Zontar, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 531 (1-2): : 258 - 264
  • [10] A New Compton Camera Imaging Model to Mitigate the Finite Spatial Resolution of Detectors and New Camera Designs for Implementation
    Smith, Bruce
    TECHNOLOGIES, 2015, 3 (04): : 219 - 237