We show that the Casimir force (CF) gradient can be measured with no contact involved. Results of the CF measurement with systematic uncertainty of 3% are presented for the distance range of 100-600 nm. The statistical uncertainty is shown to be due to the thermal fluctuations of the force probe. The corresponding signal-to-noise ratio equals unity at the distance of 600 nm. Direct contact between surfaces used in most previous studies to determine absolute distance separation is here precluded. Use of direct contact to identify the origin of distances is a severe limitation for studies of the CF on structured surfaces as it deteriorates irreversibly the studied surface and the probe. This force machine uses a dynamical method with an inserted gold sphere probe glued to a lever. The lever is mechanically excited at resonant frequency in front of a chosen sample. The absolute distance determination is achieved to be possible, without any direct probe/sample contact, using an electrostatic method associated to a real time correction of the mechanical drift. The positioning shift uncertainty is as low as 2 nm. Use of this instrument to probe a very thin film of gold (10 nm) reveals important spatial variations in the measurement. Copyright (C) EPLA, 2009
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Non-contact non-resonant atomic force microscopy method for measurements of highly mobile molecules and nanoparticles
    Ukraintsev, Egor
    Rezek, Bohuslav
    ULTRAMICROSCOPY, 2023, 253
  • [42] Contrast inversion in non-contact Dynamic Scanning Force Microscopy: What is high and what is low?
    Palacios-Lidon, E.
    Munuera, C.
    Ocal, C.
    Colchero, J.
    ULTRAMICROSCOPY, 2010, 110 (07) : 789 - 800
  • [43] Analysis of magnetic force and dynamic characteristic for non-contact permanent magnet linear drive device
    Zhao, Chuan
    Sun, Feng
    Jin, Junjie
    Bo, Mingwei
    Xu, Fangchao
    Zhang, Xiaoyou
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2020, 64 (1-4) : 1337 - 1345
  • [44] Progressive damage detection using non-contact measurements
    Venkatappa, S
    Petro, S
    Chen, SE
    GangaRao, H
    STRUCTURAL MATERIALS TECHNOLOGY III: AN NDT CONFERENCE, 1998, 3400 : 70 - 81
  • [45] Contact and air-coupled (non-contact) ultrasonic attenuation and speed for quantitative measurements and imaging of bone in-vivo
    Ganezer, K
    Hurst, K
    Krmar, M
    Nunez, D
    Shukla, S
    MEDICAL PHYSICS, 2004, 31 (06) : 1747 - 1747
  • [46] Non-contact strain measurements based on inverse magnetostriction
    Bechtold, Christoph
    Teliban, Iulian
    Thede, Claas
    Chemnitz, Steffen
    Quandt, Eckhard
    SENSORS AND ACTUATORS A-PHYSICAL, 2010, 158 (02) : 224 - 230
  • [47] Verification of multiband system for non-contact emissivity measurements
    Mazikowski, Adam
    OPTOELECTRONIC AND ELECTRONIC SENSORS VI, 2006, 6348
  • [48] Non-contact ultrasonic quality measurements of food products
    Gan, Tat Hean
    Pallav, Prakash
    Hutchins, David A.
    JOURNAL OF FOOD ENGINEERING, 2006, 77 (02) : 239 - 247
  • [49] Uncertainty evaluation in non-contact aperture area measurements
    Razet, A.
    Bastie, J.
    METROLOGIA, 2006, 43 (05) : 361 - 366
  • [50] A Non-contact Directional Sensor for Partial Discharge Measurements
    Sack, Kevin
    Su, Charles Q.
    CONFERENCE RECORD OF THE 2010 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION (ISEI), 2010,