Quantitative non-contact dynamic Casimir force measurements

被引:71
|
作者
Jourdan, G. [1 ,2 ,3 ]
Lambrecht, A. [3 ]
Comin, F. [4 ]
Chevrier, J. [1 ,2 ,4 ]
机构
[1] UJF, CNRS, Inst Neel, F-38042 Grenoble 9, France
[2] Univ Grenoble 1, F-38041 Grenoble 9, France
[3] UPMC, ENS, CNRS, Lab Kastler Brossel, F-75252 Paris 05, France
[4] ESRF, F-38043 Grenoble, France
关键词
SILICON;
D O I
10.1209/0295-5075/85/31001
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We show that the Casimir force (CF) gradient can be measured with no contact involved. Results of the CF measurement with systematic uncertainty of 3% are presented for the distance range of 100-600 nm. The statistical uncertainty is shown to be due to the thermal fluctuations of the force probe. The corresponding signal-to-noise ratio equals unity at the distance of 600 nm. Direct contact between surfaces used in most previous studies to determine absolute distance separation is here precluded. Use of direct contact to identify the origin of distances is a severe limitation for studies of the CF on structured surfaces as it deteriorates irreversibly the studied surface and the probe. This force machine uses a dynamical method with an inserted gold sphere probe glued to a lever. The lever is mechanically excited at resonant frequency in front of a chosen sample. The absolute distance determination is achieved to be possible, without any direct probe/sample contact, using an electrostatic method associated to a real time correction of the mechanical drift. The positioning shift uncertainty is as low as 2 nm. Use of this instrument to probe a very thin film of gold (10 nm) reveals important spatial variations in the measurement. Copyright (C) EPLA, 2009
引用
收藏
页数:5
相关论文
共 50 条
  • [31] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURGER, A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1974, 51 (04): : 282 - 285
  • [32] Optical methods for non-contact measurements of membranes
    Roose, S.
    Stockman, Y.
    Rochus, P.
    Kuhn, T.
    Lang, M.
    Baier, H.
    Langlois, S.
    Casarosa, G.
    ACTA ASTRONAUTICA, 2009, 65 (9-10) : 1317 - 1329
  • [33] In situ non-contact measurements of surface roughness
    Quinsat, Yann
    Tournier, Christophe
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2012, 36 (01): : 97 - 103
  • [34] Non-contact anthropometric measurements in newborn patients
    Burini, Sara
    Marchionni, Paolo
    Scalise, Lorenzo
    Spinsante, Susanna
    Ferretti, Enrica
    Carnielli, Virgilio Paolo
    2020 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2020,
  • [35] Ensuring the accuracy of non-contact temperature measurements
    Rols, Joris
    Electronics World, 2022, 127 (2013): : 22 - 23
  • [36] Parameter estimation in dynamic Casimir force measurements with known periodicity
    Cui, Song
    Soh, Yeng Chai
    PHYSICS LETTERS A, 2011, 376 (02) : 109 - 113
  • [37] Mechanisms of dynamic force microscopy on polyvinyl alcohol: region-specific non-contact and intermittent contact regimes
    Haugstad, G
    Jones, RR
    ULTRAMICROSCOPY, 1999, 76 (1-2) : 77 - 86
  • [38] Sonorheometry for non-contact dynamic assessment of thrombosis
    不详
    BIORHEOLOGY, 2005, 42 (1-2) : 44 - 44
  • [39] Thermally driven non-contact atomic force microscopy
    Gannepalli, A
    Sebastian, A
    Cleveland, J
    Salapaka, M
    APPLIED PHYSICS LETTERS, 2005, 87 (11)
  • [40] MODELING AND SIMULATION OF NON-CONTACT ATOMIC FORCE MICROSCOPE
    Bahrami, Mohammadreza
    Ramezani, Asghar
    Osquie, Kambiz Ghaemi
    PROCEEDINGS OF THE ASME 10TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2010, VOL 5, 2010, : 565 - 569