Quantitative non-contact dynamic Casimir force measurements

被引:71
|
作者
Jourdan, G. [1 ,2 ,3 ]
Lambrecht, A. [3 ]
Comin, F. [4 ]
Chevrier, J. [1 ,2 ,4 ]
机构
[1] UJF, CNRS, Inst Neel, F-38042 Grenoble 9, France
[2] Univ Grenoble 1, F-38041 Grenoble 9, France
[3] UPMC, ENS, CNRS, Lab Kastler Brossel, F-75252 Paris 05, France
[4] ESRF, F-38043 Grenoble, France
关键词
SILICON;
D O I
10.1209/0295-5075/85/31001
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
We show that the Casimir force (CF) gradient can be measured with no contact involved. Results of the CF measurement with systematic uncertainty of 3% are presented for the distance range of 100-600 nm. The statistical uncertainty is shown to be due to the thermal fluctuations of the force probe. The corresponding signal-to-noise ratio equals unity at the distance of 600 nm. Direct contact between surfaces used in most previous studies to determine absolute distance separation is here precluded. Use of direct contact to identify the origin of distances is a severe limitation for studies of the CF on structured surfaces as it deteriorates irreversibly the studied surface and the probe. This force machine uses a dynamical method with an inserted gold sphere probe glued to a lever. The lever is mechanically excited at resonant frequency in front of a chosen sample. The absolute distance determination is achieved to be possible, without any direct probe/sample contact, using an electrostatic method associated to a real time correction of the mechanical drift. The positioning shift uncertainty is as low as 2 nm. Use of this instrument to probe a very thin film of gold (10 nm) reveals important spatial variations in the measurement. Copyright (C) EPLA, 2009
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Non-contact bimodal magnetic force microscopy
    Schwenk, J.
    Marioni, M.
    Romer, S.
    Joshi, N. R.
    Hug, H. J.
    APPLIED PHYSICS LETTERS, 2014, 104 (11)
  • [22] Contact and non-contact mode imaging by atomic force microscopy
    Morita, S
    Fujisawa, S
    Kishi, E
    Ohta, M
    Ueyama, H
    Sugawara, Y
    THIN SOLID FILMS, 1996, 273 (1-2) : 138 - 142
  • [23] Contact-Force Versus Non-Contact Force Sensing Catheter Complications: A Disturbance in the Force?
    Sharma, Esseim
    Chu, Antony F.
    CIRCULATION, 2017, 136
  • [24] Non-contact Quantitative Diffuse Reflectance Spectroscopy
    Sorgato, Veronica
    Berger, Michel
    Emain, Charlotte
    Koenig, Anne
    Roig, Blandine
    Vever-Bizet, Christine
    Dinten, Jean-Marc
    Bourg-Heckly, Genevieve
    Planat-Chretien, Anne
    DIFFUSE OPTICAL IMAGING V, 2015, 9538
  • [25] Non-contact dynamic mode atomic force microscope: Effects of nonlinear atomic forces
    Das, Soma
    Sreeram, P. A.
    2006 IEEE CONFERENCE ON EMERGING TECHNOLOGIES - NANOELECTRONICS, 2006, : 458 - +
  • [26] A Specimen-Tracking Controller for the Transverse Dynamic Force Microscope in Non-Contact Mode
    Hatano, T.
    Zhang, K.
    Khan, S. G.
    Nguyen, T.
    Herrmann, G.
    Edwards, C.
    Burgess, S. C.
    Miles, M.
    2016 AMERICAN CONTROL CONFERENCE (ACC), 2016, : 7384 - 7389
  • [27] CLINICAL TONOMETRIC MEASUREMENTS WITH NON-CONTACT TONOMETER
    AUGSBURG.A
    POLASKY, M
    WALBY, M
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (09): : 743 - 743
  • [28] Preamplifiers for non-contact capacitive biopotential measurements
    Peng, GuoChen
    Ignjatovic, Zeljko
    Bocko, Mark F.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1482 - 1485
  • [29] Continuous non-contact river discharge measurements
    Cheng, RT
    Costa, JE
    Mason, RR
    Plant, WJ
    Gartner, JW
    Spicer, K
    Haeni, FP
    Melcher, N
    PROCEEDINGS OF THE NINTH INTERNATIONAL SYMPOSIUM ON RIVER SEDIMENTATION, VOLS 1-4, 2004, : 2535 - 2542
  • [30] Non-contact ultrasonic measurements in food materials
    Saggin, R
    Coupland, JN
    FOOD RESEARCH INTERNATIONAL, 2001, 34 (10) : 865 - 870