Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study

被引:4
|
作者
Galal, Sherif [1 ,2 ]
Mattar, Yasser [1 ]
Solyman, Alaa Mohy Eldin [1 ]
Ezzat, Mostafa [1 ]
机构
[1] Cairo Univ, Fac Med, Dept Orthopaed Surg, Cairo 11559, Egypt
[2] Hosp Special Surg, Dept Orthopaed Surg, 535 E 70th St, New York, NY 10021 USA
关键词
Distal humerus; Fracture; Fixation; Locking plates; Randomized controlled; INTERNAL-FIXATION; INTERCONDYLAR FRACTURES; OPEN REDUCTION;
D O I
10.1007/s00264-020-04770-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Studies have shown that the use of nonlocking (reconstruction) plates in fixing distal humerus fractures may not yield stable fixation which therefore requires long immobilization and suboptimal functional results. There are reports showing that locking plates are biomechanically superior to nonlocking plates. The aim of this study was to compare elbow functional outcomes between locking and nonlocking plates in fixation of distal humerus fractures. Methods A single-centre, randomized control study was conducted at an academic level 1 trauma centre. A total of 60 patients with type 13-A fracture (AO/OTA classification) were randomized into two equal groups, locking plates group, and nonlocking plates group. The primary outcome measure was the Mayo elbow performance score (MEPS) at one year. Secondary outcomes measures were elbow flexion/extension arc, union, operative time, and complications (e.g., infection, heterotrophic ossification). Results The Mayo Elbow Performance Score (MEPS) at one year was 88 +/- 10.1 in locking plates group and 75.8 +/- 12.8 in nonlocking plates group. The difference was found to be statically significant (Pvalue = 0.01). Elbow flexion/extension arc of motion at one year was 116 degrees +/- 15 degrees in locking plates group and 113 degrees +/- 28 degrees in nonlocking plates. The difference was not found to be statistically significant (Pvalue = 0.17). Conclusion Both implants yield similar results, with locking plates showing slightly better clinical scores.
引用
收藏
页码:2761 / 2767
页数:7
相关论文
共 50 条
  • [41] A comparison of outcomes of locking versus non-locking plate fixation for the distal fibula fractures: a systematic review and meta-analysis
    Dhillon, Mandeep Singh
    Rajnish, Rajesh Kumar
    Kumar, Prasoon
    Sharma, Siddhartha
    Singh, Gagan Preet
    Srivastava, Amit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01): : 75 - 89
  • [42] A comparison of outcomes of locking versus non-locking plate fixation for the distal fibula fractures: a systematic review and meta-analysis
    Mandeep Singh Dhillon
    Rajesh Kumar Rajnish
    Prasoon Kumar
    Siddhartha Sharma
    Gagan Preet Singh
    Amit Srivastava
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 75 - 89
  • [43] Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly
    N. Schmelzer-Schmied
    P. Wieloch
    A. K. Martini
    W. Daecke
    International Orthopaedics, 2009, 33 : 773 - 778
  • [44] Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly
    Schmelzer-Schmied, N.
    Wieloch, P.
    Martini, A. K.
    Daecke, W.
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (03) : 773 - 778
  • [45] Locking versus non-locking plate fixation in the management of mandibular fractures: a meta-analysis
    Chrcanovic, B. R.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 43 (10) : 1243 - 1250
  • [46] Locking plates in distal humerus fractures: study of 43 patients
    Gupta, Rakesh Kumar
    Gupta, Vinay
    Marak, Dickey Richard
    CHINESE JOURNAL OF TRAUMATOLOGY, 2013, 16 (04) : 207 - 211
  • [47] Biomechanical Analysis of Volar and Dorsal Double Locking Plates for Fixation in Comminuted Extra-articular Distal Radius Fractures: A 3D Finite Element Study
    Lin, Yu-Hao
    Lin, Chun-Li
    Kuo, Hsien-Nan
    Sun, Ming-Tsung
    Chen, Alvin Chao-Yu
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 349 - 355
  • [48] Locking plates in distal humerus fractures:study of 43 patients
    Rakesh Kumar Gupta
    Vinay Gupta
    Dickey Richard Marak
    中华创伤杂志(英文版), 2013, (04) : 207 - 211
  • [49] Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
    Ramos Gloria, Jose Cristiano
    Fernandes, Ighor Andrade
    da Silveira, Esmeralda Maria
    de Souza, Glaciele Maria
    Rocha, Ricardo Lopes
    Galvao, Endi Lanza
    Moreira Falci, Saulo Gabriel
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2018, 22 (02) : 181 - 189
  • [50] Fixation of intra-articular fractures of the distal radius using intramedullary nailing: a randomized trial versus palmar locking plates
    Gradl, Gertraud
    Falk, Steffi
    Mittlmeier, Thomas
    Wendt, Martina
    Mielsch, Nadja
    Gradl, Georg
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S25 - S30