Locking versus non-locking plates in fixation of extra-articular distal humerus fracture: a randomized controlled study

被引:4
|
作者
Galal, Sherif [1 ,2 ]
Mattar, Yasser [1 ]
Solyman, Alaa Mohy Eldin [1 ]
Ezzat, Mostafa [1 ]
机构
[1] Cairo Univ, Fac Med, Dept Orthopaed Surg, Cairo 11559, Egypt
[2] Hosp Special Surg, Dept Orthopaed Surg, 535 E 70th St, New York, NY 10021 USA
关键词
Distal humerus; Fracture; Fixation; Locking plates; Randomized controlled; INTERNAL-FIXATION; INTERCONDYLAR FRACTURES; OPEN REDUCTION;
D O I
10.1007/s00264-020-04770-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Studies have shown that the use of nonlocking (reconstruction) plates in fixing distal humerus fractures may not yield stable fixation which therefore requires long immobilization and suboptimal functional results. There are reports showing that locking plates are biomechanically superior to nonlocking plates. The aim of this study was to compare elbow functional outcomes between locking and nonlocking plates in fixation of distal humerus fractures. Methods A single-centre, randomized control study was conducted at an academic level 1 trauma centre. A total of 60 patients with type 13-A fracture (AO/OTA classification) were randomized into two equal groups, locking plates group, and nonlocking plates group. The primary outcome measure was the Mayo elbow performance score (MEPS) at one year. Secondary outcomes measures were elbow flexion/extension arc, union, operative time, and complications (e.g., infection, heterotrophic ossification). Results The Mayo Elbow Performance Score (MEPS) at one year was 88 +/- 10.1 in locking plates group and 75.8 +/- 12.8 in nonlocking plates group. The difference was found to be statically significant (Pvalue = 0.01). Elbow flexion/extension arc of motion at one year was 116 degrees +/- 15 degrees in locking plates group and 113 degrees +/- 28 degrees in nonlocking plates. The difference was not found to be statistically significant (Pvalue = 0.17). Conclusion Both implants yield similar results, with locking plates showing slightly better clinical scores.
引用
收藏
页码:2761 / 2767
页数:7
相关论文
共 50 条
  • [31] A comparison of bone union and complication rates between locking and non-locking plates in distal fibular fracture: Retrospective study of 106 cases
    El Fatayri, Bachar
    Bulaid, Yassine
    Djebara, Az-Eddine
    Havet, Eric
    Mertl, Patrice
    Dehl, Massinissa
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (12): : 2324 - 2331
  • [32] Fatigue Failure in Extra-Articular Proximal Tibia Fractures: Locking Intramedullary Nail Versus Double Locking Plates-A Biomechanical Study
    Kandemir, Utku
    Herfat, Safa
    Herzog, Mary
    Viscogliosi, Paul
    Pekmezci, Murat
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (02) : E49 - E54
  • [33] Open reduction through original fracture line and fixation with locking plate is a feasible approach for extra-articular distal radius fracture malunion
    Bu, Guoyun
    Wei, Wanfu
    Li, Jian'an
    Yang, Tao
    Li, Mingxin
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (03): : 489 - 495
  • [34] Functional outcome of comminuted intra-articular and extra-articular distal femur fracture treated with Distal Femur Locking Plate
    Shah, Syed Ghulam Mujtaba
    Sahito, Badaruddin
    Kumar, Dileep
    Tariq, Syed Muhammad
    Parkh, Noman
    Ali, Maratib
    RAWAL MEDICAL JOURNAL, 2018, 43 (04): : 694 - 697
  • [35] Locking versus non-locking plating system in the treatment of mandibular fractures: A randomized comparative study
    Sarkar, Dibya Falgoon
    Mishra, Niranjan
    Samal, Dipti
    Pati, Debashish
    Kar, Indu Bhusan
    Mohapatra, Debjyoti
    Mishra, Abhipsa
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (03) : 184 - 190
  • [36] Volar Locking Plates Versus External Fixation and Adjuvant Pin Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study
    Williksen, John H.
    Frihagen, Frede
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Husby, Torstein
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (08): : 1469 - 1476
  • [37] What happens to the posterior comminution in extra-articular fractures of the distal radius treated with volar locking plates?
    Guillou, J.
    Darees, M.
    Pouges, C.
    Christiaens, N.
    Guerre, E.
    Chantelot, C.
    HAND SURGERY & REHABILITATION, 2019, 38 (02): : 91 - 96
  • [38] Treatment of extra-articular and simple articular distal radial fractures with intramedullary nail versus volar locking plate
    Safi, A.
    Hart, R.
    Teknedzjan, B.
    Kozak, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2013, 38 (07) : 774 - 779
  • [39] Non-locking plate fixation for AO type C3 fracture of the distal radius
    Dohi, Y.
    Omokawa, S.
    Fujitani, R.
    Yajima, H.
    PROCEEDINGS OF THE 10TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR SURGERY OF THE HAND & 7TH CONGRESS OF THE INTERNATIONAL FEDERATION OF SOCIETIES FOR HAND THERAPY, 2007, : 179 - +
  • [40] Infographic: Economic justification for intramedullary nail fixation over locking plate fixation for extra-articular distal tibial fractures
    Maredza, M.
    Petrou, S.
    Dritsaki, M.
    Achten, J.
    Griffin, J.
    Lamb, S. E.
    Parsons, N. R.
    Costa, M. L.
    BONE & JOINT JOURNAL, 2018, 100B (05): : 622 - 623