Locking versus non-locking plate fixation in the management of mandibular fractures: a meta-analysis

被引:8
|
作者
Chrcanovic, B. R. [1 ]
机构
[1] Malmo Univ, Dept Prosthodont, Fac Odontol, SE-20506 Malmo, Sweden
关键词
mandibular fracture; locking plate; non-locking plate; standard plate; complications; meta-analysis; BELO-HORIZONTE; FACIAL FRACTURES; 2.0-MM STANDARD; SYSTEM; STABILITY;
D O I
10.1016/j.ijom.2014.07.014
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present study was to test whether there is a significant difference in the clinical outcomes between locking and non-locking plate fixation in the management of mandibular fractures. An electronic search without time or language restrictions was undertaken in December 2013. Eligible studies were clinical human studies, either randomized or not. The search strategy identified 10 publications. The /2 statistic was used to express the percentage of the total variation across studies due to heterogeneity. The inverse variance method was used for the random-effects model in the case of heterogeneity being detected, or the fixed-effects model in the case of heterogeneity not being detected. The estimates of an intervention were expressed as the risk ratio (RR) with 95% confidence interval. Eight studies were judged to be at high risk of bias, whereas two studies were considered at moderate risk of bias. There was no statistically significant effect on the outcome of postoperative infection (P = 0.17), malocclusion (P = 0.15), hardware failure (P = 0.77), hardware removal (P = 0.95), wound dehiscence (P = 0.98), or paraesthesia (P = 0.20) in favour of locking plate fixation. The test for overall effect showed that the difference between the procedures did not significantly affect the incidence of postoperative complications (P = 0.21), with RR 0.79 (95% CI 0.54-1.14).
引用
收藏
页码:1243 / 1250
页数:8
相关论文
共 50 条
  • [1] A comparison of outcomes of locking versus non-locking plate fixation for the distal fibula fractures: a systematic review and meta-analysis
    Dhillon, Mandeep Singh
    Rajnish, Rajesh Kumar
    Kumar, Prasoon
    Sharma, Siddhartha
    Singh, Gagan Preet
    Srivastava, Amit
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2024, 34 (01): : 75 - 89
  • [2] A comparison of outcomes of locking versus non-locking plate fixation for the distal fibula fractures: a systematic review and meta-analysis
    Mandeep Singh Dhillon
    Rajesh Kumar Rajnish
    Prasoon Kumar
    Siddhartha Sharma
    Gagan Preet Singh
    Amit Srivastava
    European Journal of Orthopaedic Surgery & Traumatology, 2024, 34 : 75 - 89
  • [3] Complications of locking and non-locking plate systems in mandibular fractures
    Batbayar, E-O
    Dijkstra, P. U.
    Bos, R. R. M.
    van Minnen, B.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (09) : 1213 - 1226
  • [4] Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
    Ramos Gloria, Jose Cristiano
    Fernandes, Ighor Andrade
    da Silveira, Esmeralda Maria
    de Souza, Glaciele Maria
    Rocha, Ricardo Lopes
    Galvao, Endi Lanza
    Moreira Falci, Saulo Gabriel
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2018, 22 (02) : 181 - 189
  • [5] Three-dimensional versus standard miniplate, lag screws versus miniplates, locking plate versus non-locking miniplates: Management of mandibular fractures, a systematic review and meta-analysis
    Wusiman, Patiguli
    Taxifulati, Dilidaer
    Li Weidong
    Moming, Adili
    JOURNAL OF DENTAL SCIENCES, 2019, 14 (01) : 66 - 80
  • [6] Locking Plate System Versus Standard Plate Fixation in the Management of Mandibular Fractures: Meta-Analysis of Randomized Controlled Trials
    Wusiman, Patiguli
    Tuerxun, Julaiti
    Yaolidaxi, Buhiliqiemu
    Moming, Adili
    JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (06) : 1456 - 1461
  • [7] Locking plate versus non-locking plate in open-wedge high tibial osteotomy: a meta-analysis
    Jae Hwi Han
    Hyun Jung Kim
    Jae Gwang Song
    Jae Hyuk Yang
    Ryuichi Nakamura
    Daivesh Shah
    Young Jee Park
    Kyung Wook Nha
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 808 - 816
  • [8] Locking plate versus non-locking plate in open-wedge high tibial osteotomy: a meta-analysis
    Han, Jae Hwi
    Kim, Hyun Jung
    Song, Jae Gwang
    Yang, Jae Hyuk
    Nakamura, Ryuichi
    Shah, Daivesh
    Park, Young Jee
    Nha, Kyung Wook
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) : 808 - 816
  • [9] Locking versus non-locking plating system in the treatment of mandibular fractures: A randomized comparative study
    Sarkar, Dibya Falgoon
    Mishra, Niranjan
    Samal, Dipti
    Pati, Debashish
    Kar, Indu Bhusan
    Mohapatra, Debjyoti
    Mishra, Abhipsa
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2021, 49 (03) : 184 - 190
  • [10] Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis
    Gouk, Conor J. C.
    Bindra, Randip R.
    Tarrant, Drew J.
    Thomas, Michael J. E.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (09) : 954 - 960