Radiation dose vs. image quality for low-dose CT protocols of the head for maxillofacial surgery and oral implant planning

被引:46
|
作者
Loubele, M
Jacobs, R
Maes, F
Schutyser, F
Debaveye, D
Bogaerts, R
Coudyzer, W
Vandermeulen, D
van Cleynenbreugel, J
Marchal, G
Suetens, P
机构
[1] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Med Image Compt ESAT, PSI, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Oral Imaging Ctr, Sch Dent Oral Pathol & Maxillofacial Surg, B-3000 Louvain, Belgium
[3] Medicim NV, B-9100 St Niklaas, Belgium
[4] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Unit Person Dosemetry Radiat Protect, B-3000 Louvain, Belgium
[5] Katholieke Univ Leuven, Univ Hosp Gasthuisberg, Dept Radiol, B-3000 Louvain, Belgium
关键词
D O I
10.1093/rpd/nci749
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The goal of this study was to determine the acquisition parameters for a low-dose multi-slice CT protocol and to compare the effective dose and the image quality of this low-dose protocol with the image quality of a clinical multi-slice CT protocol, routinely used for visualisation of the head. The low-dose protocol was derived from a clinical multi-slice CT protocol by lowering mA s and kV and increasing the pitch. The low-dose protocol yielded a dose reduction from 1.5 to 0.18 mSv for a multi-slice CT scan of the whole head, whereas noise in the low-dose CT images was increased. For bone segmentation, noise could be reduced by use of a non-linear edge preserving smoothing filter. Tests on ESP and skull phantom indicated that the accuracy of the measurements on low-dose CT is acceptable for image-based planning of maxillofacial and oral implant surgery, reducing the dose by a factor of 8.
引用
收藏
页码:211 / 216
页数:6
相关论文
共 50 条
  • [1] Reduction of radiation dose in PET-CT: Low dose protocols and image quality
    Kim, Hyeon Sik
    Sheen, Heesoon
    Jung, Sung Pil
    Hong, Seon Pyo
    Byun, Byung-Hyun
    Min, Jung-Joon
    Lee, Byeong-il
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [2] Evaluation of Image Quality and Radiation Dose of Various Unenhanced Head CT Protocols
    Chen, L.
    Khan, M.
    Alapati, K.
    Hsieh, M.
    Barry, K.
    MEDICAL PHYSICS, 2015, 42 (06) : 3237 - 3237
  • [3] Influence of Low-Dose Protocols of CBCT on Dental Implant Planning
    de Castro, Hebert Sampaio
    Kehrwald, Ricardo
    Matheus, Ricardo Alves
    Gomes, Amanda Farias
    Queiroz, Polyane Mazucatto
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 307 - 312
  • [4] CT protocols: balancing radiation dose and image quality
    Richard Fotter
    Pediatric Radiology, 2011, 41 : 215 - 216
  • [5] CT protocols: balancing radiation dose and image quality
    Fotter, Richard
    PEDIATRIC RADIOLOGY, 2011, 41 : S215 - S216
  • [6] Low-dose CT angiography of the lower extremities: a comparison study of image quality and radiation dose
    Park, S.
    Park, S. H.
    Hwang, J. H.
    Kim, J. H.
    Lee, K. H.
    Shin, J. H.
    Pak, S. Y.
    Kang, J. M.
    CLINICAL RADIOLOGY, 2021, 76 (02) : 156.e19 - 156.e26
  • [7] Low-dose, volumetric helical CT - Image quality, radiation dose, and usefulness for evaluation of bronchiectasis
    Jung, KJ
    Lee, KS
    Kim, SY
    Kim, TS
    Pyeun, YS
    Lee, JY
    INVESTIGATIVE RADIOLOGY, 2000, 35 (09) : 557 - 563
  • [8] Radiation dose and image quality in head CT examinations
    Huda, W
    Chang, J
    Lieberman, KA
    Roskopf, ML
    RADIOLOGY, 2001, 221 : 160 - 160
  • [9] RADIATION DOSE AND IMAGE QUALITY IN PEDIATRIC HEAD CT
    Spampinato, Maria Vittoria
    Stalcup, Seth
    Matheus, Maria Gisele
    Byington, Kathleen
    Tyler, Michael
    Bickley, Stetson
    Tipnis, Sameer
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 310 - 316
  • [10] Comparison of image quality between conventional and low-dose nonenhanced head CT
    Mullins, ME
    Lev, MH
    Bove, P
    O'Reilly, CE
    Saini, S
    Rhea, JT
    Thrall, JH
    Hunter, GJ
    Hamberg, LM
    Gonzalez, G
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2004, 25 (04) : 533 - 538