Greenhouse Gas Emissions for Refrigerant Choices in Room Air Conditioner Units

被引:6
|
作者
Galka, Michael D. [1 ]
Lownsbury, James M. [1 ]
Blowers, Paul [1 ]
机构
[1] Univ Arizona, Dept Chem & Environm Engn, Tucson, AZ 85721 USA
关键词
PERFORMANCE; HCFC-22; ENERGY;
D O I
10.1021/es302338s
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO2-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a I ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.
引用
收藏
页码:12977 / 12985
页数:9
相关论文
共 50 条
  • [21] ROOM AIR CONDITIONER STORY . INTRODUCTION
    KOLB, PE
    ASHRAE JOURNAL, 1970, 12 (01): : 43 - &
  • [22] Canada to regulate greenhouse-gas, other air emissions
    不详
    OIL & GAS JOURNAL, 2007, 105 (19) : 34 - 35
  • [23] Local governance of greenhouse gas emissions from air travel
    Elofsson, Anna
    Smedby, Nora
    Larsson, Jorgen
    Naessen, Jonas
    JOURNAL OF ENVIRONMENTAL POLICY & PLANNING, 2018, 20 (05) : 578 - 594
  • [24] Fault detection for the reliability of the refrigerant inventory of the system air conditioner
    Tae, Sang-Jin
    Cho, Keumnam
    Kim, Hoon Mo
    SAFETY AND STRUCTURAL INTEGRITY 2006, 2007, 120 : 169 - +
  • [25] Optimization study on the structure and the flow of a refrigerant distributor for air conditioner
    Zhang, Derun
    Pu, Liang
    Nian, Luozhu
    Meng, Zhongyi
    Gu, Tangtang
    Liu, Min
    Zhou, Yachen
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 131 (131) : 847 - 856
  • [26] Optimal Refrigerant by Integrated Operational and Environmental Criteria in Air Conditioner
    Mutlag, Sattar A.
    Dawood, H. K.
    12TH INTERNATIONAL CONFERENCE ON THE DEVELOPMENTS IN ESYSTEMS ENGINEERING (DESE 2019), 2019, : 309 - 314
  • [27] Comprehensive analysis of refrigerant R134a: Implications for estimating and managing greenhouse gas emissions
    Kim, Sang Woo
    Park, Miyeon
    Trisna, Beni Adi
    Lee, Jeongsoon
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 158 : 135 - 143
  • [28] Greenhouse gas emissions
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2004, 83 (11): : 9 - 9
  • [29] Experimental research on the explosion characteristics in the indoor and outdoor units of a split air conditioner using the R290 refrigerant
    Zhang, Wang
    Yang, Zhao
    Zhang, Xin
    Lv, Dong
    Jiang, Nan
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 408 - 417
  • [30] Reduce air emissions from natural gas vaporization units
    Rosetta, M. J.
    Price, B. C.
    Hollenbach, R. J.
    HYDROCARBON PROCESSING, 2009, 88 (01): : 51 - 54