Greenhouse Gas Emissions for Refrigerant Choices in Room Air Conditioner Units

被引:6
|
作者
Galka, Michael D. [1 ]
Lownsbury, James M. [1 ]
Blowers, Paul [1 ]
机构
[1] Univ Arizona, Dept Chem & Environm Engn, Tucson, AZ 85721 USA
关键词
PERFORMANCE; HCFC-22; ENERGY;
D O I
10.1021/es302338s
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this work, potential replacement refrigerants for window-mounted room air conditioners (RACs) in the U.S. have been evaluated using a greenhouse gas (GHG) emissions analysis. CO2-equivalent emissions for several hydrofluoroethers (HFEs) and other potential replacements were compared to the most widely used refrigerants today. Included in this comparison are pure refrigerants that make up a number of hydrofluorocarbon (HFC) mixtures, pure hydrocarbons, and historically used refrigerants such as propane and ammonia. GHG emissions from direct and indirect sources were considered in this thermodynamic analysis. Propylene, dimethyl ether, ammonia, R-152a, propane, and HFE-152a all performed effectively in a I ton window unit and produced slightly lower emissions than the currently used R-22 and R-134a. The results suggest that regulation of HFCs in this application would have some effect on reducing emissions since end-of-life emissions remain at 55% of total refrigerant charge despite EPA regulations that mandate 80% recovery. Even so, offsite emissions due to energy generation dominate over direct GHG emissions and all the refrigerants perform similarly in totals of indirect GHG emissions.
引用
收藏
页码:12977 / 12985
页数:9
相关论文
共 50 条
  • [31] Characteristics of room air conditioner with two-stage compression and gas injection cycle
    Mechanical Engineering Research Lab., 832-2 Horìguchi, Hitachinaka-shi, Ibaraki, 312-0034, Japan
    Nihon Kikai Gakkai Ronbunshu, B, 2009, 753 (1157-1167):
  • [32] ROOM AIR-CONDITIONER FOR TROPICAL USE
    WATANABE, O
    TAJIMA, M
    NIGO, T
    TOSHIBA REVIEW, 1979, (119): : 31 - 34
  • [33] Research on a compact adsorption room air conditioner
    Yang, G. Z.
    Xia, Z. Z.
    Wang, R. Z.
    Keletigui, Daou
    Wang, D. C.
    Dong, Z. H.
    Yang, X.
    ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (15-16) : 2167 - 2177
  • [34] Greenhouse gas and air pollutant emissions from power barges (powerships)
    Marais, Eloise A.
    Akker, Orianna
    Wiedinmyer, Christine
    ENVIRONMENTAL SCIENCE-ADVANCES, 2022, 1 (02): : 164 - 169
  • [35] ROOM AIR CONDITIONER DESIGN PARAMETERS - PERFORMANCE
    METCALFE, FS
    ASHRAE JOURNAL, 1970, 12 (01): : 43 - &
  • [36] Humidity's impact on greenhouse gas emissions from air conditioning
    Woods, Jason
    James, Nelson
    Kozubal, Eric
    Bonnema, Eric
    Brief, Kristin
    Voeller, Liz
    Rivest, Jessy
    JOULE, 2022, 6 (04) : 726 - 741
  • [37] The Role of Direct Air Capture in Mitigation of Anthropogenic Greenhouse Gas Emissions
    Beuttler, Christoph
    Charles, Louise
    Wurzbacher, Jan
    FRONTIERS IN CLIMATE, 2019, 1
  • [38] Countermeasures against air pollution and greenhouse gas emissions in Shanxi Province
    Sorstrom, SE
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 1999, 12 (01) : 42 - 50
  • [39] STUDY OF FACTORS INFLUENCING NON-UNIFORM GAS-LIQUID DISTRIBUTION IN THE REFRIGERANT DISTRIBUTOR IN AN AIR CONDITIONER
    Ishii, Eiji
    Yoshimura, Kazuki
    ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1C: SYMPOSIA, 2014,
  • [40] Refrigerant migration during startup of a split air conditioner in heating mode
    Han, Binglong
    Yan, Gang
    Yu, Jianlin
    APPLIED THERMAL ENGINEERING, 2019, 148 : 1068 - 1073