Fault detection for the reliability of the refrigerant inventory of the system air conditioner

被引:0
|
作者
Tae, Sang-Jin [1 ]
Cho, Keumnam [2 ]
Kim, Hoon Mo
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 440746, South Korea
[2] Sungkyunkwan Univ, Sch Mech Engn, Suwon, South Korea
来源
关键词
charged refrigerant amount; system air-conditioner; fuzzy algorithm;
D O I
10.4028/www.scientific.net/SSP.120.169
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in system air-conditioner than in a general single air-conditioner. Experiments were performed for 6 HP outdoor units with 3 indoor units in a psychrometric calorimeter. The experimental amount of charged refrigerant was ranged from 60% to 140% with 10% increase. Fuzzy algorithm was employed for detecting the charged refrigerant amount in a system air-conditioner. The experimental data were used for curve fitting for general ranges for indoor and outdoor temperature conditions. Membership function were determined for whole ranges of experimentally measured data and rule-base were defined for each amount of refrigerant charge. Developed program successfully predicted the measured data within 10% resolution range.
引用
收藏
页码:169 / +
页数:3
相关论文
共 50 条
  • [1] Fault detection for the refrigerant inventory of the system air conditioner
    Tae, Sang-Jin
    Cho, Keumnam
    Youn, Back
    Moon, Je-Myung
    Kim, Jong-Yup
    Kwon, Hyung-Jin
    PROCEEDINGS OF THE 3RD ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING VOLS I AND II, 2006, : 35 - +
  • [2] Fault Detection for Air Conditioner using PCANet
    Yang, Hailong
    Yang, Zuyuan
    Yang, Hao
    Xie, Yuhui
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 3363 - 3366
  • [3] Reliability evaluation of scroll compressor for system air conditioner
    Chang, Mu-Seong
    Park, Jong-Won
    Choi, Young-Min
    Park, Tae-Kook
    Choi, Byung-Oh
    Shin, Chang-Joo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (10) : 4459 - 4463
  • [4] Reliability evaluation of scroll compressor for system air conditioner
    Mu-Seong Chang
    Jong-Won Park
    Young-Min Choi
    Tae-Kook Park
    Byung-Oh Choi
    Chang-Joo Shin
    Journal of Mechanical Science and Technology, 2016, 30 : 4459 - 4463
  • [5] MODELING OF A SOLAR-OPERATED ABSORPTION AIR CONDITIONER SYSTEM WITH REFRIGERANT STORAGE
    GRASSIE, SL
    SHERIDAN, NR
    SOLAR ENERGY, 1977, 19 (06) : 691 - 700
  • [6] Refrigerant leakage detection in an EEV installed residential air conditioner with limited sensor installations
    Yoo, Jin Woo
    Bin Hong, Sung
    Kim, Min Soo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 78 : 157 - 165
  • [7] Performance Evaluation and Optimization of A Refrigerant Distributor for Air Conditioner
    Yoshioka, Shun
    Kim, Hyunyoung
    Kasai, Kazushige
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2008, 3 (01): : 68 - 77
  • [8] Air Conditioner Refrigerant Inhalation: A Habit with Chilling Consequences
    Caplan, Jason P.
    Pope, Amanda E.
    Boric, Christy A.
    Benford, Dawn A.
    PSYCHOSOMATICS, 2012, 53 (03) : 273 - 276
  • [9] ExPeriniental research on a hydrocarbon refrigerant used in air conditioner
    Wang, H. D.
    Cai, Z. M.
    Cheng, R. D.
    CRYOGENICS AND REFRIGERATION, PROCEEDINGS, 2008, : 864 - 868
  • [10] Performance evaluation and optimization of a refrigerant distributor for air conditioner
    Yoshioka, Shun
    Kim, Hyunyoung
    Kasai, Kazushige
    PROCEEDINGS OF THE ASME/JSME THERMAL ENGINEERING SUMMER HEAT TRANSFER CONFERENCE 2007, VOL 2, 2007, : 603 - 609