Fault detection for the reliability of the refrigerant inventory of the system air conditioner

被引:0
|
作者
Tae, Sang-Jin [1 ]
Cho, Keumnam [2 ]
Kim, Hoon Mo
机构
[1] Sungkyunkwan Univ, Grad Sch, Suwon 440746, South Korea
[2] Sungkyunkwan Univ, Sch Mech Engn, Suwon, South Korea
来源
关键词
charged refrigerant amount; system air-conditioner; fuzzy algorithm;
D O I
10.4028/www.scientific.net/SSP.120.169
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study developed a program for detecting charged refrigerant amount in system air-conditioner. System air-conditioner is an air-conditioning system with multiple indoor units. Due to the complexity of the system, it is more difficult to detect the refrigerant amount charged in system air-conditioner than in a general single air-conditioner. Experiments were performed for 6 HP outdoor units with 3 indoor units in a psychrometric calorimeter. The experimental amount of charged refrigerant was ranged from 60% to 140% with 10% increase. Fuzzy algorithm was employed for detecting the charged refrigerant amount in a system air-conditioner. The experimental data were used for curve fitting for general ranges for indoor and outdoor temperature conditions. Membership function were determined for whole ranges of experimentally measured data and rule-base were defined for each amount of refrigerant charge. Developed program successfully predicted the measured data within 10% resolution range.
引用
收藏
页码:169 / +
页数:3
相关论文
共 50 条
  • [41] Area detection technology for Air Conditioner
    Komatsu, Yuto
    Hamada, Koichi
    Nukaga, Nobuo
    Kagehiro, Tatsuhiko
    Ueda, Yoshiro
    Matsubara, Eisuke
    Jinno, Noriyuki
    2015 54TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2015, : 1094 - 1100
  • [42] Study on fault identification rules for real refrigerant leakage in R290 room air conditioner based random forest algorithm
    Yang, Jie
    Wu, Jianghong
    Yu, Xinyu
    Liang, Yongbiao
    EXPERT SYSTEMS WITH APPLICATIONS, 2024, 238
  • [43] Case study of fault detection and diagnosis of a household air conditioner with a dynamic refrigeration cycle simulator
    Seo, Jung Ah
    Lim, Tae Hoon
    Shin, Younggy
    Lee, Seung Hyeon
    Kim, Sanghun
    APPLIED THERMAL ENGINEERING, 2016, 94 : 198 - 208
  • [44] Study on the impacts of refrigerant leakage on the performance and reliability of datacenter composite air conditioning system
    Zhang, Yiqi
    Li, Mengyi
    Dong, Jiaxiang
    Zhang, Ce
    Li, Xiuming
    Han, Zongwei
    ENERGY, 2023, 284
  • [45] Refrigerant charge fault detection method of air source heat pump system using convolutional neural network for energy saving
    Eom, Yong Hwan
    Yoo, Jin Woo
    Hong, Sung Bin
    Kim, Min Soo
    ENERGY, 2019, 187
  • [46] Air data system fault modeling and detection
    Freeman, Paul
    Seiler, Peter
    Balas, Gary J.
    CONTROL ENGINEERING PRACTICE, 2013, 21 (10) : 1290 - 1301
  • [47] Real Time Object Detection for Sustainable Air Conditioner Energy Management System
    Ying, Chang Shi
    PuiLin, C.
    INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2024, 15 (10) : 129 - 138
  • [48] Measurement of refrigerant mass distribution within a R290 split air conditioner
    Li, Tingxun
    Lu, Jian
    Chen, Lei
    He, Dongcai
    Qiu, Xiaozhou
    Li, Hongyao
    Liu, Zhen
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 57 : 163 - 172
  • [49] The Impact of Hydrocarbon R290 Refrigerant on Air Conditioner Performance and Environmental Sustainability
    Khai, Ferdinand Ng Siek
    Zakaria, Nurul Sabihah
    PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY, 2025, 33 (02): : 1069 - 1087
  • [50] AN EXPERIMENTAL ANALYSIS OF THE EFFECT OF REFRIGERANT CHARGE LEVEL AND OUTDOOR CONDITION ON A WINDOW AIR CONDITIONER
    Raj, M. Herbert
    Lal, D. Mohan
    THERMAL SCIENCE, 2010, 14 (04): : 1121 - 1138