Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo

被引:15
|
作者
Cervantes, Barbara [1 ]
Van, Anh T. [2 ]
Weidlich, Dominik [1 ]
Kooijman, Hendrick [3 ]
Hock, Andreas [3 ]
Rummeny, Ernst J. [1 ]
Gersing, Alexandra [1 ]
Kirschke, Jan S. [4 ]
Karampinos, Dimitrios C. [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Inst Med Engn IMETUM, Garching, Germany
[3] Philips Healthcare, Hamburg, Germany
[4] Tech Univ Munich, Dept Diagnost & Intervent Neuroradiol, Klinikum Rechts Isar, Munich, Germany
基金
欧洲研究理事会;
关键词
magnetic resonance neurography; peripheral nerves MRI; diffusion prepared turbo spin echo; motion-induced phase errors; body diffusion; lumbar plexus; MAGNETIC-RESONANCE NEUROGRAPHY; MR NEUROGRAPHY; PERIPHERAL-NERVES; PROPELLER MRI; FLIP ANGLES; PLEXUS; T-2; POLYNEUROPATHY; FEASIBILITY; MOTION;
D O I
10.1002/mrm.27072
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo perform in vivo isotropic-resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase-navigated diffusion-prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase-error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. MethodsPhase-navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy-current effects on the signal magnitude. Phase navigation of motion-induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single-shot echo planar imaging (ss-EPI) in 13 subjects. Diffusion data were phase-corrected per k(z) plane with respect to T-2-weighted data. The effects of motion-induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss-EPI. ResultsNon-phase-corrected 3D TSE resulted in artifacts in diffusion-weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD]=2.060.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD=1.73 +/- 0.26) of statistical significance (P0.001) and in closer agreement with ss-EPI DTI parameters (MD=1.62 +/- 0.21). ConclusionDP 3D TSE with phase correction allows distortion-free isotropic diffusion imaging of lower back nerves with robustness to motion-induced artifacts and DTI quantification errors. Magn Reson Med 80:609-618, 2018. (c) 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
引用
收藏
页码:609 / 618
页数:10
相关论文
共 50 条
  • [1] Analysis of phase error effects in multishot diffusion-prepared turbo spin echo imaging
    Van, Anh T.
    Cervantes, Barbara
    Kooijman, Hendrik
    Karampinos, Dimitrios C.
    [J]. QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2017, 7 (02) : 238 - 250
  • [2] Diffusion-Weighted Imaging of the Macaque Brain Using Diffusion-Prepared Turbo Spin Echo in MRI
    Zhang, Jialu
    Zhang, Xiaotong
    [J]. APPLIED SCIENCES-BASEL, 2021, 11 (24):
  • [3] 3D diffusion tensor imaging with 2D navigated turbo spin echo
    von Mengershausen, M
    Norris, DG
    Driesel, W
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (04) : 206 - 216
  • [4] 3D diffusion tensor imaging with 2D navigated turbo spin echo
    M. von Mengershausen
    D. G. Norris
    W. Driesel
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 206 - 216
  • [5] High-resolution diffusion imaging using phase-corrected segmented echo-planar imaging
    Brockstedt, S
    Moore, JR
    Thomsen, C
    Holtås, S
    Ståhlberg, F
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 649 - 657
  • [6] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Zhang, Qinwei
    van Houdt, Petra J.
    Lambregts, Doenja M. J.
    van Triest, Baukelien
    Kop, Marnix P. M.
    Coolen, Bram F.
    Strijkers, Gustav J.
    van der Heide, Uulke A.
    Nederveen, Aart J.
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [7] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Qinwei Zhang
    Petra J. van Houdt
    Doenja M. J. Lambregts
    Baukelien van Triest
    Marnix P. M. Kop
    Bram F. Coolen
    Gustav J. Strijkers
    Uulke A. van der Heide
    Aart J. Nederveen
    [J]. European Radiology Experimental, 4
  • [8] Diffusion-prepared 3D gradient spin-echo sequence for improved oscillating gradient diffusion MRI
    Wu, Dan
    Liu, Dapeng
    Hsu, Yi-Cheng
    Li, Haotian
    Sun, Yi
    Qin, Qin
    Zhang, Yi
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (01) : 92 - 102
  • [9] 3D isotropic resolution diffusion-prepared magnitude-stabilized bSSFP imaging with high geometric fidelity at 1.5 Tesla
    Gao Yu
    Zhou Ziwu
    Han Fei
    Zhong Xiaodong
    Yang Yingli
    Hu Peng
    [J]. MEDICAL PHYSICS, 2020, 47 (08) : 3511 - 3519
  • [10] High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo
    Sollmann, Nico
    Weidlich, Dominik
    Cervantes, Barbara
    Klupp, Elisabeth
    Ganter, Carl
    Kooijman, Hendrik
    Rummeny, Ernst J.
    Zimmer, Claus
    Kirschke, Jan S.
    Karampinos, Dimitrios C.
    [J]. CLINICAL NEURORADIOLOGY, 2019, 29 (02) : 223 - 230