Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo

被引:15
|
作者
Cervantes, Barbara [1 ]
Van, Anh T. [2 ]
Weidlich, Dominik [1 ]
Kooijman, Hendrick [3 ]
Hock, Andreas [3 ]
Rummeny, Ernst J. [1 ]
Gersing, Alexandra [1 ]
Kirschke, Jan S. [4 ]
Karampinos, Dimitrios C. [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Radiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Tech Univ Munich, Inst Med Engn IMETUM, Garching, Germany
[3] Philips Healthcare, Hamburg, Germany
[4] Tech Univ Munich, Dept Diagnost & Intervent Neuroradiol, Klinikum Rechts Isar, Munich, Germany
基金
欧洲研究理事会;
关键词
magnetic resonance neurography; peripheral nerves MRI; diffusion prepared turbo spin echo; motion-induced phase errors; body diffusion; lumbar plexus; MAGNETIC-RESONANCE NEUROGRAPHY; MR NEUROGRAPHY; PERIPHERAL-NERVES; PROPELLER MRI; FLIP ANGLES; PLEXUS; T-2; POLYNEUROPATHY; FEASIBILITY; MOTION;
D O I
10.1002/mrm.27072
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo perform in vivo isotropic-resolution diffusion tensor imaging (DTI) of lumbosacral and sciatic nerves with a phase-navigated diffusion-prepared (DP) 3D turbo spin echo (TSE) acquisition and modified reconstruction incorporating intershot phase-error correction and to investigate the improvement on image quality and diffusion quantification with the proposed phase correction. MethodsPhase-navigated DP 3D TSE included magnitude stabilizers to minimize motion and eddy-current effects on the signal magnitude. Phase navigation of motion-induced phase errors was introduced before readout in 3D TSE. DTI of lower back nerves was performed in vivo using 3D TSE and single-shot echo planar imaging (ss-EPI) in 13 subjects. Diffusion data were phase-corrected per k(z) plane with respect to T-2-weighted data. The effects of motion-induced phase errors on DTI quantification was assessed for 3D TSE and compared with ss-EPI. ResultsNon-phase-corrected 3D TSE resulted in artifacts in diffusion-weighted images and overestimated DTI parameters in the sciatic nerve (mean diffusivity [MD]=2.060.45). Phase correction of 3D TSE DTI data resulted in reductions in all DTI parameters (MD=1.73 +/- 0.26) of statistical significance (P0.001) and in closer agreement with ss-EPI DTI parameters (MD=1.62 +/- 0.21). ConclusionDP 3D TSE with phase correction allows distortion-free isotropic diffusion imaging of lower back nerves with robustness to motion-induced artifacts and DTI quantification errors. Magn Reson Med 80:609-618, 2018. (c) 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
引用
收藏
页码:609 / 618
页数:10
相关论文
共 50 条
  • [41] High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
    Chengcheng Zhu
    Henrik Haraldsson
    Bing Tian
    Karl Meisel
    Nerissa Ko
    Michael Lawton
    John Grinstead
    Sinyeob Ahn
    Gerhard Laub
    Christopher Hess
    David Saloner
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 559 - 570
  • [42] High resolution imaging of the intracranial vessel wall at 3 and 7 T using 3D fast spin echo MRI
    Zhu, Chengcheng
    Haraldsson, Henrik
    Tian, Bing
    Meisel, Karl
    Ko, Nerissa
    Lawton, Michael
    Grinstead, John
    Ahn, Sinyeob
    Laub, Gerhard
    Hess, Christopher
    Saloner, David
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (03) : 559 - 570
  • [43] Self-calibrating wave-encoded 3D turbo spin echo imaging using subspace model based autofocusing
    Zhou, Zechen
    Yuan, Chun
    Boernert, Peter
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1250 - 1262
  • [44] Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin-echo sequences
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Sakata, Noriyuki
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E304 - E309
  • [45] Regional characteristics of newly diagnosed grade 3 brain gliomas using MRI, 3D MR spectroscopic imaging, and diffusion tensor imaging
    Isik, Esin Ozturk
    Pirzkall, Andrea
    Chang, Susan M.
    Nelson, Sarah J.
    [J]. NEURO-ONCOLOGY, 2006, 8 (04) : 493 - 494
  • [46] 3D reconstruction and fiber quantification in the pig lower esophageal sphincter region using in vitro diffusion tensor imaging
    Liao, Donghua
    Gregersen, Hans
    Agger, Peter
    Laustsen, Christoffer
    Ringgaard, Steffen
    Stodkilde-Jorgensen, Hans
    Zhao, Jingbo
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2018, 4 (02):
  • [47] IN VIVO 3D REPRESENTATION OF THE LEVATOR ANI MUSCLE USING DIFFUSION TENSOR IMAGING WITH FIBER TRACTOGRAPHY: INITIAL RESULTS
    Rousset, P.
    Deux, J. F.
    Buy, J. N.
    Deval, B.
    Rahmouni, A.
    Vadrot, D.
    Delmas, V
    [J]. NEUROUROLOGY AND URODYNAMICS, 2011, 30 (06) : 1113 - 1114
  • [48] High-Resolution 3D in vivo Brain Diffusion Tensor Imaging at Ultrahigh Fields: Following Maturation on Juvenile and Adult Mice
    Yon, Maxime
    Bao, Qingjia
    Chitrit, Odelia Jacqueline
    Henriques, Rafael Neto
    Shemesh, Noam
    Frydman, Lucio
    [J]. FRONTIERS IN NEUROSCIENCE, 2020, 14
  • [49] High-resolution DTI of a localized volume using 3D single-shot Diffusion-Weighted STimulated Echo-Planar Imaging (3D ss-DWSTEPI)
    Jeong, Eun-Kee
    Kim, Seong-Eun
    Kholmovski, Eugene G.
    Parker, Dennis L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1173 - 1181
  • [50] 3D turbo field echo with diffusion-sensitized driven-equilibrium preparation technique (DSDE-TFE) versus echo planar imaging in evaluation of diffusivity of retinoblastoma
    Hiwatashi, Aki
    Togao, Osamu
    Yamashita, Koji
    Kikuchi, Kazufumi
    Yoshikawa, Hiroshi
    Obara, Makoto
    Honda, Hiroshi
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1067):