3D diffusion tensor imaging with 2D navigated turbo spin echo

被引:2
|
作者
von Mengershausen, M
Norris, DG
Driesel, W
机构
[1] Max Planck Inst Human Cognit & Brain Sci, D-04103 Leipzig, Germany
[2] FC Donders Ctr Cognit Neuroimaging, NL-6500 HB Nijmegen, Netherlands
关键词
3D DTI; 2D navigator; motion correction; Eddy-current compensation; high resolution; isotropic voxels;
D O I
10.1007/s10334-005-0118-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A Cartesian two-dimensional navigator with variable orientation for online motion correction is introduced. It corrects for all possible zeroth- and first-order phase errors due to rigid-body motion of a subject during the diffusion-weighting preparation. The technique is developed for the application of three-dimensional (3D) imaging sequences, which offer the opportunity of high-resolution diffusion-weighted imaging, or diffusion tensor imaging (DTI) with isotropic voxel resolution. The navigator was applied to a displaced 3D turbo spin-echo sequence with an ECG-gated diffusion preparation to avoid phase errors due to gross brain pulsation. Online and offline corrected in vivo images acquired with this sequence are compared to investigate the advantages of online correction. Also eigenvector maps of the diffusion tensor are presented with an isotropic resolution of 1 mm(3), which indicate that this new navigator technique is a promising approach for high-resolution DTI.
引用
收藏
页码:206 / 216
页数:11
相关论文
共 50 条
  • [1] 3D diffusion tensor imaging with 2D navigated turbo spin echo
    M. von Mengershausen
    D. G. Norris
    W. Driesel
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 206 - 216
  • [2] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Zhang, Qinwei
    van Houdt, Petra J.
    Lambregts, Doenja M. J.
    van Triest, Baukelien
    Kop, Marnix P. M.
    Coolen, Bram F.
    Strijkers, Gustav J.
    van der Heide, Uulke A.
    Nederveen, Aart J.
    [J]. EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [3] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Qinwei Zhang
    Petra J. van Houdt
    Doenja M. J. Lambregts
    Baukelien van Triest
    Marnix P. M. Kop
    Bram F. Coolen
    Gustav J. Strijkers
    Uulke A. van der Heide
    Aart J. Nederveen
    [J]. European Radiology Experimental, 4
  • [4] Qualitative and quantitative assessment of wrist MRI at 3.0T: comparison between isotropic 3D turbo spin echo and isotropic 3D fast field echo and 2D turbo spin echo
    Jung, Jee Young
    Yoon, Young Cheol
    Jung, Jin Young
    Choe, Bong-Keun
    [J]. ACTA RADIOLOGICA, 2013, 54 (03) : 284 - 291
  • [5] Improving the robustness of 3D turbo spin echo imaging to involuntary motion
    Li, Guobin
    Zaitsev, Maxim
    Buechert, Martin
    Raithel, Esther
    Paul, Dominik
    Korvink, Jan G.
    Hennig, Juergen
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (04) : 329 - 345
  • [6] Improving the robustness of 3D turbo spin echo imaging to involuntary motion
    Guobin Li
    Maxim Zaitsev
    Martin Büchert
    Esther Raithel
    Dominik Paul
    Jan G. Korvink
    Jürgen Hennig
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 329 - 345
  • [7] Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo
    Cervantes, Barbara
    Van, Anh T.
    Weidlich, Dominik
    Kooijman, Hendrick
    Hock, Andreas
    Rummeny, Ernst J.
    Gersing, Alexandra
    Kirschke, Jan S.
    Karampinos, Dimitrios C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 609 - 618
  • [8] SPIN DIFFUSION IN 2D AND 3D QUANTUM SOLIDS
    COWAN, B
    MULLIN, WJ
    NELSON, E
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 1989, 77 (3-4) : 181 - 193
  • [9] A 2D spiral turbo-spin-echo technique
    Li, Zhiqiang
    Karis, John P.
    Pipe, James G.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (05) : 1989 - 1996
  • [10] Magnetic resonance imaging of the cervical spine: comparison of 2D T2-weighted turbo spin echo, 2D T2*weighted gradient-recalled echo and 3D T2-weighted variable flip-angle turbo spin echo sequences
    Meindl, T.
    Wirth, S.
    Weckbach, S.
    Dietrich, O.
    Reiser, M.
    Schoenberg, S. O.
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (03) : 713 - 721