3D isotropic resolution diffusion-prepared magnitude-stabilized bSSFP imaging with high geometric fidelity at 1.5 Tesla

被引:3
|
作者
Gao Yu [1 ,2 ]
Zhou Ziwu [1 ]
Han Fei [1 ]
Zhong Xiaodong [3 ]
Yang Yingli [2 ,4 ]
Hu Peng [1 ,2 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90024 USA
[2] Univ Calif Los Angeles, Phys & Biol Med IDP, Los Angeles, CA 90095 USA
[3] Siemens Healthcare, MR R&D Collaborat, Los Angeles, CA USA
[4] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90024 USA
关键词
distortion-free diffusion; magnitude stabilizer; 3D diffusion; READOUT-SEGMENTED EPI; TREATMENT RESPONSE; PROSTATE-CANCER; INTERLEAVED EPI; WEIGHTED MRI; BRAIN; MAP; RECONSTRUCTION; RADIOTHERAPY; FEASIBILITY;
D O I
10.1002/mp.14195
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction MRI has been increasingly used in radiation therapy to facilitate tumor and organ delineation and assess treatment response. Diffusion MRI can provide cellularity information and may enable functional-based treatment planning and adaptation. However, strong distortion associated with the conventional diffusion-weighted single-shot echo-planar imaging (DW-ssEPI) sequence is problematic for accurate target delineation. The goal of this work is to propose a 3D diffusion sequence with minimal distortion for radiation therapy applications. Methods A 3D diffusion-prepared magnitude-stabilized balanced steady-state free precession sequence (DP-MS-bSSFP) was developed. A 2D navigator was acquired during the linear catalyzation stage of the bSSFP readout to estimate the phase, which was then used in a plane-by-plane low-rank constrained reconstruction to correct the shot-to-shot k-space inconsistency. A diffusion phantom was scanned to evaluate and compare the geometric reliability and apparent diffusion coefficient (ADC) accuracy with the conventional DW-ssEPI. Eight landmarks were selected on each slice of the images to calculate the target registration error (TRE), which was used as a surrogate for geometric fidelity. The phantom was scanned under both 0celcius and room temperature. Brain scans were performed on five healthy volunteers. In the first volunteer, protocols of 1, 2, and 4 shots per Kz plane were compared. In vivo geometric fidelity and ADC accuracy were evaluated on the remaining four volunteers using the protocol of four shots per Kz plane. In the geometric fidelity study, 8-10 landmarks were picked on each slice to calculate the TRE. Regions of interest were placed on the white matter, the cerebellum, and the cerebrospinal fluid region to evaluate the ADC agreement between DW-ssEPI and DP-MS using the Bland-Altman plot. All scans were performed at 1.5 mm isotropic resolution to meet the high-resolution requirement of many radiotherapy applications. Results The DP-MS had drastically improved geometric accuracy compared with DW-ssEPI on the phantom. The mean TRE decreased from 2.09 mm to 0.70 mm. The percentage difference of the ADC values between the two diffusion sequences were less than 5.5% and 7% for the 0celcius and room temperature study, respectively. The DW-ssEPI had strong distortion and susceptibility-related artifacts at tissue air boundary, whereas distortion was minimal in DP-MS images. Overall, the mean/max TRE was over 2 mm/7 mm in the volunteers for DW-ssEPI, whereas less than 0.8 mm/2 mm for DP-MS. Good ADC agreement was observed for the white matter, the cerebellum, and the CSF based on the Bland-Altman plots. Conclusion A 3D diffusion sequence was developed and validated. It provided high-resolution diffusion imaging with mean distortion less than 1 mm at 1.5 T, and is a promising imaging technique for treatment planning and adaptive radiotherapy.
引用
收藏
页码:3511 / 3519
页数:9
相关论文
共 50 条
  • [1] Multishot diffusion-prepared magnitude-stabilized balanced steady-state free precession sequence for distortion-free diffusion imaging
    Gao, Yu
    Han, Fei
    Zhou, Ziwu
    Zhong, Xiaodong
    Bi, Xiaoming
    Neylon, John
    Santhanam, Anand
    Yang, Yingli
    Hu, Peng
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2374 - 2384
  • [2] Diffusion-Prepared Multi-Shot BSSFP Imaging with Gradient Stabilizer for High-Resolution and Distortion-Free Diffusion Imaging
    Gao, Y.
    Han, F.
    Zhou, Z.
    Zhong, X.
    Neylon, J.
    Santhanam, A.
    Yang, Y.
    Hu, P.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E391 - E391
  • [3] Isotropic resolution diffusion tensor imaging of lumbosacral and sciatic nerves using a phase-corrected diffusion-prepared 3D turbo spin echo
    Cervantes, Barbara
    Van, Anh T.
    Weidlich, Dominik
    Kooijman, Hendrick
    Hock, Andreas
    Rummeny, Ernst J.
    Gersing, Alexandra
    Kirschke, Jan S.
    Karampinos, Dimitrios C.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 609 - 618
  • [4] High-resolution isotropic 3D diffusion tensor Imaging of the human brain
    Golay, X
    Jiang, H
    van Zijl, PCM
    Mori, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (05) : 837 - 843
  • [5] In vivo 3D high resolution cardiac diffusion weighted MRI: a motion compensated diffusion-prepared balanced steady-state free precession approach
    Christopher T Nguyen
    Zhaoyang Fan
    Behzad Sharif
    Yi He
    Rohan Dharmakumar
    Daniel S Berman
    Debiao Li
    [J]. Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [6] High-Resolution Magnetization-Prepared 3D-FLAIR Imaging at 7.0 Tesla
    Visser, Fredy
    Zwanenburg, Jaco J. M.
    Hoogduin, Johannes M.
    Luijten, Peter R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 194 - 202
  • [7] Distortion-free 3D diffusion imaging of the prostate using a multishot diffusion-prepared phase-cycled acquisition and dictionary matching
    Roccia, Elisa
    Neji, Radhouene
    Benkert, Thomas
    Kiefer, Berthold
    Goh, Vicky
    Dregely, Isabel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1441 - 1454
  • [8] Improved high-resolution pediatric vascular imaging with Gadofosveset-Enhanced 3d respiratory navigated IR GRE imaging compared to 3D bSSFP imaging
    Animesh Tandon
    James W Parks
    Sassan Hashemi
    Denver Sallee
    Tim Slesnick
    [J]. Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [9] HIGH-RESOLUTION 3D CRANIOCERVICAL HELICAL CT - IS ISOTROPIC IMAGING POSSIBLE
    LEVY, RA
    [J]. RADIOLOGY, 1995, 197 : 487 - 487
  • [10] Diffusion-Weighted 3D Multislab Echo Planar Imaging for High Signal-to-Noise Ratio Efficiency and Isotropic Image Resolution
    Engstroem, Mathias
    Skare, Stefan
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1507 - 1514