High-Resolution Magnetization-Prepared 3D-FLAIR Imaging at 7.0 Tesla

被引:97
|
作者
Visser, Fredy [1 ,2 ]
Zwanenburg, Jaco J. M. [1 ,4 ]
Hoogduin, Johannes M. [1 ,3 ]
Luijten, Peter R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, NL-3508 GA Utrecht, Netherlands
[2] Philips Healthcare, Best, Netherlands
[3] Univ Med Ctr Utrecht, Dept Neurol & Neurosurg, NL-3508 GA Utrecht, Netherlands
[4] Univ Med Ctr Utrecht, Image Sci Inst, NL-3508 GA Utrecht, Netherlands
关键词
magnetic resonance imaging; high field strength; 3D-FLAIR; high resolution; magnetization preparation; MULTIPLE-SCLEROSIS; PULSE GENERATION; IN-VIVO; FLAIR; SEQUENCES; MRI; FIELD;
D O I
10.1002/mrm.22397
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the present study is to develop a submillimeter volumetric (three-dimensional) fluid-attenuated inversion recovery sequence at 7T. Implementation of the fluid-attenuated inversion recovery sequence is difficult as increased T(1) weighting from prolonged T(1) constants at 7T dominate the desired T(2) contrast and yield suboptimal signal-to-noise ratio. Magnetization preparation was used to reduce T(1) weighting and improve the T(2) weighting. Also, practical challenges limit the implementation. Long refocusing trains with low flip angles were used to mitigate the specific absorption rate constraints. This resulted in a three-dimensional magnetization preparation fluid-attenuated inversion recovery sequence with 0.8 x 0.8 x 0.8 = 0.5 mm(3) resolution in a clinically acceptable scan time. The contrast-to-noise ratio between gray matter and white matter (contrast-to-noise ratio = signal-to-noise ratio [gray matter] signal-to-noise ratio [white matter]) increased from 12 +/- 9 without magnetization preparation to 28 +/- 8 with magnetization preparation (n = 12). The signal-to-noise ratio increased for white matter by 13 +/- 6% and for gray matter by 48 +/- 15%. In conclusion, three-dimensional fluid-attenuated inversion recovery with high resolution and full brain coverage is feasible at 7T. Magnetization preparation reduces the T(1) weighting, thereby improving the T(2) weighted contrast and signal-to-noise ratio. Magn Reson Med 64:194- 202, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:194 / 202
页数:9
相关论文
共 50 条
  • [1] Comparison between high-resolution 3D-IR with real reconstruction and 3D-flair sequences in the assessment of endolymphatic hydrops in 3 tesla
    Suarez Vega, Victor Manuel
    Dominguez, Pablo
    Caballeros Lam, Fanny Meylin
    Leal, Jose Ignacio
    Perez-Fernandez, Nicolas
    ACTA OTO-LARYNGOLOGICA, 2020, 140 (11) : 883 - 888
  • [2] Fast High-Resolution 3D Magnetization-Prepared GRE with Complementary Phase-Cycling Acquisitions
    Peng, Q.
    Zhao, Y.
    Wu, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E144 - E144
  • [3] Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
    de Graaf, Wolter L.
    Zwanenburg, Jaco J. M.
    Visser, Fredy
    Wattjes, Mike P.
    Pouwels, Petra J. W.
    Geurts, Jeroen J. G.
    Polman, Chris H.
    Barkhof, Frederik
    Luijten, Peter R.
    Castelijns, Jonas A.
    EUROPEAN RADIOLOGY, 2012, 22 (01) : 221 - 231
  • [4] Lesion detection at seven Tesla in multiple sclerosis using magnetisation prepared 3D-FLAIR and 3D-DIR
    Wolter L. de Graaf
    Jaco J. M. Zwanenburg
    Fredy Visser
    Mike P. Wattjes
    Petra J. W. Pouwels
    Jeroen J. G. Geurts
    Chris H. Polman
    Frederik Barkhof
    Peter R. Luijten
    Jonas A. Castelijns
    European Radiology, 2012, 22 : 221 - 231
  • [5] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    de Rotte, Alexandra A. J.
    van der Kolk, Anja G.
    Rutgers, Dik
    Zelissen, Pierre M. J.
    Visser, Fredy
    Luijten, Peter R.
    Hendrikse, Jeroen
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 2005 - 2011
  • [6] Feasibility of high-resolution pituitary MRI at 7.0 tesla
    Alexandra A. J. de Rotte
    Anja G. van der Kolk
    Dik Rutgers
    Pierre M. J. Zelissen
    Fredy Visser
    Peter R. Luijten
    Jeroen Hendrikse
    European Radiology, 2014, 24 : 2005 - 2011
  • [7] 3D Magnetization-Prepared Imaging Using a Stack-of-Rings Trajectory
    Wu, Holden H.
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (05) : 1210 - 1218
  • [8] Reduction of Oxygen-Induced CSF Hyperintensity on FLAIR MR Images in Sedated Children: Usefulness of Magnetization-Prepared FLAIR Imaging
    Jeong, H-K.
    Oh, S. W.
    Kim, J.
    Lee, S-K.
    Ahn, S. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (08) : 1549 - 1555
  • [9] 3-Tesla High-Resolution MR Imaging of the Wrist
    Saupe, Nadja
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2009, 13 (01) : 29 - 38
  • [10] 3D-FLAIR magnetic resonance imaging in the evaluation of mumps deafness
    Otake, Hironao
    Sugiura, Makoto
    Naganawa, Shinji
    Nakashima, Tsutomu
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2006, 70 (12) : 2115 - 2117