A novel transient rotor current control scheme of a doubly-fed induction generator equipped with superconducting magnetic energy storage for voltage and frequency support

被引:2
|
作者
Shen Yang-Wu [1 ]
Ke De-Ping [1 ]
Sun Yuan-Zhang [1 ]
Kirschen, Daniel [2 ]
Wang Yi-Shen [2 ]
Hu Yuan-Chao [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
基金
中国国家自然科学基金;
关键词
doubly-fed induction generator; transient rotor current control; superconducting magnetic energy storage; voltage support; RIDE-THROUGH STRATEGY; DFIG WIND TURBINES;
D O I
10.1088/1674-1056/24/7/070201
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A novel transient rotor current control scheme is proposed in this paper for a doubly-fed induction generator (DFIG) equipped with a superconducting magnetic energy storage (SMES) device to enhance its transient voltage and frequency support capacity during grid faults. The SMES connected to the DC-link capacitor of the DFIG is controlled to regulate the transient dc-link voltage so that the whole capacity of the grid side converter (GSC) is dedicated to injecting reactive power to the grid for the transient voltage support. However, the rotor-side converter (RSC) has different control tasks for different periods of the grid fault. Firstly, for Period I, the RSC injects the demagnetizing current to ensure the controllability of the rotor voltage. Then, since the dc stator flux degenerates rapidly in Period II, the required demagnetizing current is low in Period II and the RSC uses the spare capacity to additionally generate the reactive (priority) and active current so that the transient voltage capability is corroborated and the DFIG also positively responds to the system frequency dynamic at the earliest time. Finally, a small amount of demagnetizing current is provided after the fault clearance. Most of the RSC capacity is used to inject the active current to further support the frequency recovery of the system. Simulations are carried out on a simple power system with a wind farm. Comparisons with other commonly used control methods are performed to validate the proposed control method.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Composite frequency control strategy of doubly-fed induction generator wind turbines
    Zhu, X.-R., 1600, Power System Protection and Control Press (40):
  • [32] An improved fault current calculation method and protection scheme of Doubly-fed Induction Generator
    Yin, Jun
    ENERGY REPORTS, 2021, 7 : 5168 - 5174
  • [33] Flexible power control for rotor-side converter of doubly-fed induction generator under unbalanced voltage condition
    Ma J.
    Liu Q.
    Wu J.
    Sun F.
    Wang Y.
    Shen Y.
    Zhou N.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (02): : 196 - 203
  • [34] A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage
    Brekken, T
    Mohan, N
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 760 - 764
  • [35] Detecting Faults in Doubly Fed Induction Generator by Rotor Side Transient Current Measurement
    Stojcic, Goran
    Pasanbegovic, Kenan
    Wolbank, Thomas M.
    2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 4420 - 4425
  • [36] Detecting Faults in Doubly Fed Induction Generator by Rotor Side Transient Current Measurement
    Stojcic, Goran
    Pasanbegovic, Kenan
    Wolbank, Thomas M.
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (05) : 3494 - 3502
  • [37] Low Voltage Ride-Through Control of Doubly-Fed Induction Generator at Synchronism
    Binh, N. V.
    Hofmann, W.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 803 - 809
  • [38] Transient Coordination Control Strategy of Grid-friendly Doubly-fed Induction Generator
    Zhang L.
    Zhang C.
    Luo Y.
    Yao L.
    Qian M.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2019, 43 (12): : 44 - 50and112
  • [39] Control of a Doubly-fed Induction Generator with an Indirect Matrix Converter with Changing DC Voltage
    Reyes, E.
    Pena, R.
    Cardenas, R.
    Clare, J.
    Wheeler, P.
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 2010), 2010, : 1230 - 1235
  • [40] Comparison of Decoupling Structures in a Rotor Current Control of Doubly Fed Induction Generator
    Luszczyk, Tomasz
    Iwanski, Grzegorz
    2013 8TH INTERNATIONAL CONFERENCE AND EXHIBITION ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2013,