An improved fault current calculation method and protection scheme of Doubly-fed Induction Generator

被引:2
|
作者
Yin, Jun [1 ]
机构
[1] North China Univ Water Resources & Elect Power, Sch Elect Power, Zhengzhou, Peoples R China
关键词
Doubly fed Induction Generator (DFIG); Short-circuit current calculation; Rotor attenuation process; Relay protection; Protection scheme; POWER-CONTROL STRATEGY; SHORT-CIRCUIT CURRENT; DFIG WIND FARM; DISTANCE PROTECTION; SYSTEMS;
D O I
10.1016/j.egyr.2021.08.107
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Existing research on Doubly fed Induction Generator (DFIG) short-circuit current studies are based on hypothesis the rotor current is zero when the Crowbar is input after the fault, which ignores the impact of rotor current attenuation process. It would bring the error to the calculation results. To solve this problem, on the basis of analyzing variation process of DFIG's transient equivalent potential and the influence of rotor current attenuation process, the flux is calculated accurately. An accurate calculation equivalent model for DFIG short-circuit current is proposed. With the RTDS, an experiment platform with physical controller of converter is founded, the proposed model is validated. The effect of short circuit current to wind farms transmission line is studied, and an improved protection scheme is put forward. (C) 2021 Published by Elsevier Ltd.
引用
收藏
页码:5168 / 5174
页数:7
相关论文
共 50 条
  • [1] Crowbar Protection Scheme for Fault Ride Through in a Doubly-fed Induction Generator
    Seth, Sarthak
    Tharani, Kusum
    Banerjee, Sandeep
    Chhabra, Chaitanya
    Verma, Anshika
    Bhatia, Mridul
    [J]. ASIAN JOURNAL OF WATER ENVIRONMENT AND POLLUTION, 2023, 20 (05) : 33 - 37
  • [2] The Research on the Characteristic of Fault Current of Doubly-Fed Induction Generator
    Ao-Yang, Han
    Zhe, Zhang
    Xiang-Gen, Yin
    [J]. 2009 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), VOLS 1-7, 2009, : 947 - 950
  • [3] Protection Scheme Switch-Timing for Doubly-Fed Induction Generator during Fault Conditions
    Yang, Jin
    O'Reilly, John
    Fletcher, John E.
    [J]. 2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, : 1295 - +
  • [4] Short Circuit Current Calculation Method of Doubly-Fed Induction Generator with Crowbar Protection Based on Flux Transient Characteristics
    Ma, Jing
    Zhang, Weibo
    Zhao, Yu
    Song, Yubo
    Thorp, James S.
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (13) : 1426 - 1439
  • [5] Wind Turbine using Doubly-Fed Induction Generator Protection during Fault
    Ibrahima, Kone
    Zhao, Chengyong
    [J]. PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON INFORMATION, BUSINESS AND EDUCATION TECHNOLOGY (ICIBET 2013), 2013, 26 : 1330 - 1336
  • [6] Dynamic Performances and Protection Scheme for Doubly-Fed Induction Generator during Disturbances
    kairous, Djilali
    Wamkeue, Rene
    Belmadani, Bachir
    Benghanem, Mustapha
    [J]. PROCEEDINGS OF 14TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (EPE-PEMC 2010), 2010,
  • [7] A POWER CONTROL SCHEME FOR DOUBLY-FED INDUCTION GENERATOR
    Sguarezi Filho, Alfeu J.
    Oliveira Filho, M. E.
    Ruppert, Ernesto
    [J]. 2009 BRAZILIAN POWER ELECTRONICS CONFERENCE, VOLS 1 AND 2, 2009, : 1 - 8
  • [8] An Improved Droop Control Scheme of a Doubly-Fed Induction Generator for Various Disturbances
    Xu, Yien
    Chen, Pei
    Zhang, Xinsong
    Yang, Dejian
    [J]. ENERGIES, 2021, 14 (23)
  • [9] Fault Ride-Through of Doubly-Fed Induction Generator with Converter Protection Schemes
    Yang, Jin
    Dorrell, David G.
    Fletcher, John E.
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 1211 - +
  • [10] Generation of second harmonic component of fault current in a doubly-fed induction generator and mitigation measures for transformer protection
    Zheng, Tao
    Yan, Jingxian
    Li, Jing
    Wang, Xingguo
    Zhao, Hongcheng
    Wang, Sirui
    [J]. IET RENEWABLE POWER GENERATION, 2021, 15 (07) : 1345 - 1357